Order Code:TMT82-NDA2EB1A1AAA1+E1LA
Name:iTEMP TMT82, Transmitter HART
Configuration
| Code | Name | Order | Specification |
|---|---|---|---|
| 010 | Approval | ND | NEPSI Ex d IIC T6 Gb, II2D Ex tb IIIC Db |
| 020 | Communication; Output Signal | A | HART; 1x 4-20mA |
| 030 | Electrical Connection | 2 | Screw terminals, housing form B, DIN EN 50446 |
| 040 | Field Housing | E | TA30H, Alu, 2x M20x1.5, glass display window (w/o display unit), explosion-proof enclosure |
| 050 | Configuration Universal Input | B1 | Ch1: RTD 3-wire, Ch2: inactive |
| 060 | Sensor Type Input 1 | A1 | Pt100, IEC60751 (a=0.00385), -200...+850oC, min. span 10K |
| 070 | Sensor Type Input 2 | AA | Inactive |
| 080 | Input; Interconnection | A1 | PV=CH1; CH2 inactive |
| 530 | Display; Operation | E1 | Measured value display; DIP-switch, pluggable (TID10) |
| 590 | Additional Approval | LA | SIL |
Configuration Explained
This is a TMT82 temperature transmitter, HART protocol, with NEPSI flameproof approval, dual gas and dust explosion protection, can be used directly on site in hazardous areas, 24 V supply, 1 x 4-20mA HART output, screw terminal wiring, TA30H explosion-proof aluminium housing with 2 x M20x1.5 cable entries, with glass window and plug-in display module, DIP switch for local setting, Pt100 three-wire input, covers -200 to +850 °C, plus SIL declaration of conformity, suitable for safety interlock measuring points in petrochemical plants.