FMP51 Levelflex
Levelflex FMP51
Configurable Models 4 models
Levelflex FMP51 for level measurement even under extreme process conditions like high temperature and high pressure in the process industry. FMP51 offers maximum reliability even in case of moved surface and foam or when numerous tank baffles interfere with the measurement. Levelflex FMP51 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Compare

Continuous / Liquids

Measuring Principle Guided radar
Characteristic / Application Premium device
Rod probe, Rope probe, Coaxial probe
Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias.
Interface measurement Clean interfaces liquid/ liquid;
Simultaneous measurement of interface and overall level
Specialities Heartbeat Technology,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
HistoROM,
RFID TAG for easy identification
Supply / Communication 2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional)
Accuracy Rod probe :+/- 2 mm (0.08 in)
Rope probe 15 m (49 ft): +/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)
Ambient temperature -50...+80 °C
(-58...+176 °F)
Process temperature -50...+200 °C
(-58...+392 °F)
Process pressure / max. overpressure limit Vacuum...40 bar
(Vacuum...580 psi)
Main wetted parts Rod probe:
316L, Alloy C, Ceramic
Rope probe:
316, 316L, Alloy C, Ceramic
Coaxial probe:
316L, Alloy C, Ceramic, PFA
Process connection Thread:
G3/4...G1 1/2;
MNPT 3/4...MNPT1 1/2
Flange:
ASME 1 1/2"...8",
DN50...DN 200,
JIS 10K
Sensor length Rod probe: 10 m (33 ft)
Rope probe: 45 m (148 ft)
Coaxial probe: 6 m (20 ft)
Max. measurement distance Rod: 10 m (33 ft) Min DK>1.6
Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6;
30m...45 m (98ft...148 ft) Min DK>1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4
Communication 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology
Certificates / Approvals ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
Safety approvals Overfill protection WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
ASME B31.1, B31.3
AD2000
Marine approval GL/ ABS/ LR/ BV/ DNV
Options Sensor remote with 3 m/ 9 ft cable,
Gas-tight feed through,
Remote operation via SmartBlue App using Bluetooth®

The Levelflex FMP51 is used for level measurement under extreme conditions in the process industry, such as high temperature and high pressure. Even with a fluctuating surface, foam formation or interference from obstacles inside the tank, the FMP51 maintains the most stable measured values. The Levelflex FMP51 is used for continuous level measurement and interface measurement of liquids, pastes and slurries. The measured value is unaffected by changes in the medium, temperature, gas blanket or vapor.

 

Benefits

Reliable measurement even under changing product or process conditions

HistoROM integrated data storage unit for fast and convenient commissioning, maintenance and diagnostics

Innovative multi-echo tracking technology for highly reliable measurement results

Hardware and software developed in accordance with IEC 61508, up to SIL3

Heartbeat Technology for efficient and safe plant operation throughout the entire life cycle

Seamless integration into control or asset management systems with an intuitive, guided operating concept (on site or via the control system)

Certified by world-renowned SIL and WHG tests, saving you time and money

 

Application areas

Available for rod, cable or coaxial probe measurement.

 

Process connection: from ¾" thread or flange

Temperature: -40 to +200 °C (-40 to +392 °F)

Pressure: -1 to +40 bar (-14.5 to +580 psi)

Maximum measuring range: rod 10 m (33 ft), cable 45 m (148 ft), coaxial probe 6 m (20 ft)

Accuracy: ±2 mm (0.08")

International explosion protection approval, WHG overflow protection, SIL, marine approval, 5-point linearity protocol

Spare Parts & Accessories 110

110 spare parts · click to collapse
Order codeDescription
71115174Housing filter plug 316L, GT18, 1 setConsists of: 2x filter plug metall 316L. 1x pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71115175Housing Filter Plug (Brass/Nickel)Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71115176housing fixing clipUsage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71110281Aluminum coverMaterial: 316L. O-ring, EPDM, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71110282Aluminum coverMaterial: 316L. O-ring NBR, PTFE coated. Usage: FMP51/FMP52/FMP54/FMP55/ FMP56/FMP57, FMR51/FMR52/FMR53/ FMR54/FMR57, FMR62/FMR67, FHX50. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71110292Aluminum coverMaterial: plastics PBT-FR sight glas PC. O-ring EPDM, PTFE coated. Usage: FHX50, FMP50/FMP51/FMP52/ FMP53/FMP54/FMP55/FMP56/FMP57, FMR50/ FMR51/FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.Details
71110293Aluminum coverMaterial: plastics PBT, metallized. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.Details
71110297Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71110299Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71383631housingMaterial: 316L. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200.Details
71383666housingMaterial: 316L. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200.Details
71383674housingMaterial: Alu. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200.Details
71383675housingMaterial: Alu. O-Ring FVMQ. Usage: FMP51/FMP54, FMR51/FMR52/FMR54. Usage: Prowirl 200.Details
71110284Aluminum coverMaterial: 316L. O-ring EPDM /PTFE coated. Usage: terminal compartment Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71110291Aluminum coverMaterial: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP51/FMP52/FMP54/FMP55/FMP56/FMP57, FMR51/FMR52/FMR53/FMR54/FMR57, FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Prowirl 200.Details
71110295Aluminum coverMaterial: plastics PBT, metallized. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67.Details
71110301Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71110302Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200.Details
71185516CoverMaterial: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57, FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Prowirl 200.Details
71185517Aluminum coverMaterial: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Measuring principle video

Click to play
4 models · click to collapse
Diagnostic codes(42 条)→
All documents for this model
12 documents · click to expand
BA

BA Levelflex FMP51, FMP52, FMP54 HART Chinese

HART Rev. 2524 222 pages
Preview
BA

Levelflex FMP51, FMP52, FMP54 PROFIBUS PA 操作手册 Chinese

PROFIBUS-PA Rev. 1818 222 pages
Preview
BA

BA Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus Chinese

FOUNDATION-Fieldbus Rev. 0924 224 pages
Preview
BA

BA Levelflex FMP51 Modbus Chinese

Modbus Rev. 0324 184 pages
Preview
BA

BA Levelflex FMP51, FMP52, FMP54 PROFIBUS PA English

PROFIBUS-PA Rev. 2124 210 pages
Preview
BA

Levelflex FMP51, FMP52, FMP54 HART Operating Instructions English

HART Rev. 2118 256 pages
Preview
BA

Levelflex / Levelflex M Zentrierscheibe / Centering disk (PFA) Mounting Instructions English

Rev. 1717 8 pages
Preview
BA

Accessory English

Rev. 1414 9 pages
Preview
BA

Accessory English

Rev. 1108 5 pages
Preview
BA

BA Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus English

FOUNDATION-Fieldbus Rev. 0924 236 pages
Preview
BA

BA Levelflex FMP51 Modbus English

Modbus Rev. 0324 194 pages
Preview
TI

TI Levelflex FMP51, FMP52, FMP54 Chinese

Rev. 3225 108 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · guided wave radar — Application Case

Project Background

The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on guided wave radar and the core task is level and interface measurement along a guided probe or cable.

Operating Challenges

The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So guided wave radar cannot be specified generically — it calls for choosing rod or cable by dielectric constant, range and agitation.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing rod or cable by dielectric constant, range and agitation, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.

Results

Since start-up the system has run steadily; the practical result is works even with low-dielectric media, with a small dead zone and high accuracy.

Food & Beverage

Food & Beverage · guided wave radar — Application Case

Project Overview

The site is dosing, pasteurising, filling and CIP stages. The customer wanted guided wave radar properly configured on the existing plant, with the aim of level and interface measurement along a guided probe or cable.

Technical Challenges

What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the guided wave radar configuration has to involve choosing rod or cable by dielectric constant, range and agitation.

Configuration

Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing rod or cable by dielectric constant, range and agitation, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.

Performance

After commissioning the outcome is works even with low-dielectric media, with a small dead zone and high accuracy, and the readings are now used for process tuning.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · guided wave radar — Application Case

Site Conditions

This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was level and interface measurement along a guided probe or cable.

The Problem

The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing rod or cable by dielectric constant, range and agitation.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing rod or cable by dielectric constant, range and agitation, with point-by-point checks on: Ex certification and GMP traceability of records.

Operating Outcome

In service the system performs as intended — works even with low-dielectric media, with a small dead zone and high accuracy, with routine maintenance falling noticeably.

Power & Energy

Power & Energy · guided wave radar — Application Case

Application Context

boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from guided wave radar , focusing on level and interface measurement along a guided probe or cable.

Process Constraints

drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The guided wave radar specification must therefore cover choosing rod or cable by dielectric constant, range and agitation.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing rod or cable by dielectric constant, range and agitation, together with compliance with power-industry codes and unit availability targets.

Field Results

Operation shows the benefit clearly — works even with low-dielectric media, with a small dead zone and high accuracy, with confidence in this measuring point improving markedly.