Technical Data
ComparePoint Level / Liquids
| Measuring Principle | Vibration Liquids |
| Characteristic / Application | Advanced device for point level detection in hygienic/aseptic applications. Focus Food & Beverage and Life Sciences. Compact sensor version with an optional pipe extension up to 1,5 m (5 ft). Compact hygiene housing. Wide range of certificates. |
| Specialities | Plug and play functionalities One-Button Operation Heartbeat Technology IO-Link Bluetooth® Operation and maintenance Surface finish: mechanical or electro-polished |
| Supply / Communication | 12…30V DC-PNP IO-Link 8/16mA HART |
| Ambient temperature | -40 °C...+85 °C (-40 °F...+185 °F) |
| Process temperature | -40 °C...+150 °C (-40 °F...+302 °F) |
| Process pressure / max. overpressure limit | Vacuum...64 bar (Vacuum...928 psi) |
| Min. density of medium | 0.5 g/cm³ (25.0 lb/ft3) (0.4 g/cm³ (31.2 lb/ft3) optional) |
| Main wetted parts | 316L |
| Process connection | Threads (for weld-in adapter): G3/4A, G1A Flanges: DN25...DN50 (EN1092-1) NPS 2" Cl.150 (ASME B16.5, RF) |
| Process connection hygienic | Tri-Clamp DIN 11851, DIN11864-1 Ingold Flush mount DRD SMS1145 Varivent (Varinline) |
| Sensor length | Compact sensor Short tube/Preferential length 148mm…1500mm (6,00…59") |
| Communication | IO-Link HART Bluetooth® wireless technology |
| Certificates / Approvals | ATEX, IEC Ex, CAN/US, JPN Ex, KC Ex, INMETRO Ex, NEPSI Ex/CCC, UK Ex |
| Safety approvals | Overfill protection WHG |
| Design approvals | Inspection certificate 3.1, EN10204 Conformity to cGMP Declaration of Conformity ASME B31.3 AD2000 CRN approval |
| Hygienic approvals | 3-A EHEDG CoC-ASME BPE EU Food Contact Material (EC) 1935/2004 US Food Contact Material FDA CFR 21 CN Food Contact Material GB 4806 |
| Options | Customized settings Weld-in adapter |
| Components | RN22 RN42 SFP20 |
Liquiphant FTL43 – hygienic point level switch for liquids
Field-proven, particularly compact and ideal for hygienic applications
Advantages
Excellent ease of use thanks to easy commissioning and plug-and-play functionality
Increased process and product safety through configuration integrity - the checksum algorithm (CRC) ensures that safety-related parameters remain unchanged
Increased productivity through traceable and documented on-demand verification (without interrupting the process) and continuous diagnostics using Heartbeat Technology
Documented compliance through certified hygienic design and verified material consistency and traceability
User-friendly operation with guided wizards and extensive digital communication options
Field of application
The Liquiphant FTL43 is a point level switch for liquids and part of the Compact Line family. This product family was developed specifically for hygienic applications and combines a compact design with full performance. The proven vibronic technology works reliably in all pumpable liquids without medium adjustment. The Liquiphant FTL43 is characterized by its ease of use, plug-and-play functionality and extensive digital communication options.
The Liquiphant FTL43 is used for point level detection in process tanks, storage tanks and pipes.
The Liquiphant FTL43 is suitable for a wide range of hygienic applications:
Level detection in narrow skids and various liquid modules
Pump dry-run protection in pipes
Overfill protection in process tanks
Detection of media with different densities
Spare Parts & Accessories 29
29 spare parts · click to collapse
| Order code | Description | |
|---|---|---|
| 52014424 | Sealing gasketfor weld-in adapter G1, adjustable, 316L (52001221) Liquiphant M "GW2" for weld-in adapter G1, adjustable, 316L (52011898) Liquiphant M "GW2" for weld-in adapter G1, adjustable Liquiphant FTL330H/FTL330L, Liquiphant T FTL20H "UPJ | Details |
| 71075662 | Sealing gasketMaterial: silicone VMQ. USP Class VI, FDA. Usage: Process connect. G1 flush mount, Weld-in adapter G1, 316L, adjustable (52001221), Weld-in adapter G1, 316L, 3.1, adjustable (52011898), FTL31/FTL33, FTL80/FTL81, FTL50/FTL50H/FTL51/FTL51H, PMP43, Weld-in adapter Rd52, 316L, adjustable, (52001047), 316L, 3.1, adjustable, (52006909), FTL33, FTL50/FTL50H/FTL51/FTL51H. | Details |
| 52014473 | O-ringfor weld-in adapter G3/4 Liquiphant M "GQ2" | Details |
| 52014472 | O-ringfor weld-in adapter G1 (52001051) Liquiphant M "GW2" Liquiphant T "7", Liquicap M "GWJ", Cerabar T PMP135 "N", Ceraphant T PTP35 "BB" for weld-in andapter G1, 316L 3.1 (52011896) Liquiphant M "GW2", Cerabar T PMP135 "N", Ceraphant T PTP35 "BB" for sliding sleeve Soliphant T | Details |
| 71140668 | O-ringMaterial: EPDM 70. USP Class VI, 3-A. Usage: weld-in adapter G1, 316L, (52001051) flush mount, FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTL43, FTW23, FTW33, PMP23, PMP51, PTP33B, FTL50, FTL50H, FTL51, FTL51H, FTL80, FTL81, PMP43, QMW43, Weld-in adapter G1, 316L, 3.1, (52011896) flush mounted, FMI51, FMI52, FTI51, FTI52, FTL31, FTL33, FTW23, FTW33, PMP23, PMP51, PTP33B, FTL50, FTL50H, FTL51, FTL51H, FTL80, FTL81, PMP43, QMW43, sliding sleeve FTM21. | Details |
| 52024228 | O-ringFit to weld-in adapter DRD-DN50. Flush mount FTL43, FTL50H, FTL51H, PMC51, pressure device. | Details |
| 71655762 | metal TAG holderConsists of: TAG clip M12, key ring D17. Usage: FMR43, FTL43, PMP43. | Details |
| XPRFID- | Spare RFID TAGConsists of: RFID TAG, fixing wire, crimp sleeve. | Enquire |
| XPSPEC- | tagged spare partsAttention: Only 1 piece per position orderable in offer/order because of item category group ZTA1. Consists of: TAG, fixing wire, crimp sleeve. | Enquire |
| 71638253 | M12 90° socket, IP6990 degree angled. Customizable. For hygiene applications. Material grip body: PA. Material union nut: stainless steel. Material seal: EPDM. Usage: FMR43, FTL43, PMP43. | Details |
| 71638191 | M12 straight socket, IP69Customizable. For hygiene applications. Material grip body: PA. Material union nut: stainless steel. Material seal: EPDM. Usage: FMR43, FTL43, PMP43. | Details |
| 52024216 | Cable socketM12x1 plug 5m cable PVC, 316L lock Especially for sanitary applications | Details |
| 52010285 | M12 connector, 90° angled, with 5 m cable适用于M12插头 带5m电缆 PVC材质,铜镀锡/ 镍锁紧螺母 | Details |
| 52001047 | weld socket齐平式安装 过程连接 材质: 316L | Details |
| 52006909 | weld socketFlush mount process connection FTL20H "UPJ", FTL50H/FTL51H "EE2" Material: 316L Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 52001052 | weld socketFlush mount process connection FTL50/FTL50H "GQ2" Material: 316L Seal: Silicone O-ring | Details |
| 52011897 | weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material. Seal: silicone O-ring. FDA, 3-A compliant. additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FTL41, FTL43, FTL50, FTL50H, FTL51B, FTL63, FTL80, QMW43, TMR35. | Details |
| 52001221 | weld socketFlush mount process connection FTL260 "0", FTL20 "7", FTL20H "GEJ", FTL330H/FTL330L "G", FTL50/FTL51, FTL50H/FTL51H "GW2" Liquiphant is adjustable Material: 316L Seal: Silicone O-ring | Details |
| 52011898 | weld socketFlush mount process connection FTL260 "0", FTL20H "GEJ", FTL50/FTL51, FTL50H/FTL51H "GW2" Liquiphant is adjustable Material: 316L Seal: Silicone O-ring Inspection cert. EN10204-3.1 material (316L wetted parts) | Details |
| 71093129 | weld socketFlush mount process connection. Material: 316L. Inspection cert. EN10204-3.1 material Seal: silicone O-ring FDA, 3-A compliant. Additional EPDM O-ring. FDA, EHEDG, 3-A, USP Class VI compliant. Usage: FMI51, FMI52, FTI51, FTI52, FTL31, FTL20H, FTL33, FTL41, FTL43, FTL50, FTL50H, FTL51, FTL51B, FTL51H, FTL63, FTL80, FTL81, FTL260, PMP135, PTP35, PTP33B, PMP23, PMP43, PMP51, FTW23, FTW33, QMW43. | Details |
Configurator / Comparison
Source:Endress+Hauserpublic information from the website
Measuring principle video
Click to play10 documents · click to expand
BA Liquiphant FTL43 Chinese
BA Liquiphant FTL43 Chinese
BA Liquiphant FTL43 English
BA Liquiphant FTL43 English
TI 焊接接头、过程转接头和法兰 Chinese
TI Liquiphant FTL43 IO-Link通信 Chinese
TI Liquiphant FTL43 HART Chinese
TI Weld-in adapter, process adapter and flanges English
TI Liquiphant FTL43 IO-Link English
TI Liquiphant FTL43 HART English
Case Studies
Municipal Wastewater Treatment · tuning fork — Application Case
Site Conditions
This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was vibrating-fork point level detection and high/low alarms.
The Problem
The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing fork length and surface finish by density and stickiness.
What We Did
We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing fork length and surface finish by density and stickiness, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.
Operating Outcome
In service the system performs as intended — no calibration needed, with dependable switching, with routine maintenance falling noticeably.
Food & Beverage · tuning fork — Application Case
Application Context
dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from tuning fork, focusing on vibrating-fork point level detection and high/low alarms.
Process Constraints
frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The tuning fork specification must therefore cover choosing fork length and surface finish by density and stickiness.
Delivery Approach
Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing fork length and surface finish by density and stickiness, together with food-safety and hygienic design per 3-A / EHEDG.
Field Results
Operation shows the benefit clearly — no calibration needed, with dependable switching, with confidence in this measuring point improving markedly.
Chemical & Pharmaceutical · tuning fork — Application Case
Customer Profile
The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is tuning fork; the focus is vibrating-fork point level detection and high/low alarms.
Key Difficulties
Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing fork length and surface finish by density and stickiness.
Implementation
The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing fork length and surface finish by density and stickiness, and on these requirements: Ex certification and GMP traceability of records.
Customer Benefit
In practice this means no calibration needed, with dependable switching, which cut the workload on the site maintenance team.
Power & Energy · tuning fork — Application Case
Project Background
The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on tuning fork and the core task is vibrating-fork point level detection and high/low alarms.
Operating Challenges
The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So tuning fork cannot be specified generically — it calls for choosing fork length and surface finish by density and stickiness.
Solution
The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing fork length and surface finish by density and stickiness, with these requirements in view: compliance with power-industry codes and unit availability targets.
Results
Since start-up the system has run steadily; the practical result is no calibration needed, with dependable switching.