Order Code:CUS50D-12J4/0
Corresponding ext. order code:CUS50D-AA2BA4A1
Name:Turbimax CUS50D
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 020 | Application/Measuring Range | 2 | Absorption (ISO 7027) |
| 030 | Process Connection | B | Clamp 2" |
| 040 | Adaption Cable | A | Fixed cable, crimp sleeves |
| 050 | Cable Length | 4 | 15m |
| 060 | Sensor Material | A | Head: PCTFE, shaft: 1.4571 |
| 070 | Seal Material | 1 | EPDM |
Configuration Explained
This is a CUS50D turbidity sensor, Memosens digital, measures turbidity, suspended solids concentration and absorbance, for use in non-hazardous areas, ISO7027 absorbance method, 2 inch clamp connection, 15m fixed cable with terminals, head PCTFE, shaft 1.4571, EPDM seal, long cable for easy routing, on-site installation is simple, low routine maintenance, suitable for high turbidity monitoring in wastewater plants.