 CPS96D

Memosens CPS96D

CPS96D Memosens glass electrode, used for measuring heavily polluted media in chemical processes, paper or paint production
Compare

pH

Measuring Principle
Application - Process applications - media with high contamination: emulsions, suspensions, precipitation reactions - min. conductivity >500µS/cm
Characteristic - Rapid response - new, stabilised gel insensitive to contaminations
Measuring range pH 0-14
Measuring principle - Open aperture - double gel reference with ion trap
Pt-disc as additional ORP element.
rH measurment and control of the reference impedance.
Design - All shaft lengths with temperature sensor - advanced gel technology - digital electrode with Memosens technology
Material Glass
Dimension Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)
Process temperature max. 110°C
(230°F)
Process pressure max. 10 bar
(145 psi)
Temperature sensor NTC 30k
Connection Inductive, contactless connection head with Memosens technology
Ingress protection IP68

pH:

Measuring Principle Potentiometric
Application - Process applications - media with high contamination: emulsions, suspensions, precipitation reactions - min. conductivity >500µS/cm
Characteristic - Rapid response - new, stabilised gel insensitive to contaminations
Measuring range pH 0-14
Measuring principle - Open aperture - double gel reference with ion trap Pt-disc as additional ORP element. rH measurment and control of the reference impedance.
Design - All shaft lengths with temperature sensor - advanced gel technology - digital electrode with Memosens technology
Material Glass
Dimension Diameter: 12 mm (0.46 inch)
Shaft lengths: 120, 225, 360 and 425 mm
(4.68, 8.77, 14.04 and 16,57 inch)
Process temperature max. 110°C
(230°F)
Process pressure max. 10 bar
(145 psi)
Temperature sensor NTC 30k
Connection Inductive, contactless connection head with Memosens technology
Ingress protection IP68
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · ORP Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · ORP Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · ORP Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · ORP Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of ORP.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable ORP for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.