Product family:
Memosens CPF81E
pH electrodeIn Stock (8)
Memosens CPF81E;Approval Non-hazardous area;Electrode Type Basic version, process connection NPT 3/4", zero point pH 7,0, temperature sensor NTC 30k;Application Range 0–11 pH, 0…80oC, 0,8…11 bar (abs)
Order Code:CPF81E-AA5NAD1|CPF81E-10E3/0
Name:Memosens CPF81E
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 020 | Electrode Type | 5 | Basic version, process connection NPT 3/4", zero point pH 7,0, temperature sensor NTC 30k |
| 030 | Application Range | N | 0–11 pH, 0…80oC, 0,8…11 bar (abs) |
| 040 | Reference System | AD | PTFE ring junction, double chamber, 3 M KNO3, 3 M KCl, Ag/AgCl |
| 045 | Insertion Length | 1 | 23mm, bulb membrane, electrode guard |
Configuration Explained
This is a CPF81E pH electrode, for non-hazardous areas, basic version, NPT3/4 process connection, zero point pH7, with NTC30k temperature sensor, range 0 to 11pH, withstands 0 to 80°C, 0.8 to 11bar, PTFE annular diaphragm dual-chamber reference, 3M KNO3 and KCl, Ag/AgCl system, insertion depth 23mm, bulb membrane with protection, suitable for online pH measurement in wastewater and general water treatment.