Liquiline System CA80SI provides precise online analysis of silica and helps protect plant equipment from glass-like deposits ensuring optimum performance of turbines and ion exchangers. Its unique combination of peristaltic and high-precision dispenser pumps enables extremely reliable operation and low maintenance. The silica analyzer offers advanced diagnostics and can be easily adapted to your process needs by retrofitting up to 6 channels and connecting up to 4 Memosens sensors.
Compare

Analyser

Measuring Principle Colorimetric
Characteristic Analyzer for silica in aqueous solutions
Measuring method Comply with standard colorimetric measuring principle - heteropoly blue method
Size Housing (open version):
793 x 530 x 417 mm
31.22 x 20.87 x 16.42 in
Housing (closed version):
793 x 530 x 463 mm
31.22 x 20.87 x 18.23 in
Housing with base:
1723 x 530 x 463 mm
67.83 x 20.87 x 18.23 in
Design Open design / cabinet
Plastic ASA-PC
Process temperature 5 to 45 °C (41 to 113 °F)
Ambient temperature 5 to 40 °C (41 to 104 °F)
Process pressure 1 to 5 bar (14.5 to 72.5 psi)
Sample flow rate 60 to 250 ml/min (2.03 to 8.45 fl.oz/min)
Consistency of the sample Particle free
Specials Easy upgrade to measuring station with up to four digital Memosens sensors
Automatic calibration and cleaning
User-configurable measuring, cleaning and calibration intervals
optional up to 6 sample channels
Flexible functionality and modular expandable
Digital communication for remote access
Application Determination of silica concentration in boiler feed water
Monitoring of water-steam-circuit and condensate
Monitoring and optimization of reverse osmosis and desalination
Power supply 100 to 120 VAC / 200 to 240 VAC ± 10%
50 ± 1 or 60 ± 1.2 Hz
Output / communication 2x 0/4 to 20 mA
Optional: Webserver, Modbus, Ethernet/IP, Profibus DP
Input 1, 2, 4 or 6 measuring channels
Optional 1 to 4 digital inputs for sensors with Memosens protocol
Measuring range 0 to 500 µg/l (ppb)
50 to 5000 µg/l (ppb)
Consumables Reagents and standard solutions CY80SI
Maintenance kit CAV800

Advantages

  • Protects expensive equipment in power plants: the silica analyzer monitors the silica concentration in the steam-water circuit, effectively preventing deposits on equipment surfaces.

  • Early online detection of critical silica concentrations ensures efficient power plant operation and optimizes maintenance and downtime.

  • Measurement based on the standard heteropoly blue method, directly comparable with laboratory results.

  • Maximum reliability: the unique combination of peristaltic pump and high-precision plunger pump provides stable measurement with low maintenance.

  • Optimized investment: up to 6 sample channels can be selected to meet changing process requirements at any time; connecting Memosens digital sensors allows easy upgrading to a complete measuring station.

  • Supports digital fieldbuses for seamless integration into process control systems, such as Modbus, EtherNet/IP or PROFIBUS.

  • In the event of an error, advanced diagnostics and web server remote access enable fast corrective action.

Application areas

  • The CA80SI silica analyzer monitors the silica concentration in the power industry and utilities.

  • Purity indicator for boiler feedwater and steam

  • Early warning of condenser leaks

  • Warning of ion exchanger depletion

Spare Parts & Accessories 81

81 spare parts · click to collapse
Order codeDescription
CY80SI-Reagent/Standard Solution CY80SIReagent set for CA80SI with long shelf life or standard solutionEnquire
CAV800-CAV800 Maintenance Tool KitKits with all maintenance parts for Liquiline System CA8x analyzers Content: dispensers, hoses, connectors, O-ring for the sample collector, filter mats. Optional: in-and outlet hoses(PA), Liquidmanager without motor (PT) or 2 sample collector beakers(PV)Enquire
71101762CM442/CM444/CM448/CSF48 display cable accessoryCM44x/CSF48/CA8xDetails
71218409CA8x Accessory: Door with WindowDetails
71218419CA8x accessory: M12 digital sensor external socketDetails
71218473CA8x accessories: analyzer standard configurationDetails
71218400CA8x/CAT860 Accessories: Wall MountingDetails
71218402CA8x/CAT860 accessory: baseDetails
71218425CA8x/CAT860 Accessory: Lock cylinderDetails
71218429CA8x/CAT860 Accessory: Door StopDetails
71408683CA80SI assembled capillary tube accessoryDetails
71408711Photometer cuvette accessory for CA80SIDetails
71411248Filter accessory for CA80SIDetails
71222107CA8x accessories: 20 pcs 2.5 ml syringe pumpsDetails
71222108CA8x accessory: 10 x 2.5 mL syringe pump mounting basesDetails
71404719Norprene tubing accessory, 15 m long, ID 1.6 mmDetails
71404721C-Flex tubing accessory, 7.5 m long, ID 3.2 mmDetails
71431075CA80COD waste valve tubeOnly use with new waste valve 71431077 Kit CA80COD: waste valve! For Kit CA80SI/82HA: Use as pump hose!Details
515058021 L black safety plastic bottleDetails
515058081 L clear plastic safety bottleDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Accessories / Spare parts

Source:Endress+Hauserpublic information from the website

4 models · click to collapse
All documents for this model
6 documents · click to expand
BA

Memosens Chinese

Rev. 0822 208 pages
Preview
BA

BA Liquiline System CA80SI Chinese

Rev. 0725 164 pages
Preview
BA

Memosens English

Rev. 0822 228 pages
Preview
BA

BA Liquiline System CA80SI English

Rev. 0725 178 pages
Preview
TI

TI Liquiline System CA80SI Chinese

Rev. 0725 32 pages
Preview
TI

TI Liquiline System CA80SI English

Rev. 0725 36 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · EH-ONLINE — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted EH-ONLINE properly configured on the existing plant, with the aim of continuous water monitoring on the E+H online platform.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the EH-ONLINE configuration has to involve configured under one numbering scheme across platform protocols and sensors.

Configuration

Supply and installation were organised through the online water-analysis line: integrating around each online monitoring point. On site this meant configured under one numbering scheme across platform protocols and sensors, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is data flows through the platform, improving service and diagnostics, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · EH-ONLINE — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous water monitoring on the E+H online platform.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means configured under one numbering scheme across platform protocols and sensors.

What We Did

We took a online water-analysis line approach — integrating around each online monitoring point. Delivery was built around configured under one numbering scheme across platform protocols and sensors, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — data flows through the platform, improving service and diagnostics, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · EH-ONLINE — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from EH-ONLINE, focusing on continuous water monitoring on the E+H online platform.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The EH-ONLINE specification must therefore cover configured under one numbering scheme across platform protocols and sensors.

Delivery Approach

Delivery was handled as the online water-analysis line — integrating around each online monitoring point. Execution centred on configured under one numbering scheme across platform protocols and sensors, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — data flows through the platform, improving service and diagnostics, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · EH-ONLINE — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is EH-ONLINE; the focus is continuous water monitoring on the E+H online platform.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with configured under one numbering scheme across platform protocols and sensors.

Implementation

The scope ran through the online water-analysis line: integrating around each online monitoring point. Technically it hinges on configured under one numbering scheme across platform protocols and sensors, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means data flows through the platform, improving service and diagnostics, which cut the workload on the site maintenance team.