Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTL375P NivotesterDiscontinued

FTL375P Nivotester
Nivotester FTL375PDiscontinued
Endress+Hauser FTL375P
The switching unit FTL375P is used for point level detection in liquid tanks and bulk material silos, also in hazardous explosion areas. Also suitable for liquid detection in pipes for dry running protection for pumps and overfill prevention for tanks with combustible or non-combustible liquids harmful to water. Up to 3 measuring devices for two-point control and point level detection. Functional safety up to SIL3 in accordance to IEC 61508 using Liquiphant with electronic insert FEL57.
Compare

Point Level / Liquids

Measuring Principle
Characteristic / Application Level isolating switching amplifier
Function is monitored
SIL2/3 according to IEC61508/61511 (FDIS)
19" circuit board
Up to 3 measuring devices possible
Supply / Communication PFM
Relay
Ambient temperature -20 °C ... 70 °C
(-4 °F ... 158 °F)
Communication Up to 3 relays and 3 transistor outputs
Certificates / Approvals ATEX, TIIS
Safety approvals Overfill prevention WHG
SIL

Point Level / Solids

Measuring Principle
Characteristic / Application Level isolating switching amplifier
unction is monitored
9" circuit board
Supply / Communication PFM
Relay
Ambient temperature -20 °C ... 70 °C
(-4 °F ... 158 °F)
Communication Up to 3 relays and 3 transistor outputs
Certificates / Approvals ATEX, TIIS
Safety approvals Overfill prevention WHG
SIL

The FTL375P switching unit is used for limit detection in liquid tanks and solid silos and can be used in hazardous areas. It is also suitable for liquid detection in pipes, for dry-run protection of pumps, and for overfill protection of water-endangering flammable or non-flammable liquids. Up to three measuring instruments can be connected; it is used for two-point control and limit detection. When used with Liquiphant with the FEL57 electronic insert, functional safety up to SIL3 in accordance with IEC 61508 is achieved.

Advantages
Nivotester FTL375P is used to connect one, two or three measuring units (single-, dual- or three-channel device)
Ex ia intrinsically safe signal circuit allows the measuring instruments to be used in hazardous areas
Using the online monitoring function, functional safety up to SIL2 is achieved; simple self-test at the push of a button in accordance with WHG/SIL
European-format Racksyst card in accordance with DIN 41494, width 4 HP, height 3 HU
Input channels are electrically isolated from each other and from the power supply and output channels

Application
Switching unit with intrinsically safe signal circuit for connecting Liquiphant or Soliphant.
Ambient temperature: -20...+70°C (-4...+158°F)
International explosion protection certificates, WHG overfill protection, marine approval

 

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

All documents for this model
1 documents · click to expand
TI

Nivotester FTL 375 P Technical Information English

20 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · tuning fork — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was vibrating-fork point level detection and high/low alarms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing fork length and surface finish by density and stickiness.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing fork length and surface finish by density and stickiness, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no calibration needed, with dependable switching, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · tuning fork — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from tuning fork, focusing on vibrating-fork point level detection and high/low alarms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The tuning fork specification must therefore cover choosing fork length and surface finish by density and stickiness.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing fork length and surface finish by density and stickiness, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no calibration needed, with dependable switching, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · tuning fork — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is tuning fork; the focus is vibrating-fork point level detection and high/low alarms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing fork length and surface finish by density and stickiness.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing fork length and surface finish by density and stickiness, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no calibration needed, with dependable switching, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · tuning fork — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on tuning fork and the core task is vibrating-fork point level detection and high/low alarms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So tuning fork cannot be specified generically — it calls for choosing fork length and surface finish by density and stickiness.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing fork length and surface finish by density and stickiness, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no calibration needed, with dependable switching.