Order Code:TMT82-E8N0/190
Corresponding ext. order code:TMT82-NAA1AB1A1AAA1
Name:iTEMP TMT82, Transmitter HART
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | NA | NEPSI Ex ia IIC T6 Ga |
| 020 | Communication; Output Signal | A | HART; 1x 4-20mA |
| 030 | Electrical Connection | 1 | Push-in terminals, housing form B, DIN EN 50446 |
| 040 | Field Housing | A | W/o, mounting set DIN terminal head |
| 050 | Configuration Universal Input | B1 | Ch1: RTD 3-wire, Ch2: inactive |
| 060 | Sensor Type Input 1 | A1 | Pt100, IEC60751 (a=0.00385), -200...+850oC, min. span 10K |
| 070 | Sensor Type Input 2 | AA | Inactive |
| 080 | Input; Interconnection | A1 | PV=CH1; CH2 inactive |
Configuration Explained
This is a TMT82 temperature transmitter, HART protocol, with NEPSI intrinsically safe approval, can be installed in hazardous areas, 1 x 4-20mA HART output, tool-free spring terminal wiring, Form B transmitter head design, DIN standard kit installed in the junction box, without field housing, single channel with Pt100 three-wire input, covers -200 to +850 °C, minimum span 10 K, resolves small temperature differences, suitable for transmitter head installation in intrinsically safe chemical loops.