Order Code:PMD50-AABACJA37LBKSAJB1B
Name:Deltabar PMD50
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 020 | Output | BA | 2-wire 4-20mA HART |
| 030 | Display; Operation | C | Color display w/o buttons |
| 040 | Housing; Material | J | Dual compartment; Alu, coated |
| 050 | Electrical Connection | A | Gland M20, plastic, IP66/68 NEMA Type 4X/6P |
| 055 | Pressure Type | 3 | Differential |
| 075 | Sensor Range | 7L | 16bar/1.6MPa/240psi |
| 090 | Calibration; Unit | B | Sensor range; mbar/bar |
| 095 | Installation | K | Universal side flange, with vent |
| 110 | Process Connection | SAJ | NPT1/4-18 IEC61518 UNF7/16-20, 316L |
| 170 | Membrane Material | B | AlloyC276 |
| 180 | Fill Fluid | 1 | Silicone oil |
| 200 | Seal | B | PTFE |
Configuration Explained
This is a differential pressure transmitter, with AlloyC276 diaphragm, used to measure differential pressure, level and flow of liquids and gases, for non-hazardous areas, 24V power supply, two-wire with 4-20mA HART output, with colour display, aluminium dual-chamber housing, resistant to shock and vibration, M20 plastic cable gland, IP66/68 protection, range 16 bar, calibrated in mbar/bar, universal flange mounting with vent, NPT1/4 process connection, silicone oil filling, PTFE O-ring, resistant to media corrosion, suitable for differential pressure and level measurement of liquids and gases.