Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FTL85 Liquiphant

FTL85 Liquiphant
Liquiphant FTL85
Liquiphant FTL85 is a coated point level switch for use in hazardous areas with all international certificates. FailSafe overfill prevention in applications with functional safety up to SIL3 with one device. With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials. Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Compare

Point Level / Liquids

Measuring Principle Vibration Liquids
Characteristic / Application Coated point level switch for MIN and MAX safety applications up to SIL3,
Dual Sealing/ Second line of defense,
Modular housing concept
Specialities Outstanding features:
- permanent LIVE signal monitors function safety
- failsafe design and
- high availability of the measuring values
Supply / Communication 2-wire 4...20 mA
Ambient temperature -50°C...+70°C
(-58°F...+160°F)
Process temperature –50°C...+150°C
(–58°F...+300°F)
Process pressure / max. overpressure limit Vacuum...40 bar
(580 psi)
Min. density of medium Density from 0.4 g/cm3
(0.4 SGU)
Main wetted parts With high corrosion-resistant coating made of enamel, ECTFE and various PFA materials
Process connection Flange:
DN25...DN100,
ASME 1"...4",
JIS 10K...20K
Sensor length Extension pipe up to 3 m (9.8 ft)
Communication 2-wire 4...20 mA
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, NEPSI, EAC
Safety approvals Overfill protection WHG
Leakage Detection
SIL3
Options AlloyC Material
PWIS free
Pressure tight feed through
Weather protection
Components Nivotester FTL825, Transmitter

The Liquiphant FTL85 coated vibronic point level switch can be used in hazardous areas, has multiple international approvals, is used for fail-safe overflow protection applications and meets SIL3 functional safety requirements. With corrosion-resistant coatings of enamel, ECTFE and various PFA materials, it measures reliably. The measurement is unaffected by changes in medium properties, fluid turbulence, bubbles, foam, vibration and buildup.

 

Benefits

Suitable for safety systems requiring SIL2/SIL3 functional safety, in accordance with IEC 61508 Ed.2.0 / IEC 61511-1 / ISA 84-1 / DIN EN ISO 13849

Verification test: verification test interval 12 years, one-key test of the entire loop

Permanent self-monitoring/internal redundancy

4-20 mA interface (per NAMUR NE 06/NE 43): easy integration via a two-channel switching unit (safety contacts) output and latching function (Nivotester FailSafe FTL825), or direct integration with a safety PLC

No calibration required: fast and economical device startup

No mechanical moving parts, no maintenance, no wear and a long service life.

Monitors the fork for damage, corrosion, buildup and mechanical blockage

 

Application areas

Limit switch achieves functional safety level SIL3.

Process connection: thread and flange

Temperature: -50... +150 °C (-76... +300 °F)

Pressure: -1... +40 bar (-14.5 ... +580 psi)

Sensor length: extension tube up to 3 m (9.8 ft)

Sensor material: enamel, ECTFE and various PFA materials

International explosion protection approval, WHG overflow protection, SIL

Spare Parts & Accessories 32

32 spare parts · click to collapse
Order codeDescription
52025606plastic coverGasket EPDM Polyester housingDetails
52025790Transparent coverGasket EPDM Polyester housingDetails
52004137O-ringCover seal set Polyester housing F16Details
52004133Adapterfor Polyester housing F16Details
52004134Adapterfor Polyester housing F16Details
52004135Adapterfor Polyester housing F16Details
52002698Aluminum coverO-ring EPDM for Aluminium housing F13, Ex dDetails
52002699Aluminum coverO-ring EPDM for Aluminium housing F17Details
52027693Aluminum coverO-ring 70,0x3,0 EPDM for Aluminium housing F13/F17/F18 not for EEx dDetails
71114754CoverMaterial: 316L. O-ring 70.0x3.0 EPDM. Usage: stainless steel housing F27, FTL50/FTL51/FTL51C, FTL70/FTL71, FTL80/FTL81/FTL85.Details
71185025CoverMaterial: 316L. O-ring 70.0x3.0 FVQM. Usage: stainless steel housing F27, FTL80/FTL81/FTL85, FTM50/FTM51/FTM52.Details
52004277Seal kitconsists of: 10x O-ring 70,0x3,0 EPDMDetails
71114756Seal kitConsists of: 5x O-ring 70.0x3.0 FVQM. Usage: FTL50/FTL51/FTL51C, FTL70/FTL71, FTL80/FTL81/FTL85.Details
52027000Stainless Steel CoverGasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15Details
52027002Window cover with gasketSight glass: glass Gasket 67,5x2,9x1,5 VMQ/PTFE Stainless steel housing F15Details
52028179gasketProfile gasket for cover Stainless steel housing F15Details
52002447cable entryconsists of: adapter M20 > G1/2, 304 gasket NBR blind plug G1/2 Cerabar M, Liquiphant MDetails
52002448cable entryconsists of: adapter M20 > NPT1/2, 304 gasket NBR plug NPT1/2 Cerabar M, Liquiphant MDetails
52004278cable glandconsists of: cable gland M20 O-ring FKM, plug Pg11 PADetails
71185029cable glandConsists of: cable gland M20, metal. O-ring 17.0x2.0 EPDM + PTFE/FDA. Usage: stainless steel housing F15, FTL50/FTL50H/FTL51/FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/FTL85.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: public information from the Endress+Hauser website

Measuring principle video

Click to play
All documents for this model
7 documents · click to expand
BA

BA Liquiphant FailSafe FTL85 Chinese

Rev. 0126 40 pages
Preview
BA

Liquiphant FailSafe FTL80, FTL81, FTL85 Operating Instructions English

Rev. 0213 36 pages
Preview
BA

BA Liquiphant FailSafe FTL85 English

Rev. 0126 44 pages
Preview
TI

技术资料 Liquiphant FailSafe FTL80, FTL81, FTL85 Chinese

Rev. 0213 32 pages
Preview
TI

TI Liquiphant FailSafe FTL85 Chinese

Rev. 0126 28 pages
Preview
TI

Liquiphant FailSafe FTL80, FTL81, FTL85 Technical Information English

Rev. 0213 32 pages
Preview
TI

TI Liquiphant FailSafe FTL85 English

Rev. 0126 32 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · tuning fork — Application Case

Site Conditions

This is a Municipal Wastewater Treatment customer whose plant is at the inlet, biological and outlet stages of a municipal plant. The main task was vibrating-fork point level detection and high/low alarms.

The Problem

The difficulty lies in high solids and corrosive fractions, with large diurnal flow swings; at the same time effluent parameters drift and probes foul with sludge and biofilm. Specification therefore means choosing fork length and surface finish by density and stickiness.

What We Did

We took a level range approach — level solution matched to the actual tank and silo geometry. Delivery was built around choosing fork length and surface finish by density and stickiness, with point-by-point checks on: stable compliance with Grade 1A discharge limits and online data reporting.

Operating Outcome

In service the system performs as intended — no calibration needed, with dependable switching, with routine maintenance falling noticeably.

Food & Beverage

Food & Beverage · tuning fork — Application Case

Application Context

dosing, pasteurising, filling and CIP stages is a typical Food & Beverage duty. The project started from tuning fork, focusing on vibrating-fork point level detection and high/low alarms.

Process Constraints

frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles, and syrups, dairy and beverages that scale easily, under strict hygienic requirements only amplify it. The tuning fork specification must therefore cover choosing fork length and surface finish by density and stickiness.

Delivery Approach

Delivery was handled as the level range — level solution matched to the actual tank and silo geometry. Execution centred on choosing fork length and surface finish by density and stickiness, together with food-safety and hygienic design per 3-A / EHEDG.

Field Results

Operation shows the benefit clearly — no calibration needed, with dependable switching, with confidence in this measuring point improving markedly.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · tuning fork — Application Case

Customer Profile

The typical setting in Chemical & Pharmaceutical is reactors, metering vessels and finished-product tanks. The measuring point is tuning fork; the focus is vibrating-fork point level detection and high/low alarms.

Key Difficulties

Conditions are highly corrosive media with solvents and crystallisation, partly in explosive atmospheres and, on top of that, corrosion plus Ex protection shortens instrument life and makes downtime costly, which a standard configuration cannot handle for long. The design therefore starts with choosing fork length and surface finish by density and stickiness.

Implementation

The scope ran through the level range: level solution matched to the actual tank and silo geometry. Technically it hinges on choosing fork length and surface finish by density and stickiness, and on these requirements: Ex certification and GMP traceability of records.

Customer Benefit

In practice this means no calibration needed, with dependable switching, which cut the workload on the site maintenance team.

Power & Energy

Power & Energy · tuning fork — Application Case

Project Background

The project covers boiler feedwater, turbine condensate and FGD/DeNOx systems. The work centres on tuning fork and the core task is vibrating-fork point level detection and high/low alarms.

Operating Challenges

The medium and duty are characterised by high temperature and pressure with both steam and saline water, and drift under high temperature and pressure, with very costly unplanned outages. So tuning fork cannot be specified generically — it calls for choosing fork length and surface finish by density and stickiness.

Solution

The Ainstru engineering team worked through the level range: level solution matched to the actual tank and silo geometry. The configuration involves choosing fork length and surface finish by density and stickiness, with these requirements in view: compliance with power-industry codes and unit availability targets.

Results

Since start-up the system has run steadily; the practical result is no calibration needed, with dependable switching.