Technical Data
CompareConductivity
| Measuring Principle | Conductive |
| Application | Multiparameter mobile device for field and laboratory use |
| Characteristic | Connectable to all pH, conductivity and dissolved oxygen Memosens sensors |
| Design | Small and handy - designed to fit in your pocket |
| Material | Housing: PBT Display: PMMA Buttons, cap: TPE M12 connector: CuZn, nickel-plated |
| Dimension | 84 x 54 x 47 mm (h x w x d) 3.31 x 2.13 x 1.85 inch (h x w x d) |
| Ingress protection | IP 66 |
| Input | One channel instrument with inductive Memosens coupling M12 connector for using CYK10 and CYK20 Memosens cable |
| Output / communication | Bluetooth |
Oxygen
| Measuring Principle | Amperometric oxygen measurement |
| Application | Multiparameter mobile device for field and laboratory use |
| Characteristic | Connectable to all pH, conductivity and dissolved oxygen Memosens sensors |
| Design | Small and handy - designed to fit in your pocket |
| Material | Housing: PBT Display: PMMA Buttons, cap: TPE M12 connector: CuZn, nickel-plated |
| Dimension | 84 x 54 x 47 mm (h x w x d) 3.31 x 2.13 x 1.85 inch (h x w x d) |
| Ingress protection | IP 66 |
| Input | One channel instrument with inductive Memosens coupling M12 connector for using CYK10 and CYK20 Memosens cable |
| Output / communication | Bluetooth |
pH
| Measuring Principle | Potentiometric |
| Application | Multiparameter mobile device for field and laboratory use |
| Characteristic | Connectable to all pH, conductivity and dissolved oxygen Memosens sensors |
| Design | Small and handy - designed to fit in your pocket |
| Material | Housing: PBT Display: PMMA Buttons, cap: TPE M12 connector: CuZn, nickel-plated |
| Dimension | 84 x 54 x 47 mm (h x w x d) 3.31 x 2.13 x 1.85 inch (h x w x d) |
| Ingress protection | IP 66 |
| Input | One channel instrument with inductive Memosens coupling M12 connector for using CYK10 and CYK20 Memosens cable |
| Output / communication | Bluetooth |
The multiparameter handheld device checks the various measuring points in your plant by connecting Memosens digital sensors. Thanks to Memosens technology, the measurement data are fully consistent as long as the sensor parameters of the portable device and the field sensors are identical. Using the unique, secure Bluetooth connection, you can transfer all sensor data and measured values to a tablet or smartphone to easily and safely archive records, adjust sensors and transfer data.
Benefits
-
Simple operation:
-
Operate and configure the device using your existing tablet or smartphone.
-
Benefit from Memosens technology:
-
Memosens digital sensors provide data transmission with the highest level of safety, maximum measured-value stability and utmost convenience.
-
Measurement results you can trust:
-
Process, laboratory and sampling measurements all use the same technology, so the results are fully consistent.
-
Simplified daily work:
-
Precalibrated Memosens digital sensors support hot plugging and allow rapid switching of measured parameters.
-
Data logger function:
-
Stores more than 10,000 measured values, including the time information of each value.
-
Easy to carry:Flexible use that meets both laboratory and process requirements. Small and lightweight for convenient portability.
-
Charging:Low battery? Charge the device via the inductive charging station.
Application areas
-
The Liquiline Mobile CML18 multiparameter handheld device can be used to measure the following parameters:
-
pH/ORP, temperature
-
Conductivity or trace conductivity, temperature
-
Dissolved oxygen or trace dissolved oxygen, temperature
-
It is suitable for all industries and their utility applications and can accurately check:
-
Measuring points
-
Samples (on site and in the laboratory)
-
Process points that are not measured online
Spare Parts & Accessories 6
6 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71468656 | CML18 Wired Charger | Details |
| 71468661 | ***CML18 Wireless Charger | Details |
| 71530939 | CML18 protective housing | Details |
| 71496600 | Kit CML18 M12-USB Data + Charging Cable | Details |
| CYK20- | Cable CYK20Memosens cable lab- and portable applications for Memosens plug-in head sensors. Connection for ex- and non hazardous sensors. Memobase Plus lab tool No connection to field transmitters ::Thin and flexible ::Optimum for lab application | Enquire |
| CYK10- | Digital electrode cable CYK10Application: digital sensors with inductive Memosens plug-head Working limit: max. -20...135oC | Enquire |
Configurator / Comparison
Source: public information from the Endress+Hauser website
Manuals & Documents 4
All documents for this modelProduct Videos
Case Studies
Municipal Wastewater Treatment · EH-Lab — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on EH-Lab and the core task is water and process analysis with E+H laboratory instruments.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So EH-Lab cannot be specified generically — it calls for configured by parameter set, range and calibration practice.
Solution
The Ainstru engineering team worked through the laboratory line: configuring around lab method standards and sample throughput. The configuration involves configured by parameter set, range and calibration practice, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is consistent with online instruments, making cross-checks easy.
Food & Beverage · EH-Lab — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted EH-Lab properly configured on the existing plant, with the aim of water and process analysis with E+H laboratory instruments.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the EH-Lab configuration has to involve configured by parameter set, range and calibration practice.
Configuration
Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant configured by parameter set, range and calibration practice, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is consistent with online instruments, making cross-checks easy, and the readings are now used for process tuning.
Chemical & Pharmaceutical · EH-Lab — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was water and process analysis with E+H laboratory instruments.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by parameter set, range and calibration practice.
What We Did
We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around configured by parameter set, range and calibration practice, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — consistent with online instruments, making cross-checks easy, with routine maintenance falling noticeably.
Power & Energy · EH-Lab — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from EH-Lab, focusing on water and process analysis with E+H laboratory instruments.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The EH-Lab specification must therefore cover configured by parameter set, range and calibration practice.
Delivery Approach
Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on configured by parameter set, range and calibration practice, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — consistent with online instruments, making cross-checks easy, with confidence in this measuring point improving markedly.
Related Products
Endress+HauserMemosens Lab Cable CYK20
Endress+HauserLiquiline To Go CYM290
Endress+HauserLiquiline To Go Ex CYM291
Endress+HauserMemosens CPL51E
Endress+HauserTurbimax CUE25, Handheld Infrared
Endress+HauserTurbimax CUE23, Laboratory Infrared
Endress+HauserZero-point gel COY8
Endress+Hauser