Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

J22 TDLAS Gas Analyzer

J22 TDLAS Gas Analyzer
TDLAS Gas Analyzer J22
The J22 gas analyzer uses patented tunable diode laser absorption spectroscopy (TDLAS) technology to provide accurate measurement of H2O in natural gas. Featuring the reliable diagnostic capabilities of Heartbeat Technology, the J22 analyzer determines the concentration of a gas without coming into physical contact with streams. It allows pipeline operators and suppliers to meet quality specifications, prevent pipeline corrosion, and stop hydrate formation to ensure safety and asset integrity.

The J22 gas analyzer uses TDLAS tunable diode laser absorption spectroscopy technology to precisely determine water vapor (H2O) in natural gas. Equipped with the reliable self-diagnostic functions of Heartbeat Technology, the J22 analyzer directly determines gas concentration without contacting the sample gas. It is specifically tailored for natural gas pipeline operators and natural gas suppliers, helping them ensure gas quality compliance, prevent pipeline corrosion, prevent natural gas hydrate formation and protect life and property.

Benefits
Ensures high availability in natural gas production, transportation, storage and distribution

  • User-friendly interface, intuitive menu display and web server communication

  • Built-in Heartbeat self-diagnostics and self-verification

  • Automatic saving of historical data and spectral logs

  • NIST-traceable calibration with ultra-high accuracy and high repeatability

  • Robust design for easy installation, commissioning and maintenance of the analyzer

  • Supports on-site replacement of parts and modules for minimum downtime

Applications
Determines natural gas quality during production, storage, transportation and distribution

  • Monitoring and control for natural gas pipeline operators, processing plants, compressor stations, gas platforms and transmission/distribution networks

  • Ideal choice for custody transfer measurement, ensuring gas quality compliance

  • Measuring range extendable to 0...6000 ppm (0...284 lb/mmscf) H2O

 

Spare Parts & Accessories 52

52 spare parts · click to collapse
Order codeDescription
70188819Cable, controller to sensor, J seriesCable, controller to sensor, for J series TDLAS analyzerDetails
70188820Cover for optical head enclosureCover, for optical head enclosure for J22 TDLAS analyzersDetails
70188821Cell tube and mirror, 0.8 mCell tube and mirror, 0.8 mDetails
70188822Mirror, flat, for 0.8 meter cellMirror, flat, for 0.8 meter cellDetails
70188825Pressure sensor, digital, for J seriesPressure sensor, digital, for J series TDLAS analyzerDetails
70188826Spectrometer seals, FKM, for J22 TDLASSpectrometer seals, FKM, for J22 TDLAS analyzerDetails
70188827Service tools 01, for J22 TDLAS analyzerService tools 01, for J22 TDLAS analyzersDetails
70188828Cover with glass, aluminum, for J seriesCover with glass, aluminum, for J series TDLAS analyzerDetails
70188829Cover for electronics, aluminumCover for electronics, aluminumDetails
70188831Protective cover for J series analyzerProtective cover for J series analyzerDetails
70188832Display module, for J series TDLASDisplay module, for J series TDLAS analyzerDetails
70188833Module, cartridge, for J series TDLASModule, cartridge, for J series TDLAS analyzerDetails
70188834Connection terminal, for J series TDLASConnection terminal, for J series TDLAS analyzerDetails
70188835T-DAT Memory for J-series TDLASMemory, T-DAT, for J series TDLAS analyzerDetails
70188836Memory, micro SD card, for J seriesMemory, micro SD card, for J series TDLAS analyzerDetails
70188837Power supply, 100 - 230 VAC, J seriesPower supply, 100 - 230 VAC, for J series TDLAS analyzerDetails
70188838Power supply, 24 VDC, for J series TDLASPower supply, 24 VDC, for J series TDLAS analyzerDetails
70188839Module, I/O, configurable, J seriesModule, input/output, configurable, for J series TDLAS analyzerDetails
70188840Relay output module for J series TDLASModule, relay output, for J series TDLAS analyzerDetails
70188841RS485 module, slot 1, for J series TDLASRS485 module, slot 1, for J series TDLASDetails

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

Source: Endress+Hauserpublic information from the website

Diagnostic codes(69 条)→
All documents for this model
4 documents · click to expand
BA

J22 TDLAS气体分析仪《操作手册》 Chinese

Rev. 0624 162 pages
Preview
BA

J22 TDLAS gas analyzer Operating Instructions English

Rev. 0624 162 pages
Preview
TI

J22 TDLAS气体分析仪的《技术资料》 Chinese

Rev. 0625 34 pages
Preview
TI

J22 TDLAS gas analyzer Technical Information English

Rev. 0625 34 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Gas Analysis — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Gas Analysis properly configured on the existing plant, with the aim of continuous analysis of target components in flue or process gas.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Gas Analysis configuration has to involve choosing the analysis principle by range, background gas and conditioning.

Configuration

Supply and installation were organised through the analyser range: selecting as part of a complete water-analysis system. On site this meant choosing the analysis principle by range, background gas and conditioning, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is optimised combustion, cutting both fuel use and emissions, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Gas Analysis — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was continuous analysis of target components in flue or process gas.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means choosing the analysis principle by range, background gas and conditioning.

What We Did

We took a analyser range approach — selecting as part of a complete water-analysis system. Delivery was built around choosing the analysis principle by range, background gas and conditioning, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — optimised combustion, cutting both fuel use and emissions, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Gas Analysis — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Gas Analysis, focusing on continuous analysis of target components in flue or process gas.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Gas Analysis specification must therefore cover choosing the analysis principle by range, background gas and conditioning.

Delivery Approach

Delivery was handled as the analyser range — selecting as part of a complete water-analysis system. Execution centred on choosing the analysis principle by range, background gas and conditioning, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — optimised combustion, cutting both fuel use and emissions, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Gas Analysis — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Gas Analysis; the focus is continuous analysis of target components in flue or process gas.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with choosing the analysis principle by range, background gas and conditioning.

Implementation

The scope ran through the analyser range: selecting as part of a complete water-analysis system. Technically it hinges on choosing the analysis principle by range, background gas and conditioning, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means optimised combustion, cutting both fuel use and emissions, which cut the workload on the site maintenance team.