Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

CUS50D Turbimax

CUS50D Turbimax
Turbimax CUS50D
Configurable Models 5 models
Turbimax CUS50D is a smart sensor that allows unattended operation in a wide range of industrial wastewater and process applications. Its absorption principle enables single-point-calibration. Choose from different integrated analytical models to adapt the sensor to your specific application. With Memosens digital technology, Turbimax CUS50D combines maximum process and data integrity with simple operation. It resists corrosion and enables lab calibration.
Compare

Total Solids / Total Suspended Solids

Measuring Principle Absorption
Application Absorption sensor for turbidity and suspended solids measurements in industrial wastewater and processes
Installation Insitu (immersion in process or retractable assembly)
Design 40 mm sensor
Dimension 209.5 x 40 mm (8.25 x 1.57 inch)
Material Sensor head: PCTFE
Sensor shaft: 1.4571 stainless steel (316TI) or plastic (PPS GF40)
O-ring: EPDM
Measuring range 40 to 4 000 FAU
0 to 60 g/L suspended solids
0 to 10 OD
Process pressure 0.5 to 4.5 bar (7.3 to 65.3 psi) absolute
Connection G1, NPT3/4
Ingress protection IP68

Turbidity

Measuring Principle Absorption
Application Absorption sensor for turbidity and suspended solids measurements in industrial wastewater and processes
Installation Insitu (immersion in process or retractable assembly)
Measuring range 40 to 4 000 FAU
0 to 60 g/L suspended solids
0 to 10 OD
Measuring principle Absorption
Design 40 mm sensor
Material Sensor head: PCTFE
Sensor shaft: 1.4571 stainless steel (316TI) or plastic (PPS GF40)
O-ring: EPDM
Dimension 209.5 x 40 mm (8.25 x 1.57 inch)
Process temperature Process temperature -20 to 85 °C (-4 to 185 °F)
Ambient temperature -20 to 60 °C (-4 to 140 °F)
Process pressure 0.5 to 4.5 bar (7.3 to 65.3 psi) absolute
Connection G1, NPT3/4
Ingress protection IP68

The Turbimax CUS50D intelligent sensor is widely used in many industrial wastewater and process applications and measures without attenuation. The absorbance principle allows single-point calibration. Select the sensor by referring to various comprehensive analysis models to meet the specific application requirements of the user. With Memosens digital technology, the Turbimax CUS50D is easy to operate and offers the highest process safety and the highest data integrity. Corrosion-resistant and suitable for laboratory calibration.

Benefits
High measuring accuracy and repeatability ensure stable measurement results across the medium-to-high turbidity measuring range
High resistance to chemical corrosion and low maintenance workload: anti-fouling sensor head made of Teflon
The plastic sensor is robust and can measure in corrosive media or seawater
Fast and simple commissioning: the sensor is pre-calibrated for a wide range of applications and can be easily adjusted by single-point calibration
The fully automatic sludge measuring mode optimizes the signal channel selection for all types of sludge
Excellent process adaptability: can be installed in various Endress+Hauser mounting assemblies for rapid sensor positioning

Applications
The Turbimax CUS50D measures turbidity, suspended solids concentration and absorbance:
Industrial wastewater and utilities: 
- Solids content measurement in process and wastewater sludge
- Determination of flocculant dosage by absorbance measurement
- Measurement of wastewater concentration in dairies
Process media: 
Concentration measurement of process media, e.g. titanium dioxide
Highly absorbent media:
Concentration measurement of dark media, e.g. in the fourth cleaning stage of wastewater treatment plants

 

Spare Parts & Accessories 10

10 spare parts · click to collapse
Order codeDescription
71241882CUS52D: 2x chuck sealFor CUS50D, CUS52D, CUA252 and CUA262Details
71242180blind coverFor CUS50D, CUS52D, CUA252 and CUA262Details
71395617CUS50D spare parts, air cleaning headDetails
71072583*** cleaning unit, 230V air compressorDetails
71194623Output Air PurificationDetails
71400898CUS50D spare parts, solid-state reference accessoryDetails
71242201clamp ringDetails
71361175CxS5xD Spare Parts: Threadlocker 20 mlDetails
71420151Kit CYA251 sensor adapter CUS50DDetails
71093377Mounting accessoriesfast sensor assemblyDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

A

A

   

Measurement principle video

Click to play

Source: Endress+Hauserpublic information from the website

5 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA Turbimax CUS50D Chinese

Rev. 0524 48 pages
Preview
BA

BA Turbimax CUS50D English

Rev. 0524 52 pages
Preview
TI

TI Turbimax CUS50D Chinese

Rev. 0625 20 pages
Preview
TI

TI Turbimax CUS50D English

Rev. 0625 20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · turbidity — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on turbidity and the core task is measuring turbidity as an indicator of suspended solids and filtration.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So turbidity cannot be specified generically — it calls for choosing 90° scatter or surface scatter by range, with de-bubbling.

Solution

The Ainstru engineering team worked through the analyser range: selecting as part of a complete water-analysis system. The configuration involves choosing 90° scatter or surface scatter by range, with de-bubbling, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is backwashing triggered by water quality, saving water while holding quality.

Food & Beverage

Food & Beverage · turbidity — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted turbidity properly configured on the existing plant, with the aim of measuring turbidity as an indicator of suspended solids and filtration.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the turbidity configuration has to involve choosing 90° scatter or surface scatter by range, with de-bubbling.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing 90° scatter or surface scatter by range, with de-bubbling, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is backwashing triggered by water quality, saving water while holding quality, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · turbidity — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was measuring turbidity as an indicator of suspended solids and filtration.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing 90° scatter or surface scatter by range, with de-bubbling.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing 90° scatter or surface scatter by range, with de-bubbling, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — backwashing triggered by water quality, saving water while holding quality, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · turbidity — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from turbidity, focusing on measuring turbidity as an indicator of suspended solids and filtration.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The turbidity specification must therefore cover choosing 90° scatter or surface scatter by range, with de-bubbling.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing 90° scatter or surface scatter by range, with de-bubbling, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — backwashing triggered by water quality, saving water while holding quality, with confidence in this measuring point improving markedly.