Order Code:TMT82-B6A2GB3A1A1A2+E1
Name:iTEMP TMT82, Transmitter HART
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | B6 | ATEX II2G Ex d T6, II2D Ex tb IIIC |
| 020 | Communication; Output Signal | A | HART; 1x 4-20mA |
| 030 | Electrical Connection | 2 | Screw terminals, housing form B, DIN EN 50446 |
| 040 | Field Housing | G | TA30H, Alu, 2x NPT1/2, glass display window (w/o display unit), explosion-proof enclosure |
| 050 | Configuration Universal Input | B3 | Ch1: RTD 3-wire, Ch2: RTD 3-wire |
| 060 | Sensor Type Input 1 | A1 | Pt100, IEC60751 (a=0.00385), -200...+850oC, min. span 10K |
| 070 | Sensor Type Input 2 | A1 | Pt100, IEC60751 (a=0.00385) |
| 080 | Input; Interconnection | A2 | PV=CH1; SV=CH2 |
| 530 | Display; Operation | E1 | Measured value display; DIP-switch, pluggable (TID10) |
Configuration Explained
This is a TMT82 dual-channel temperature transmitter, HART protocol, with ATEX flameproof approval, dual gas and dust explosion protection, can be installed on site in hazardous areas, 1 x 4-20mA HART output, the second path uses the HART SV variable, one device monitors two points at once, saves one transmitter and cabinet space, screw terminal wiring, TA30H explosion-proof housing with 2 x ½ NPT cable entries and glass display window, both channels with Pt100 three-wire input, covers -200 to +850 °C, suitable for monitoring the temperature difference at reactor inlet and outlet.