Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

TMT82-NAA2EB1A1AAA1+E1LA

TMT82-NAA2EB1A1AAA1+E1LA
Product family: iTEMP TMT82, Transmitter HART
Temperature transmitter
Endress+Hauser TMT82-NAA2EB1A1AAA1+E1LA
iTEMP TMT82, Transmitter HART;Approval NEPSI Ex ia IIC T6 Ga;Communication/Output Signal HART; 1x 4-20mA;Electrical Connection Screw terminals, housing form B, DIN EN 50446;Field Housing TA30H, Alu, 2

Order Code:TMT82-NAA2EB1A1AAA1+E1LA

Name:iTEMP TMT82, Transmitter HART

Configuration

CodeNameOrderSpecification
010ApprovalNANEPSI Ex ia IIC T6 Ga
020Communication; Output SignalAHART; 1x 4-20mA
030Electrical Connection2Screw terminals, housing form B, DIN EN 50446
040Field HousingETA30H, Alu, 2x M20x1.5, glass display window (w/o display unit), explosion-proof enclosure
050Configuration Universal InputB1Ch1: RTD 3-wire, Ch2: inactive
060Sensor Type Input 1A1Pt100, IEC60751 (a=0.00385), -200...+850oC, min. span 10K
070Sensor Type Input 2AAInactive
080Input; InterconnectionA1PV=CH1; CH2 inactive
530Display; OperationE1Measured value display; DIP-switch, pluggable (TID10)
590Additional ApprovalLASIL

Configuration Explained

This is a TMT82 temperature transmitter, HART protocol, with NEPSI intrinsically safe approval, can be installed in hazardous areas, 1 x 4-20mA HART output, screw terminal wiring, TA30H explosion-proof cast aluminium housing, 2 M20x1.5 cable entries, glass display window with plug-in display module and DIP switch, convenient on-site reading, for use in intrinsically safe loops with safety barrier, Pt100 three-wire input, covers -200 to +850 °C, with SIL declaration of conformity, suitable for temperature measurement in intrinsically safe chemical loops.

191 models · click to collapse