Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CPS72D CeragelDiscontinued

CPS72D Ceragel
Ceragel CPS72DDiscontinued
Configurable Models 1 models
Ceragel CPS72D is the digital specialist for demanding processes and hygienic applications. Its contamination-resistant gel guarantees stable measurement even in flowing media or low conductivity. The sensor measures reliably at high temperatures and is non-toxic assuring highest safety. Ceragel CPS72D is not the latest Memosens generation. To get information on the new Memosens CPS72E sensor with extended functionality, click here.
Compare

ORP / Redox

Measuring Principle
Application - Hygiene and sterile applications.- Pharmaceuticals, biotechnology, fermenters, contaminating media.
Characteristic - Digital electrode with Memosens-Technology.- Gel-compact-electrode with ceramic diaphragm.- Platinum-cap- CIP/SIP and autoclavable- high accuracy
Measuring range -1500mV - +1500mV
Measuring principle - ceramic diaphragm- double chamber and double gel reference- Platinum-ring
Dimension Diameter : 12mmShaft length : 120,225,360mm
Process temperature -15°C - 140°C
Process pressure max. 16bar
Ex certification ATEX
FM
CSA
Connection Inductive transmission of digital measuring signals.
Ingress protection IP68
Certificates, declarations and approvals EHEDG

 

Measuring Principle Sensor ORP / Redox
Application - Hygiene and sterile applications.- Pharmaceuticals, biotechnology, fermenters, contaminating media.
Characteristic - Digital electrode with Memosens-Technology.- Gel-compact-electrode with ceramic diaphragm.- Platinum-cap- CIP/SIP and autoclavable- high accuracy
Measuring range -1500mV - +1500mV
Measuring principle - ceramic diaphragm- double chamber and double gel reference- Platinum-ring
Dimension Diameter : 12mmShaft length : 120,225,360mm
Process temperature -15°C - 140°C
Process pressure max. 16bar
Ex certification ATEX
FM
CSA
 
Connection Inductive transmission of digital measuring signals.
Ingress protection IP68
Additional certifications EHEDG

Measuring principle video

Click to play

Spare Parts & Accessories 4

4 spare parts · click to collapse
Order codeDescription
71038228*** sensorfor assignment of sensors to measuring loop. 100 sensor clips with printable labelsDetails
71538217CPSxx electrode protection cap20 pc protective caps for pH sensors CPSxxDetails
CPY4-KCl electrolyte CPY4For liquid filled electrodesEnquire
CPY3-ORP calibration solution CPY3TechnicalEnquire

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products
1 models · click to collapse
All documents for this model
6 documents · click to expand
BA

BA CPSx1, CPFx1 pH电极 CPSx2, CPFx2 ORP电极 Chinese

Rev. 0426 20 pages
Preview
BA

BA CPSx1, CPFx1 pH sensors CPSx2, CPFx2 ORP sensors English

Rev. 0426 20 pages
Preview
BA

pH-/Redoxsensoren und Referenzhalbzellen pH/ORP sensors and reference half cells Operating Instructions English

Rev. 0217 16 pages
Preview
TI

技术资料 Ceragel CPS72, CPS72D Chinese

Rev. 1313 12 pages
Preview
TI

Technical Information Ceragel CPS72 and CPS72D English

Rev. 1313 12 pages
Preview
TI

Technical Information Ceragel CPS72 / CPS72D English

12 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · ORP — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted ORP properly configured on the existing plant, with the aim of measuring redox potential to control disinfection and oxidation.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the ORP configuration has to involve choosing fouling-resistant electrodes and reference systems by medium contamination.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing fouling-resistant electrodes and reference systems by medium contamination, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is oxidant dosing with a real basis, avoiding excess and residue, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · ORP — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was measuring redox potential to control disinfection and oxidation.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing fouling-resistant electrodes and reference systems by medium contamination.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing fouling-resistant electrodes and reference systems by medium contamination, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — oxidant dosing with a real basis, avoiding excess and residue, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · ORP — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from ORP, focusing on measuring redox potential to control disinfection and oxidation.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The ORP specification must therefore cover choosing fouling-resistant electrodes and reference systems by medium contamination.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing fouling-resistant electrodes and reference systems by medium contamination, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — oxidant dosing with a real basis, avoiding excess and residue, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · ORP — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is ORP; the focus is measuring redox potential to control disinfection and oxidation.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing fouling-resistant electrodes and reference systems by medium contamination.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing fouling-resistant electrodes and reference systems by medium contamination, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means oxidant dosing with a real basis, avoiding excess and residue, which cut the workload on the site maintenance team.