Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

PMD50 differential pressure transmitter

PMD50 differential pressure transmitter
Deltabar PMD50
Configurable Models 20 models
A transmitter with a metal diaphragm for measuring differential pressure, liquid level, and flow rate of liquids and gases
Compare

Continuous / Liquids

Measuring Principle Differential pressure
Characteristic / Application Transmitter with metal membrane
for differential pressure
monitoring in liquids or gases.
Intuitive and clear wizard for
commissioning.
Specialities Zero/Span buttons,
Testclamp,
RFID TAG for easy identification
Supply / Communication Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC
Accuracy Standard:
up to 0.065 %
Platinum:
up to 0.055 %
Long term stability 0.1 % of URL/ year
0.2 % of URL/ 5 years
0.25 % of URL/ 10 years
Ambient temperature -40°C...+85°C
(-40°F...+185°F)
Process temperature -40°C...+110°C
(-40°F...+230°F)
Process connection NPT1/4-18
Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, IECEx, JPN Ex,
INMETRO, NEPSI
Safety approvals SIL
Design approvals EN10204-3.1,
NACE MR0103,
NACE MR0175

Pressure

Measuring Principle Differential pressure
Characteristic Transmitter with metal membrane
for differential pressure
monitoring in liquids or gases.
Intuitive and clear wizard for
commissioning.
Supply voltage Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC
Reference Accuracy Standard:
up to 0.065 %
Platinum:
up to 0.05 %
Long term stability 0.1 % of URL/ year
0.2 % of URL/ 5 years
0.25 % of URL/ 10 years
Process temperature -40°C...+110°C
(-40°F...+230°F)
Ambient temperature -40°C...+85°C
(-40°F...+185°F)
Measuring cell 100 mbar...40 bar
(1.45 psi...580 psi)
Smallest calibratable span 0.3 mbar (0.0043 psi)
Vacuum resistance 25 mbar (0.0375 psi)
Max. Turn down 100:1
Max. overpressure limit 375 bar (5625 psi)
Process connection NPT1/4-18
Material process membrane 316L, AlloyC, Gold
Material gasket PTFE, FKM, EPDM, FFKM
Fill fluid Silicone oil,
Inert oil
Material housing Aluminum, 316L
Communication 4...20 mA HART
Certificates / Approvals ATEX, FM, IECEx, JPN Ex,
INMETRO, NEPSI
Safety approvals SIL
Design approvals EN10204-3.1,
NACE MR0103,
NACE MR0175
Specialities Zero/Span buttons,
Testclamp,
RFID TAG for easy identification

Deltabar PMD50 - differential pressure transmitter
Transmitter with metallic diaphragm for measuring differential pressure, level and flow of liquids and gases
Advantages
Software wizards enable fast and simple commissioning

Device developed in accordance with IEC 61508

Flexible write protection via hardware and/or software wizards

Pre-assembled manifold (pressure and leak tested) for faster installation
Field of application
The Deltabar PMD50 is a differential pressure transmitter with a metallic diaphragm for measuring liquids and gases. It is optimized for standard applications and offers intuitive operating functions.

Pressure measuring range: up to 40 bar (600 psi)

Process temperature up to 400°C (752°F) when using diaphragm seals

Accuracy: up to +/-0.055%

Benefits
Software wizards enable fast and simple commissioning

Device developed in accordance with IEC 61508

Flexible write protection via hardware and/or software wizards

Pre-assembled manifold (pressure and leak tested) for faster installation

Lean selection
Standard product

Reliable, robust, low maintenance

Spare Parts & Accessories 39

39 spare parts · click to collapse
Order codeDescription
71487198Blind plug, M20, 316L, O-ring EPDMConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679714Blind plug M20, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, OFMP50, OFMP51, OFMP57, OFMR51, OFMR54, OFTL41, OFTL51B, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487199Plug: M20, aluminum, EPDM sealing ringConsists of: blind plug, O-ring PTFE coated 17.0x2.0. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679712Blind plug M20, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking o-ring PTFE coated 17,0x2,0. Usage: FMG50, FMP51, FMP52, FMP54, FMP55, FMP56, FMP57, FMR51, FMR52, FMR53, FMR54, FMR57, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL62, FTL64, OFMP51, OFMP57, OFMR51,OFMR54, OFTL51B, PMC71B, PMD50, PMD75B, PMD78B, PMP50, PMP71B.Details
71487201Blind plug, NPT1/2, aluminumConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679718Blind plug NPT1/2, Alu, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71487203Blind plug, NPT1/2, 316LConsists of: blind plug, PTFE coated. Usage: FHX50B, FTL51B, FTL62, FTL63, FTL64, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, NMT81, PMC51B, PMC71B, PMD50, PMD55B, PMD75B, PMD78B, PMP50, PMP51B, PMP71B.Details
71679715Blind plug NPT1/2, 316L, Ex dConsists of: Plug IEC/ATEX Ex d marking, PTFE coated. Usage: FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL64, PMC71B, PMD50, PMD75B, PMD78B, PMP71B, PMP50.Details
71435135Cable gland M20, plastic, suitable for models: FTL41, FTL51B, PMC51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMB70, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMP50, PMP51B, PMP63B, PMP71B.Details
71435136Cable gland M20, nickel-plated brass, suitable for: FMG50, FTL41, FTL51B, PConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL41, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71435137Cable gland M20, 316L, suitable for models: FMG50, FTL51B, PMC51BConsists of: Cable gland, O-ring 17.0 x 2.0 PTFE coated. Usage: FHX50B, FMG50, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64, PMC51B, PMC71B, PMD55B, PMD75B, PMD78B, PMP51B, PMP71B.Details
71474251Enclosure grounding terminal L+PConsists of: spring washer, screw, earth handle, clamp. Usage Liquiphant: Only for digital communication. Usage: FHX50B, FMG50, PMD50, PMD55B, PMD63B, PMD75B, PMD78B, PMC51B, PMC71B, PMP50, PMP51B, PMP63B, PMP71B, FMR60B, FMR62B, FMR63B, FMR66B, FMR67B, FTL51B, FTL62, FTL63, FTL64.Details
71652584Cover Alu, closedSealing ring: HNBR. Usage: PMD50, PMP50.Details
71652584Cover Alu, closedSealing ring: HNBR. Usage: PMD50, PMP50.Details
71652585Cover, aluminium, with sight glassSight glass: Soda lime glass. Usage: PMD50, PMP50.Details
71652587Housing cover, aluminum, flameproofSealing ring: HNBR. Usage: PMD50, PMP50.Details
71652587Housing cover, aluminum, flameproofSealing ring: HNBR. Usage: PMD50, PMP50.Details
71652606Aluminium cover, sight glass, Ex dSealing ring: HNBR. Sight glass: Soda lime glass. Usage: PMD50, PMP50.Details
71652609Cover red Alu, sight glass, Ex dSealing ring: HNBR. Sight glass: Soda lime glass. Usage: PMD50, PMP50.Details
71652610Cover 316L, sight glass, Ex dSealing ring: HNBR. Sight glass: Soda lime glass. Usage: PMD50, PMP50.Details

Configurator / Comparison

ConfigureEnter a product model to configure
CompareEnter the product models to compare — up to three products

   

   

 

 

 

Source:Endress+Hauserpublic information from the website

Measuring principle video

Click to play
2417 models · click to collapse
All documents for this model
4 documents · click to expand
BA

BA Deltabar PMD50 Chinese

Rev. 0426 68 pages
Preview
BA

BA Deltabar PMD50 English

Rev. 0426 76 pages
Preview
TI

TI Deltabar PMD50 Chinese

Rev. 0426 40 pages
Preview
TI

TI Deltabar PMD50 English

Rev. 0426 44 pages
Preview
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Differential Pressure Measurement — Application Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Differential Pressure Measurement properly configured on the existing plant, with the aim of differential pressure for flow and filter monitoring.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Differential Pressure Measurement configuration has to involve checking static pressure limit, overload margin and impulse lines.

Configuration

Supply and installation were organised through the pressure range: pressure solution matched to process pressure and temperature. On site this meant checking static pressure limit, overload margin and impulse lines, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is filters changed on pressure drop, using cartridges to their full life, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Differential Pressure Measurement — Application Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was differential pressure for flow and filter monitoring.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means checking static pressure limit, overload margin and impulse lines.

What We Did

We took a pressure range approach — pressure solution matched to process pressure and temperature. Delivery was built around checking static pressure limit, overload margin and impulse lines, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — filters changed on pressure drop, using cartridges to their full life, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Differential Pressure Measurement — Application Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Differential Pressure Measurement, focusing on differential pressure for flow and filter monitoring.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Differential Pressure Measurement specification must therefore cover checking static pressure limit, overload margin and impulse lines.

Delivery Approach

Delivery was handled as the pressure range — pressure solution matched to process pressure and temperature. Execution centred on checking static pressure limit, overload margin and impulse lines, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — filters changed on pressure drop, using cartridges to their full life, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Differential Pressure Measurement — Application Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Differential Pressure Measurement; the focus is differential pressure for flow and filter monitoring.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with checking static pressure limit, overload margin and impulse lines.

Implementation

The scope ran through the pressure range: pressure solution matched to process pressure and temperature. Technically it hinges on checking static pressure limit, overload margin and impulse lines, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means filters changed on pressure drop, using cartridges to their full life, which cut the workload on the site maintenance team.