Order Code:PMC51-AA21JA2SGCGMJA+AK
Name:Cerabar M PMC51
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 020 | Output | 2 | 4-20mA HART |
| 030 | Display, Operation | 1 | LCD, push button on display/electronics |
| 040 | Housing | J | **F31 Alu, glass window |
| 050 | Electrical Connection | A | Gland M20, IP66/68 NEMA4X/6P |
| 070 | Sensor Range | 2S | 40bar/4MPa/600psi abs, 400mH2O/1334ftH2O/16000inH2O abs overload: 60bar/6MPa/900psi |
| 080 | Reference Accuracy | G | Standard |
| 090 | Calibration; Unit | C | Sensor range; kPa/MPa |
| 110 | Process Connection | GMJ | Thread ISO228 G1/2 hole 11.4mm, 316L |
| 190 | Seal | A | FKM |
| 500 | Additional Operation Language | AK | Chinese simplified |
Configuration Explained
This is a PMC51 pressure transmitter, oil-free ceramic sensor, measures gases and liquids, also usable in hygienic applications, non-hazardous area, 4-20mA HART output, LCD with keys, F31 aluminium housing with glass window, M20 cable gland IP66/68, absolute pressure range 40 bar, overpressure limit 60 bar, standard class accuracy, process connection G1/2, 11.4 mm bore, 316L, FKM seal, Chinese interface, suitable for hygienic and industrial absolute pressure measurement.