The multiparameter handheld enables you to check any measuring point in your plant with Memosens sensors with inductive coupling. Using the identical sensors as already installed at the fixed measuring points in your process guarantees full data consistency between your measurements. Via a uniquely secure Bluetooth connection you can transfer all sensor data and measured values to your tablets or smartphones which makes documentation, sensor adjustment and data transfer safe and effortless.
Compare

Conductivity

Measuring Principle Conductive
Application Multiparameter mobile device for field and laboratory use
Characteristic Connectable to all pH, conductivity and dissolved oxygen Memosens sensors
Design Small and handy - designed to fit in your pocket
Material Housing: PBT
Display: PMMA
Buttons, cap: TPE
M12 connector: CuZn, nickel-plated
Dimension 84 x 54 x 47 mm (h x w x d)
3.31 x 2.13 x 1.85 inch (h x w x d)
Ingress protection IP 66
Input One channel instrument with inductive Memosens coupling
M12 connector for using CYK10 and CYK20 Memosens cable
Output / communication Bluetooth

Oxygen

Measuring Principle Amperometric oxygen measurement
Application Multiparameter mobile device for field and laboratory use
Characteristic Connectable to all pH, conductivity and dissolved oxygen Memosens sensors
Design Small and handy - designed to fit in your pocket
Material Housing: PBT
Display: PMMA
Buttons, cap: TPE
M12 connector: CuZn, nickel-plated
Dimension 84 x 54 x 47 mm (h x w x d)
3.31 x 2.13 x 1.85 inch (h x w x d)
Ingress protection IP 66
Input One channel instrument with inductive Memosens coupling
M12 connector for using CYK10 and CYK20 Memosens cable
Output / communication Bluetooth

pH

Measuring Principle Potentiometric
Application Multiparameter mobile device for field and laboratory use
Characteristic Connectable to all pH, conductivity and dissolved oxygen Memosens sensors
Design Small and handy - designed to fit in your pocket
Material Housing: PBT
Display: PMMA
Buttons, cap: TPE
M12 connector: CuZn, nickel-plated
Dimension 84 x 54 x 47 mm (h x w x d)
3.31 x 2.13 x 1.85 inch (h x w x d)
Ingress protection IP 66
Input One channel instrument with inductive Memosens coupling
M12 connector for using CYK10 and CYK20 Memosens cable
Output / communication Bluetooth

The multiparameter handheld device checks the various measuring points in your plant by connecting Memosens digital sensors. Thanks to Memosens technology, the measurement data are fully consistent as long as the sensor parameters of the portable device and the field sensors are identical. Using the unique, secure Bluetooth connection, you can transfer all sensor data and measured values to a tablet or smartphone to easily and safely archive records, adjust sensors and transfer data.

Benefits

  • Simple operation:

  • Operate and configure the device using your existing tablet or smartphone.

  • Benefit from Memosens technology:

  • Memosens digital sensors provide data transmission with the highest level of safety, maximum measured-value stability and utmost convenience.

  • Measurement results you can trust:

  • Process, laboratory and sampling measurements all use the same technology, so the results are fully consistent.

  • Simplified daily work:

  • Precalibrated Memosens digital sensors support hot plugging and allow rapid switching of measured parameters.

  • Data logger function:

  • Stores more than 10,000 measured values, including the time information of each value.

  • Easy to carry:Flexible use that meets both laboratory and process requirements. Small and lightweight for convenient portability.

  • Charging:Low battery? Charge the device via the inductive charging station.

Application areas

  • The Liquiline Mobile CML18 multiparameter handheld device can be used to measure the following parameters:

  • pH/ORP, temperature

  • Conductivity or trace conductivity, temperature

  • Dissolved oxygen or trace dissolved oxygen, temperature

  • It is suitable for all industries and their utility applications and can accurately check:

  • Measuring points

  • Samples (on site and in the laboratory)

  • Process points that are not measured online

Spare Parts & Accessories 6

6 spare parts · click to collapse
Order codeDescription
71468656CML18 Wired ChargerDetails
71468661***CML18 Wireless ChargerDetails
71530939CML18 protective housingDetails
71496600Kit CML18 M12-USB Data + Charging CableDetails
CYK20-Cable CYK20Memosens cable lab- and portable applications for Memosens plug-in head sensors. Connection for ex- and non hazardous sensors. Memobase Plus lab tool No connection to field transmitters ::Thin and flexible ::Optimum for lab applicationEnquire
CYK10-Digital electrode cable CYK10Application: digital sensors with inductive Memosens plug-head Working limit: max. -20...135oCEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

Source: public information from the Endress+Hauser website

12 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA Liquiline Mobile CML18 Chinese

Rev. 0624 92 pages
Preview
BA

BA Liquiline Mobile CML18 English

Rev. 0624 96 pages
Preview
TI

TI Liquiline Mobile CML18 Chinese

Rev. 0325 28 pages
Preview
TI

TI Liquiline Mobile CML18 English

Rev. 0325 28 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · EH-Lab — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on EH-Lab and the core task is water and process analysis with E+H laboratory instruments.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So EH-Lab cannot be specified generically — it calls for configured by parameter set, range and calibration practice.

Solution

The Ainstru engineering team worked through the laboratory line: configuring around lab method standards and sample throughput. The configuration involves configured by parameter set, range and calibration practice, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is consistent with online instruments, making cross-checks easy.

Food & Beverage

Food & Beverage · EH-Lab — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted EH-Lab properly configured on the existing plant, with the aim of water and process analysis with E+H laboratory instruments.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the EH-Lab configuration has to involve configured by parameter set, range and calibration practice.

Configuration

Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant configured by parameter set, range and calibration practice, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is consistent with online instruments, making cross-checks easy, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · EH-Lab — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was water and process analysis with E+H laboratory instruments.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by parameter set, range and calibration practice.

What We Did

We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around configured by parameter set, range and calibration practice, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — consistent with online instruments, making cross-checks easy, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · EH-Lab — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from EH-Lab, focusing on water and process analysis with E+H laboratory instruments.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The EH-Lab specification must therefore cover configured by parameter set, range and calibration practice.

Delivery Approach

Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on configured by parameter set, range and calibration practice, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — consistent with online instruments, making cross-checks easy, with confidence in this measuring point improving markedly.