Technical Data
CompareTurbidity
| Measuring Principle | |
| Application | Turbidimeter for laboratory measurement |
| Characteristic | " Versions with infrared light source " Auto ranging 0 ... 1000 NTU " Automatic alert when calibration is needed " Simple calibration procedures " RS-232 output for printing or recording of measured values " Reusable calibration standards |
| Measuring range | 0 - 1000 NTU |
| Measuring principle | Turbidity measurement using standardised 90° scattered light method acc. to ISO 7027/EN27027(Infrared Light) |
| Design | The transmitted infrared light beam is scattered by the solid matter particles in the medium. The scattered light beams are detected by scattered light receivers which are arranged at an angle of 90° to the light source. |
| Material | Housing: ABS Sample cuvette: Borosilicate glass |
| Dimension | 95 x 254 x 273 mm / 3.75 x 10 x 10.75 inches |
| Process temperature | 0 ... 50 °C / 32 ... 122 °F |
| Process pressure | Ambient pressure |
| Output / communication | Uni-directional RS-232 output for recorder |
Product Overview
The Turbimax CUE23 is a reliable turbidity meter for random-sample water turbidity measurement compliant with EN ISO 7027. It provides users with online verification of turbidity values and laboratory-based process control. Simple operation: take a sample in the container, place it in the measuring chamber and read the turbidity value. In addition, the Turbimax CUE23 provides calibration guidance according to preset standards, simplifying maintenance.
-
Advantages
-
Convenient verification of the entire process
-
Convenient verification of the online measuring loop
-
Calibration according to predefined standards
-
Areas of application
-
The Turbimax CUE23 is a laboratory turbidity meter:
-
Drinking and process water:
-
Verification of the treatment process
-
Verification of the online measuring loop
-
Water quality monitoring in waterworks and supply networks
-
Utilities:
-
Verification of the treatment process
-
Verification of the online measuring loop
-
The Turbimax CUE23 measures in compliance with EN ISO 7027
Spare Parts & Accessories 3
3 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71030108 | Lighting moduleLight source: Infrared LED (850 nm) Spare part: turbidity measurement | Details |
| 51518580 | CUE21/CUE23/CUE24 Calibration KitReady-for-use solutions: 0,02 NTU, 10 NTU and 1000 NTU Accessory turbidity measurement | Details |
| 51518581 | Sample measuring glass tube for CUE23/CUE24incl. caps, 3 pcs. Accessory turbidity measurement | Details |
Configurator / Comparison
Source:Endress+Hauserwebsite public information
Manuals & Documents 2
All documents for this modelCase Studies
Municipal Wastewater Treatment · EH-Lab — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on EH-Lab and the core task is water and process analysis with E+H laboratory instruments.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So EH-Lab cannot be specified generically — it calls for configured by parameter set, range and calibration practice.
Solution
The Ainstru engineering team worked through the laboratory line: configuring around lab method standards and sample throughput. The configuration involves configured by parameter set, range and calibration practice, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is consistent with online instruments, making cross-checks easy.
Food & Beverage · EH-Lab — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted EH-Lab properly configured on the existing plant, with the aim of water and process analysis with E+H laboratory instruments.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the EH-Lab configuration has to involve configured by parameter set, range and calibration practice.
Configuration
Supply and installation were organised through the laboratory line: configuring around lab method standards and sample throughput. On site this meant configured by parameter set, range and calibration practice, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is consistent with online instruments, making cross-checks easy, and the readings are now used for process tuning.
Chemical & Pharmaceutical · EH-Lab — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was water and process analysis with E+H laboratory instruments.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means configured by parameter set, range and calibration practice.
What We Did
We took a laboratory line approach — configuring around lab method standards and sample throughput. Delivery was built around configured by parameter set, range and calibration practice, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — consistent with online instruments, making cross-checks easy, with routine maintenance falling noticeably.
Power & Energy · EH-Lab — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from EH-Lab, focusing on water and process analysis with E+H laboratory instruments.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The EH-Lab specification must therefore cover configured by parameter set, range and calibration practice.
Delivery Approach
Delivery was handled as the laboratory line — configuring around lab method standards and sample throughput. Execution centred on configured by parameter set, range and calibration practice, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — consistent with online instruments, making cross-checks easy, with confidence in this measuring point improving markedly.
Related Products
Endress+HauserMemosens Lab Cable CYK20
Endress+HauserLiquiline To Go CYM290
Endress+HauserLiquiline Mobile CML18
Endress+HauserLiquiline To Go Ex CYM291
Endress+HauserMemosens CPL51E
Endress+HauserTurbimax CUE25, Handheld Infrared
Endress+HauserZero-point gel COY8
Endress+Hauser