Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTL41 Liquiphant

FTL41 Liquiphant
Liquiphant FTL41
Configurable Models 8 models
Over 6 million installed Liquiphant point level switches in the field worldwide prove the day-to-day realiability of this device. With its active sensor technology you always be sure that your device is working correctly. In addition there is no need of adjustment to different media.
Compare

Point Level / Liquids

Measuring Principle Vibration Liquids
Characteristic / Application Compact vibronic device with an optional pipe extension up to 2 m;
Modular housing concept;
Wide range of certificates
Specialities RFID TAG for easy identification,
Plug and play functionalities
Supply / Communication 10...55V / DC-PNP 3-wire
19...253V AC or 19...55V DC / relays
NAMUR
Ambient temperature -40 °C...+70 °C
(-40 °F...+158 °F)
Process temperature -40 °C...+150 °C
(-40 °F...+302 °F)
Process pressure / max. overpressure limit Vacuum...40 bar
(Vacuum...580 psi)
Min. density of medium 0.5 g/cm³
(0.4 g/cm³ optional)
Main wetted parts 316L
Process connection Threads:
G3/4A, G1A, R3/4", R1, NPT3/4, NPT1
Flanges:
DN25...DN100
ASME 1"...4"
JIS 25A...50A
Process connection hygienic Tri-Clamp ISO2852
Sensor length Up to 2 m
Communication DC-PNP 3-wire
Relays
NAMUR
Certificates / Approvals ATEX, IEC Ex, CSA, NEPSI
Safety approvals Overfill protection WHG
Design approvals EN 10204-3.1
ASME B31.3 Process Piping
CRN
Marine approval ABS/ LR/ BV/ DNV
Components FTL325N Interface NAMUR

More than 6 million Liquiphant limit switches have been successfully and reliably in operation worldwide. The design without mechanical moving parts effectively eliminates the risk of mechanical failure and ensures stable operation. In addition, the device does not need to be configured separately for different media.

Advantages
One measuring system meets the measuring requirements of all liquids. No mechanical moving parts, plug-and-play, easy to use
Compared with float level switches, no mechanical moving parts and higher long-term stability
High switch point repeatability
Suitable for all pumpable liquids
Maintenance-free

Application
Limit switch with extension tube, suitable for limit detection of all kinds of liquids.
Process connections: threaded, flanged and hygienic connections (Tri-Clamp)
Temperature range: -40...+150°C (-40...+302°F)
Pressure range: -1...+40 bar (-14.5...+580 psi)
Sensor material: 316L
International explosion protection and WHG approvals

 

Spare Parts & Accessories 56

56 spare parts · click to collapse
Order codeDescription
XPF0040-Liquiphant 2-wire platform housingUsage: FTL41, FTL51B, FTL62, FTL63, FTL64.Enquire
71432590Electronic insert FEL42, PNP 10-55 VDC, 3-wire. Suitable for model: FTL41.3-wire. Usage: FTL41.Details
71432594Electronic plug-in module FEL44, relay DPDT 19-253VAC/19-55VDC, contact19-253VAC/19-55VDC, contact 253V/6A. Usage: FTL41.Details
71432595Electronic module FEL48 NAMUR 2-wire, for NAMUR H-L signal, suitable for model: FTL42-wire, NAMUR H-L signal. Usage: FTL41.Details
71435116Housing cover, aluminum, sealed cover, O-ring, HNBR. Suitable for models: FMG50, FTL41, FTLSealing ring, HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435118Housing cover, aluminum, closed cover, Ex d seal, HNBR. Suitable for: FMG50, FTL4Sealing ring, HNBR. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, NMT81, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435126Housing cover, plastic, sealed cover, O-ring, EPDM. Applicable models: FTL41, FTL51B.Sealing ring, EPDM. Usage: FMR54B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64.Details
71439089Aluminum cover with glass viewing windowSealing ring: HNBR. Sight glass: plastic. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, NMT81, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B, QWX43.Details
71550061Cover, plastic, sight windowSealing ring: EPDM. Sight glass: Polycarbonat. Usage: FHX50B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64.Details
71435135Cable gland M20, plastic, suitable for models: FTL41, FTL51B, PMC51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMB70, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMP50, PMP51B, PMP63B, PMP71B.Details
71435136Cable gland M20, nickel-plated brass, suitable for: FMG50, FTL41, FTL51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71440660M20x1.5-G1/2 adapter, aluminumConsists of: Adapter set, O-ring, 17.0 x 2.0 PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71462833M20x1.5-G1/2 adapter, plasticUsage: FTL41, FTL51B, FTL62, FTL63, FTL64.Details
71462835M20x1.5 to 1/2" NPT adapter, plasticUsage: FTL41, FTL51B, FTL62, FTL63, FTL64.Details
71589844Ground terminal LiquiphantConsists of: spring washer, screw, Earth handle, clamp. Usage: Only for switch electronics. Usage: FTL41, FTL51B, FTL62, FTL63, FTL64.Details
71647970Ground terminal, plastic housing, Liquiphant ESConsists of: spring washer, screw, grounding bracket. Usage: Only for switch electronics. Usage: FTL41, FTL51B, FTL62, FTL63, FTL64.Details
71647972Ground terminal, hygienic housing, Liquiph. ESConsists of: spring washer, screw, clamp strap. Usage: Only for switch electronics. Usage: FTL41, FTL51B, FTL62, FTL63, FTL64.Details
71435131Sealing ring EPDM, 5 pcs. Applicable models: FTL41, FTL51B, PMC51B, PMUsage: FHX50B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64.Details
71435132Seal ring HNBR, -40 °C, 5 pcs. Suitable for models: FMG50, FTL41, FTL5Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B,PMD75B, PMD78B, PMP51B, PMP71B.Details
71671700Locking screw, electronics compartment coverConsists of: 3x screw M4x5 and pin 29,9. Usage: Cover closed, electronics room single and dual compartment, or connection room dual compartment L-shape. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

   

Measuring principle video

Click to play

Source:Endress+Hauserwebsite public information

8 models · click to collapse
All documents for this model
6 documents · click to expand
BA

BA Liquiphant FTL41 Chinese

Rev. 0625 36 pages
Preview
BA

BA Liquiphant FTL41 English

Rev. 0625 40 pages
Preview
TI

TI 焊接接头、过程转接头和法兰 Chinese

Rev. 2726 130 pages
Preview
TI

TI Liquiphant FTL41 Chinese

Rev. 0625 40 pages
Preview
TI

TI Weld-in adapter, process adapter and flanges English

Rev. 2726 132 pages
Preview
TI

TI Liquiphant FTL41 English

Rev. 0625 40 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · tuning fork — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was vibrating-fork point level detection and high/low alarms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing fork length and surface finish by density and stickiness.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing fork length and surface finish by density and stickiness, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no calibration needed, with dependable switching, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · tuning fork — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from tuning fork, focusing on vibrating-fork point level detection and high/low alarms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The tuning fork specification must therefore cover choosing fork length and surface finish by density and stickiness.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing fork length and surface finish by density and stickiness, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no calibration needed, with dependable switching, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · tuning fork — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is tuning fork; the focus is vibrating-fork point level detection and high/low alarms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing fork length and surface finish by density and stickiness.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing fork length and surface finish by density and stickiness, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no calibration needed, with dependable switching, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · tuning fork — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on tuning fork and the core task is vibrating-fork point level detection and high/low alarms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So tuning fork cannot be specified generically — it calls for choosing fork length and surface finish by density and stickiness.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing fork length and surface finish by density and stickiness, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no calibration needed, with dependable switching.