Order Code:PMD50-AABACJH37HCNSAXB7R
Name:Deltabar PMD50
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | AA | Non-hazardous area |
| 020 | Output | BA | 2-wire 4-20mA HART |
| 030 | Display; Operation | C | Color display w/o buttons |
| 040 | Housing; Material | J | Dual compartment; Alu, coated |
| 050 | Electrical Connection | H | Thread NPT1/2, IP66/68 NEMA Type 4X/6P |
| 055 | Pressure Type | 3 | Differential |
| 075 | Sensor Range | 7H | 3bar/300kPa/45psi |
| 090 | Calibration; Unit | C | Sensor range; kPa/MPa |
| 095 | Installation | N | Bottom process connection, high pressure side left, with side vent |
| 110 | Process Connection | SAX | NPT1/4-18 IEC61518 UNF7/16-20, Superduplex |
| 170 | Membrane Material | B | AlloyC276 |
| 180 | Fill Fluid | 7 | Inert oil |
| 200 | Seal | R | FFKM |
Configuration Explained
This is a differential pressure transmitter, with AlloyC276 diaphragm, measures differential pressure, level and flow of liquids and gases, for use in non-hazardous areas, 24V supply, two-wire with 4-20mA HART output, with colour display, aluminium dual-chamber housing, resistant to shock and vibration, NPT1/2 thread, IP66/68 protection, range 3 bar, calibrated in kPa/MPa, bottom process connection, high pressure side on the left with side vent, process connection material duplex steel, inert oil filling, FFKM O-ring, suitable for differential pressure measurement of liquid and gaseous media.