Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTL325N Nivotester

FTL325N Nivotester
Nivotester FTL325N
Endress+Hauser FTL325N
Configurable Models 3 models
Nivotester FTL325N is a switching unit for point level detection in liquid tanks, also in hazardous explosion areas. Also suitable for overfill prevention in tanks with combustible or non-combustible liquids harmful to water. Two-point control and point level detection. The perfect fit for applications in safety related systems with requirements for functional safety up to SIL2 in accordance to IEC 61508 /IEC 61511 using Liquiphant with electronic insert FEL56 or FEL58.
Compare

Point Level / Liquids

Measuring Principle Vibration Liquids
Characteristic / Application Switching unit NAMUR technology for rail mounting
SIL2, according 61511
Intrinsically safe
Supply / Communication NAMUR
24V AC,DC / 230V AC
Ambient temperature Single installation:
-20 °C ... 60 °C
(-4 °F ... 140 °F)
Rail mounting:
-20 °C ... 50 °C
(-4 °F ... 122 °F)
Communication 1 Channel: 1 level SPDT + 1 alarm SPST
3 Channel: 3 level SPDT + 1 alarm SPST
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO, NEPSI, EAC
Safety approvals Overfill prevention WHG
SIL

Point Level / Solids

Measuring Principle Vibration Solids
Characteristic / Application Switching unit NAMUR technology for rail mounting
SIL2, according 61511
Intrinsically safe
Supply / Communication NAMUR
24V AC,DC / 230V AC
Ambient temperature Single installation:
-20 °C ... 60 °C
(-4 °F ... 140 °F)
Rail mounting:
-20 °C ... 50 °C
(-4 °F ... 122 °F)
Communication 1 Channel: 1 level SPDT + 1 alarm SPST
3 Channel: 3 level SPDT + 1 alarm SPST
Certificates / Approvals ATEX, FM, CSA, IEC Ex, INMETRO NEPSI
Safety approvals Overfill prevention WHG
SIL

The Nivotester FTL325N switch unit is used for point level detection in liquid tanks, is suitable for hazardous areas and can also be used for overfill protection of tanks containing toxic, flammable or non-flammable liquids. With two-point control and point level detection, it is perfectly suited to safety-related systems. When used together with Liquiphant with FEL56 or FEL58 electronic inserts, it complies with IEC 61508/IEC 61511 and meets SIL2 functional safety requirements.

 

Advantages

The Nivotester FTL325N can be connected to 1, 2 or 3 measuring elements (1, 2 or 3-channel device)

The intrinsically safe signal circuit reaches EEx ia level and can be used in hazardous areas

Online monitoring ensures functional safety up to SIL2

The DIN rail housing facilitates side-by-side installation on the standard rail of a switch box

Pluggable terminal module, simple wiring

The NAMUR interface complies with EN 50227 (DIN 19234; NAMUR) or IEC 60947-5-6, for connecting NAMUR sensors or electronic inserts

 

Application

The switch unit uses NAMUR input and can be rail-mounted or installed separately.

Ambient temperature: -20 to +50 °C (-4 to +122°F)

International explosion protection certification; suitable for overfill protection of tanks containing toxic, flammable or non-flammable liquids; suitable for marine use

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Measuring principle video

Click to play
3 models · click to collapse
All documents for this model
8 documents · click to expand
BA

Nivotester FTL325N(三通道型) Chinese

Rev. 0220 48 pages
Preview
BA

Nivotester FTL325N(单通道型) 操作手册 Chinese

Rev. 0119 28 pages
Preview
BA

Nivotester FTL325N, 3-channel English

Rev. 0220 48 pages
Preview
BA

Nivotester FTL325N, single-channel Operating Instructions English

Rev. 0119 28 pages
Preview
TI

Nivotester FTL325N Chinese

Rev. 1520 20 pages
Preview
TI

技术资料 Nivotester FTL325N Chinese

Rev. 0303 16 pages
Preview
TI

Nivotester FTL325N English

Rev. 1520 20 pages
Preview
TI

Nivotester FTL 325 N Technical Information English

16 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · tuning fork — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was vibrating-fork point level detection and high/low alarms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing fork length and surface finish by density and stickiness.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing fork length and surface finish by density and stickiness, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no calibration needed, with dependable switching, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · tuning fork — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from tuning fork, focusing on vibrating-fork point level detection and high/low alarms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The tuning fork specification must therefore cover choosing fork length and surface finish by density and stickiness.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing fork length and surface finish by density and stickiness, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no calibration needed, with dependable switching, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · tuning fork — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is tuning fork; the focus is vibrating-fork point level detection and high/low alarms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing fork length and surface finish by density and stickiness.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing fork length and surface finish by density and stickiness, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no calibration needed, with dependable switching, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · tuning fork — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on tuning fork and the core task is vibrating-fork point level detection and high/low alarms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So tuning fork cannot be specified generically — it calls for choosing fork length and surface finish by density and stickiness.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing fork length and surface finish by density and stickiness, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no calibration needed, with dependable switching.