Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CLS50 Indumax

CLS50 Indumax
Indumax CLS50
Configurable Models 13 models
Indumax CLS50 is an inductive conductivity sensor for standard, hazardous and high-temperature applications. Benefit from high chemical resistance and long durability thanks to robust materials (PFA, PEEK). Moreover, it is insensitive to soiling and performs reliable and repeatable even in harsh and aggressive media. The wide temperature range of -20 to +180 °C leaves nothing to be desired.
Compare

Conductivity

Measuring Principle Inductive
Application Waste water, process
Characteristic Inductive conductivity cell made of highly resistant material for conductivity and concentration neasurements in process applications.
Measuring range 2µS/cm - 2000 mS/cm
Measuring principle Inductive conductivity measurement
Design - No direct contact with the media because of the sensor coating made of highly resistant material.
Material PEEK or PFA
Dimension Electrode: outside diameter: appr. 47 mm inside diameter: appr. 15 mm
Process temperature max. 180°C (PEEK)
(356°F)max. 125°C (PFA)
(254°F)
Process pressure max. 20 bar (PEEK)
(290 psi) max. 16 bar (PFA)
(233 psi)
Temperature sensor Integrated Pt100
Ex certification ATEX
Connection Process connection: NPT1", DN50, AINSI, JIScable: fixed cable connection.
Ingress protection IP67
Certificates, declarations and approvals Calibration certification of the cell constant.

The Indumax CLS50 is an inductive conductivity sensor used in standard, hazardous and high-temperature measurement applications. Made of robust materials (PFA, PEEK), it is resistant to chemical corrosion, durable and insensitive to contamination, and can be used for the reliable measurement of highly corrosive media with good repeatability. The temperature measuring range extends to -20...+180 °C.

 

Advantages

Durable, chemical-resistant, suitable for measurements under harsh operating conditions

Contamination-resistant materials prevent contamination

Wide temperature measuring range and corrosion-resistant materials make the sensor highly versatile

Robust design for long service life

Explosion protection approval

 

Areas of application

The Indumax CLS50 measures toroidal conductivity and is suitable for the following industries:

 

Chemical industry: - acid and alkali concentration measurement

- Quality monitoring of chemicals in tanks and pipes

Food&beverage industry:

- Phase separation between medium/medium mixtures in piping systems

Wastewater treatment plants:

- Inlet monitoring

Various explosion protection approvals such as ATEX, FM, CSA, NEPSI, suitable for explosive hazardous areas

Spare Parts & Accessories 20

20 spare parts · click to collapse
Order codeDescription
51500482CLS50 PTFE gasketContents: 2 pcs. PTFE gaskets, 1 pcs. 3/4" nut Max clamping torque of 20 NmDetails
71086368CLS50 CHEMRAZ O-ringDetails
51500481washerDetails
71086369Kit CLS50 >20081001: VITON O-ringDetails
51500483***CLS50 PTFE DN50 GasketDetails
71086372PTFE sealing ring CLS50 DN50Details
51500484washerDetails
71086374Kit CLS50 ANSI+JIS >20081001: PTFE gasketDetails
51500525CLS50 DN50 SS flangeDetails
51500527flangeDetails
51500934flangeDetails
51500935flangeDetails
51500936flangeDetails
51500937flangeDetails
51500753Cable accessories CLS50/52Details
50081902Calibration solution 74.0 µS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081903calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.Details
50081904Calibration solution 1.406 mS/cm500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081905calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails
50081906calibration solution500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISODetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

   

Measuring principle video

Click to play

   

Measuring principle video

Click to play

Source:Endress+Hauserwebsite public information

13 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA Indumax CLS50D/CLS50 Chinese

Rev. 2424 32 pages
Preview
BA

BA Indumax CLS50D/CLS50 English

Rev. 2424 36 pages
Preview
TI

TI Indumax CLS50D/CLS50 Chinese

Rev. 2226 20 pages
Preview
TI

TI Indumax CLS50D/CLS50 English

Rev. 2226 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · conductivity — Application Case

Customer Profile

The typical setting in Municipal Wastewater Treatment is the inlet, biological and outlet stages of a municipal plant. The measuring point is conductivity; the focus is measuring conductivity to judge water purity or chemical concentration.

Key Difficulties

Conditions are high solids and corrosive fractions, with large diurnal flow swings and, on top of that, effluent parameters drift and probes foul with sludge and biofilm, which a standard configuration cannot handle for long. The design therefore starts with choosing two- or four-electrode cells by range and corrosivity.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing two- or four-electrode cells by range and corrosivity, and on these requirements: stable compliance with Grade 1A discharge limits and online data reporting.

Customer Benefit

In practice this means stable concentration control and less reagent and discharge waste, which cut the workload on the site maintenance team.

Food & Beverage

Food & Beverage · conductivity — Application Case

Project Background

The project covers dosing, pasteurising, filling and CIP stages. The work centres on conductivity and the core task is measuring conductivity to judge water purity or chemical concentration.

Operating Challenges

The medium and duty are characterised by syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. So conductivity cannot be specified generically — it calls for choosing two- or four-electrode cells by range and corrosivity.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing two- or four-electrode cells by range and corrosivity, with these requirements in view: food-safety and hygienic design per 3-A / EHEDG.

Results

Since start-up the system has run steadily; the practical result is stable concentration control and less reagent and discharge waste.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · conductivity — Application Case

Project Overview

The site is reactors, metering vessels and finished-product tanks. The customer wanted conductivity properly configured on the existing plant, with the aim of measuring conductivity to judge water purity or chemical concentration.

Technical Challenges

What actually causes trouble is highly corrosive media with solvents and crystallisation, partly in explosive atmospheres, and corrosion plus Ex protection shortens instrument life and makes downtime costly. All of this means the conductivity configuration has to involve choosing two- or four-electrode cells by range and corrosivity.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing two- or four-electrode cells by range and corrosivity, checked line by line against: Ex certification and GMP traceability of records.

Performance

After commissioning the outcome is stable concentration control and less reagent and discharge waste, and the readings are now used for process tuning.

Power & Energy

Power & Energy · conductivity — Application Case

Site Conditions

This is a Power & Energy customer whose plant is at boiler feedwater, turbine condensate and FGD/DeNOx systems. The main task was measuring conductivity to judge water purity or chemical concentration.

The Problem

The difficulty lies in high temperature and pressure with both steam and saline water; at the same time drift under high temperature and pressure, with very costly unplanned outages. Specification therefore means choosing two- or four-electrode cells by range and corrosivity.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing two- or four-electrode cells by range and corrosivity, with point-by-point checks on: compliance with power-industry codes and unit availability targets.

Operating Outcome

In service the system performs as intended — stable concentration control and less reagent and discharge waste, with routine maintenance falling noticeably.