Technical Data
CompareContinuous / Liquids
| Measuring Principle | Guided radar |
| Characteristic / Application | Premium device. Hygiene Rod probe, ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head. |
| Specialities | Heartbeat Technology, Bluetooth® commissioning, Operation and maintenance SmartBlue App, HistoROM, RFID TAG for easy identification |
| Supply / Communication | 2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) Bluetooth® wireless technology and App (optional) |
| Accuracy | Rod probe:+/- 2 mm (0.08 in) |
| Ambient temperature | -20...+80 °C (-4...+176 °F) |
| Process temperature | -20...+150 °C (-4...+302 °F) |
| Process pressure / max. overpressure limit | Vacuum...16 bar (Vacuum...232 psi) |
| Main wetted parts | Rod probe: 304, 304L, 316L, PEEK |
| Process connection | Thread: M24 |
| Process connection hygienic | Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS |
| Sensor length | Rod probe: 6 m (20 ft) |
| Max. measurement distance | Rod: 6 m (20 ft) Min DK>1.6 |
| Communication | 4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology |
| Certificates / Approvals | ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex |
| Safety approvals | Overfill protection WHG SIL |
| Design approvals | EN 10204-3.1 |
| Hygienic approvals | 3A, EHEDG CoC ASME-BPE |
| Options | Sensor remote with 3 m/9 ft or 6 m/18 ft cable, Weld-in adpater, Remote operation via SmartBlue App using Bluetooth® |
The Levelflex FMP53 is used for continuous level measurement in the food and life sciences industries with high hygienic requirements. The FMP53 complies with the hygienic requirements of ASME BPE and USP Class VI. The FMP53 does not need to be removed from the process and can be cleaned in place, offering a unique cost advantage. Even with a fluctuating surface, foam formation, medium changes or clogged nozzles, the FMP53 maintains the most stable measured values.
Benefits
Reliable measurement even under changing product or process conditions
HistoROM integrated data storage unit for fast and convenient commissioning, maintenance and diagnostics
Innovative multi-echo tracking technology for highly reliable measurement results
Hardware and software developed in accordance with IEC 61508, up to SIL3
Heartbeat Technology ensures high cost efficiency and safe plant operation throughout the entire life cycle
Seamless integration into control or asset management systems with an intuitive, guided menu operating concept (on site or via the control system)
Certified by world-renowned SIL and WHG tests, saving you time and money
Application areas
Available with rod connection.
Process connection: for hygienic requirements (clamp connection, 11851, 11864, NEUMO, Varivent N, SMS)
Temperature: -20 to +150 °C (-4 to +302 °F)
Pressure: -1 to +16 bar (-14.5 to +232 psi)
Maximum measuring range: rod 6 m (20 ft)
Accuracy: ±2 mm (0.12")
International explosion protection approval, WHG overflow protection, SIL, hygienic approval, 5-point linearity protocol
Spare Parts & Accessories 93
93 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 71115175 | Housing Filter Plug (Brass/Nickel)Consists of: 2x filter plug brass nickel, pressure compensation filter. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71115176 | housing fixing clipUsage: housing GT18/GT19/GT20, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71185516 | CoverMaterial: 316L. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMP54/FMP56/FMP57, FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Prowirl 200. | Details |
| 71110293 | Aluminum coverMaterial: plastics PBT, metallized. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. | Details |
| 71185518 | CoverMaterial: plastic PBT, metallizied. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. | Details |
| 71110297 | Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71110299 | Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71110292 | Aluminum coverMaterial: plastics PBT-FR sight glas PC. O-ring EPDM, PTFE coated. Usage: FHX50, FMP50/FMP51/FMP52/ FMP53/FMP54/FMP55/FMP56/FMP57, FMR50/ FMR51/FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. | Details |
| 71110295 | Aluminum coverMaterial: plastics PBT, metallized. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. | Details |
| 71110301 | Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71110302 | Aluminum coverMaterial: aluminium, coated. O-ring EPDM, PTFE coated. Usage: terminal compartment Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71185517 | Aluminum coverMaterial: aluminium. O-ring EPDM, PTFE coated. Usage: terminal compartment, for overvoltage protection, not for Ex d/XP, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, FMR50/FMR51/FMR52/FMR53/ FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71110303 | Housing seal kitConsists of: O-ring 88.5x3.53 EPDM/PTFE, cover electronics compartment, housing GT19. O-Ring 88.5x3.53 NBR, cover electronics compartment, housing GT18, GT20. O-ring 91.67x3.53 EPDM/PTFE, cover terminal compartment, housing GT19. O-Ring 91.67x3.53 NBR, cover terminal compartment, housing GT18, GT20. O-ring 50.39x3.53 EPDM/PTFE, housing/sensor. FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. Usage: Promass 200/TB2, Prosonic Flow 200, Promag 200, Prowirl 200. | Details |
| 71450381 | M12 connector, IP66/68 NEMA 4X/6P, Pro TOFFor electrical connection. Usage: FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57,FMR50/FMR51/FMR52/FMR53/ FMR54/FMR57, FMR60/FMR62/FMR67. | Details |
| XPF0001- | Guided Wave Radar Levelflex FMP5x Electronics ModuleMain electronics. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57. | Enquire |
| XPF0001- | Guided Wave Radar Levelflex FMP5x Electronics ModuleMain electronics. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57. | Enquire |
| 71108591 | ***I/O module Level, 2-wire, 4-20 mA, HART, Ex, LP, V1Version 1. Not for Ex d/XP. LP=low powered. 1x current output HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57. | Details |
| 71187812 | I/O moduleVersion 2. Not for Ex d/XP. LP=low powered. 1x current output HART. Usage: FMP50/FMP51/FMP52/FMP53/FMP54/ FMP55/FMP56/FMP57, FMR50/FMR51/FMR52/ FMR53/FMR54/FMR56/FMR57, FMR60/FMR62/FMR67. | Details |
| 71108594 | I/O moduleNon-Ex, Ex. 1x current output HART. Version 2. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57, FMR50/FMR51/ FMR52/FMR53/FMR54/FMR56/FMR57. | Details |
| 71108591 | ***I/O module Level, 2-wire, 4-20 mA, HART, Ex, LP, V1Version 1. Not for Ex d/XP. LP=low powered. 1x current output HART. Usage: FMP50/FMP51/FMP52/FMP53/ FMP54/FMP55/FMP56/FMP57. | Details |
Configurator / Comparison
Measuring principle video
Click to playManuals & Documents 10
All documents for this model10 documents · click to expand
BA Levelflex FMP53 HART Chinese
Levelflex FMP53 PROFIBUS PA 操作手册 Chinese
BA Levelflex FMP53 FOUNDATION Fieldbus Chinese
BA Levelflex FMP53 HART English
BA Levelflex FMP53 PROFIBUS PA English
Levelflex FMP53 FOUNDATION Fieldbus Operating Instructions English
TI 焊接接头、过程转接头和法兰 Chinese
TI Levelflex FMP53 Chinese
TI Weld-in adapter, process adapter and flanges English
TI Levelflex FMP53 English
Product Videos
Case Studies
Municipal Wastewater Treatment · guided wave radar — Application Case
Project Background
The project covers the inlet, biological and outlet stages of a municipal plant. The work centres on guided wave radar and the core task is level and interface measurement along a guided probe or cable.
Operating Challenges
The medium and duty are characterised by high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. So guided wave radar cannot be specified generically — it calls for choosing rod or cable by dielectric constant, range and agitation.
Solution
The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing rod or cable by dielectric constant, range and agitation, with these requirements in view: stable compliance with Grade 1A discharge limits and online data reporting.
Results
Since start-up the system has run steadily; the practical result is works even with low-dielectric media, with a small dead zone and high accuracy.
Food & Beverage · guided wave radar — Application Case
Project Overview
The site is dosing, pasteurising, filling and CIP stages. The customer wanted guided wave radar properly configured on the existing plant, with the aim of level and interface measurement along a guided probe or cable.
Technical Challenges
What actually causes trouble is syrups, dairy and beverages that scale easily, under strict hygienic requirements, and frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. All of this means the guided wave radar configuration has to involve choosing rod or cable by dielectric constant, range and agitation.
Configuration
Supply and installation were organised through the level range: level solution matched to the actual tank and silo geometry. On site this meant choosing rod or cable by dielectric constant, range and agitation, checked line by line against: food-safety and hygienic design per 3-A / EHEDG.
Performance
After commissioning the outcome is works even with low-dielectric media, with a small dead zone and high accuracy, and the readings are now used for process tuning.
Chemical & Pharmaceutical · guided wave radar — Application Case
Site Conditions
This is a Chemical & Pharmaceutical customer whose plant is at reactors, metering vessels and finished-product tanks. The main task was level and interface measurement along a guided probe or cable.
The Problem
The difficulty lies in highly corrosive media with solvents and crystallisation, partly in explosive atmospheres; at the same time corrosion plus Ex protection shortens instrument life and makes downtime costly. Specification therefore means choosing rod or cable by dielectric constant, range and agitation.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing rod or cable by dielectric constant, range and agitation, with point-by-point checks on: Ex certification and GMP traceability of records.
Operating Outcome
In service the system performs as intended — works even with low-dielectric media, with a small dead zone and high accuracy, with routine maintenance falling noticeably.
Power & Energy · guided wave radar — Application Case
Application Context
boiler feedwater, turbine condensate and FGD/DeNOx systems is a typical Power & Energy duty. The project started from guided wave radar , focusing on level and interface measurement along a guided probe or cable.
Process Constraints
drift under high temperature and pressure, with very costly unplanned outages, and high temperature and pressure with both steam and saline water only amplify it. The guided wave radar specification must therefore cover choosing rod or cable by dielectric constant, range and agitation.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing rod or cable by dielectric constant, range and agitation, together with compliance with power-industry codes and unit availability targets.
Field Results
Operation shows the benefit clearly — works even with low-dielectric media, with a small dead zone and high accuracy, with confidence in this measuring point improving markedly.
Related Products
Endress+HauserLevelflex FMP50
Endress+HauserLevelflex FMP54
Endress+HauserLevelflex FMP57
Endress+HauserLevelflex FMP55
Endress+HauserLevelflex FMP52
Endress+HauserLevelflex FMP51
Endress+HauserLevelflex FMP56