Order Code:CLS50-13A9/0
Corresponding ext. order code:CLS50-A1B1
Name:Indumax CLS50
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | A | Non-hazardous area + UKCA marking |
| 020 | Process Connection | 1 | Thread G 3/4 |
| 030 | Sensor-; Seal-;Adapter material | B | PEEK; Viton; PEEK |
| 040 | Cable Connection | 1 | 5m fixed cable, max. 125oC |
Configuration Explained
This is a CLS50 toroidal conductivity sensor for the chemical industry, for non-hazardous areas, process connection G3/4 thread, adapter and seal in PEEK plus Viton, resistant to solvents and high temperatures, electrode 1.4571, 5 m fixed cable rated to 125 °C, PEEK resists swelling so it stays stable in long-term solvent immersion, easy to install and dismantle with common spare parts, suitable for conductivity measurement in small and medium chemical piping and bypass lines.