Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

雷达液位计 NMR81

雷达液位计 NMR81

雷达液位计 NMR81

Configurable Models 20 models
Micropilot NMR81 is used for custody transfer and inventory control applications with NMi- and PTB-approvals and meets the requirements according to OIML R85 and API 3.1B. NMR81 is particularly suited for free space applications up to 70m. The drip-off lens antenna with 80 GHz transmitting frequency produces a sharply focused beam angle of 3° and avoids obstacles even close to tank wall.
Compare

Continuous / Liquids

Measuring Principle Level radar
Characteristic / Application Lens antenna, 80GHz: High precision measurement for for storage tanks up to 30 m (98ft)
Specialities Custody transfer level measurement
Measurement close to tank wall
Supply / Communication 85-264VAC
52-74VAC
19-64VDC
Accuracy up to 0.5 mm
Ambient temperature Standard:
-40°C…60°C
(-40°F...140°F)
For calibration to regulatory
standards:
-25°C…55°C
(-13°F...131°F)
Process temperature -40°C...200°C
(-40°F...392°F)
Process pressure / max. overpressure limit Vacuum.....16 bar abs
Main wetted parts 316L, PTFE
Process connection Flange:
DN50/2"…DN300/12"
Flange w/ Alignment tool:
DN100/4"…DN300/12"
UNI-Flange:
DN150/6"…DN300/12"
UNI-Flange w/ Alignment tool:
DN150/6"…DN300/12"
Max. measurement distance 70 m (230 ft)
For calibration to regulatory standards:
50 m (164 ft)
Communication Outputs:
Fieldbus: Modbus RS485, V1, WM550
HART, BPM and TRL/2 (via GE option)
Analog 4-20mA output (Exi/ Exd)
Relay output (Exd)
Inputs:
Analog 4-20mA input (Exi/ Exd)
2-, 3-, 4-wire RTD input
Discrete input (Exd, passive/active)
Certificates / Approvals ATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex,
INMETRO, NEPSI, UK Ex
Safety approvals Overfill protection WHG
SIL
Design approvals EN 10204-3.1
NACE MR0175, MR0103
AD2000
Metrological approvals and certificates OIML, NMi, PTB
Options Redundant fieldbus
Alu-coated or 316L housing
Weather protection cover
Adjustable mounting seals
Application limits Maximum measuring range is
dependent on the tank form and/
or application
Strong condensate or build-up
formation

Micropilot NMR81 can be used for custody transfer and inventory control measurements and is certified by NMi and PTB, complying with the relevant requirements of R85 and API 3.1B. NMR81 is particularly suitable for measurement in free space with a maximum range of 70 m. It uses an 80 GHz droplet antenna with a small 3° beam angle, which prevents any obstacles close to the tank wall from affecting the measurement.

Advantages
Hardware and software design in accordance with IEC 61508, maximum safety SIL3 (in homogeneous redundant systems)
Maximum measuring accuracy of ±0.5 mm (±0.02"), therefore maximum reliability
Design complies with international metrology regulations, e.g. OIML R85 and API MPMS standards
Local and national certifications, e.g. NMi or PTB certification for custody transfer applications
Simple connection to higher-level DCS systems via open protocols, easy installation and trouble-free operation
80 GHz technology with a highly focused beam angle, unaffected by tank walls and other structures

Application
The 80 GHz droplet antenna is suitable for measurement in free space with a maximum range of 70 m, with a small beam angle, suitable for short nozzle applications close to the tank wall.
Process connection: flange
Temperature: -40...+200°C (-40...+392°F)
Pressure: vacuum...+16 bar (vacuum...+232 psi)
Measuring range: max. 70 m (230 ft)
Measuring accuracy: ±0.5 mm (±0.02")
Operating frequency: 80 GHz
International explosion protection and custody transfer certification, WHG overfill protection, SIL certification

 

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserwebsite public information

Model Name
NMR81-NC1BE1A2X0ACAABA1GUJICX NMR81-NC1BE1A2X0ACAABA1GUJICX
NMR81-BC1BE1A2X0ACAABA1AFJICR NMR81-BC1BE1A2X0ACAABA1AFJICR
NMR81-NC1BE1A2X0ACAABA1GTJICX NMR81-NC1BE1A2X0ACAABA1GTJICX
NMR81-NC1BB1A1X0ACAABA1GTJICX NMR81-NC1BB1A1X0ACAABA1GTJICX
NMR81-NC1BA1A1X0ACAABA1GUJICX NMR81-NC1BA1A1X0ACAABA1GUJICX
NMR81-NC1BC1A2X0ACAABA1GUJICX NMR81-NC1BC1A2X0ACAABA1GUJICX
NMR81-NC1BC1A1X0ACAABA1GUJICX NMR81-NC1BC1A1X0ACAABA1GUJICX
NMR81-NC1BH1A1X0ACAABA1GUJICX NMR81-NC1BH1A1X0ACAABA1GUJICX
NMR81-NC1BC1A1X0ACAABA1GTJICX NMR81-NC1BC1A1X0ACAABA1GTJICX
NMR81-NC1BH1A2X0ACAABA1GUJICX NMR81-NC1BH1A2X0ACAABA1GUJICX
NMR81-NC1BB1A1X0ACAABA1GUJICX NMR81-NC1BB1A1X0ACAABA1GUJICX
NMR81-NC1BH1A1X0ACAABA1GTJICX NMR81-NC1BH1A1X0ACAABA1GTJICX
NMR81-NC1BA1A1X0ACAABA1GTJICX NMR81-NC1BA1A1X0ACAABA1GTJICX
NMR81-NC1BC1A2X0ACAABA1GTJICX NMR81-NC1BC1A2X0ACAABA1GTJICX
NMR81-NC1BA1A2X0ACAABA1GTJICX NMR81-NC1BA1A2X0ACAABA1GTJICX
NMR81-NC1BC1A1X0ACAABA1GSJICX NMR81-NC1BC1A1X0ACAABA1GSJICX
NMR81-NC1BE1A1X0ACAABA1GUJICX NMR81-NC1BE1A1X0ACAABA1GUJICX
NMR81-NC1BH1A2X0ACAABA1GTJICX NMR81-NC1BH1A2X0ACAABA1GTJICX
NMR81-NC1BA1A1X0ACAABA1GSJICX NMR81-NC1BA1A1X0ACAABA1GSJICX
NMR81-NC1BB1A2X0ACAABA1GUJICX NMR81-NC1BB1A2X0ACAABA1GUJICX
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Tank Farm Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Tank Farm.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Tank Farm for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Tank Farm Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Tank Farm.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Tank Farm for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Tank Farm Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Tank Farm.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Tank Farm for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Tank Farm Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Tank Farm.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Tank Farm for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.