Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

31230.01

31230.01
Product family: Orbisphere 312xx Hydrogen Sensors
Orbisphere Hydrogen (H₂) EC Sensor in stainless steel with EPDM O-ring (100 bar)
HACH 31230.01
Allows you to monitor hydrogen in the power production process.

产品概述

Allows you to monitor hydrogen in the power production process.

The patented polarographic sensor design is a proven performer wherever knowledge of H2 content is critical. From corrosion monitoring in power generators to chemical manufacturing, this sensor provides fast, accurate hydrogen measurements, in gaseous or liquid samples.

A wide range of temperature and pressure ranges is made possible by the exclusive valve seat sealing, whereby the sensor cathode is mechanically tensioned against a ceramic valve seat to ensure the integrity of the seal. This design enables a vanishingly small residual signal, for improved accuracy.

All these hydrogen sensors use the deep-draw membrane mounting method for a uniformly thin layer of electrolyte for faster response and superior stability. Coupled with a screw-on protection cap, the sensor provides in-service intervals of up to a year.

主要特点

  • Guard Ring Electrode Design:An auxiliary guard ring electrode surrounds the working electrode to shield against the influence of other gases and improve stability.
  • Rugged Construction:Use for harsh chemicals, hot CIP and high pressure situations.
  • Flexibility:Installs in-line for process control, or in flow chamber for spot measurement. Cable detaches at sensor end for installation and maintenance flexibility.

技术参数

参数名称说明
AccuracyThe greater of ±1% of reading, or ±0.03 ppb, or ±1 Pa (Membrane 2956A)
Accuracy 2The greater of ±1% of reading, or ±0.09 ppb, or ±6 Pa (Membrane 2952A)
Accuracy 3The greater of ±1% of reading, or ±1 ppb, or ±50 Pa (Membrane 2995A)
Accuracy 4The greater of ±1% of reading, or ±10 ppb, or ±1 kPa (Membrane 29015A)
Ambient Temperature-5 - 100 °C (23 - 212 °F)
ApplicationCorrosion rate
CertificationsIP68 / NEMA4
Flow RateTypical Flow Rate Membrane 2956A: 50 - 220 mL/min Membrane 2952A: 40 - 200 mL/min Membrane 2995A: 20 - 70 mL/min Membrane 29015A: 20 - 40 mL/min
Protection ClassIP68 / NEMA4
Radiation Resistance LevelMembrane 2956A: 2x104 rad Membrane 2952A: 108 rad Membrane 2995A: 108 rad Membrane 29015A: N/A
RangeRange at 25 °C Membrane 2956A: 0 - 75 ppb or 0 Pa - 5 kPa Membrane 2952A: 0 - 300 ppb or 0 Pa - 20 kPa Membrane 2995A: 0 - 3200 ppb or 0 Pa - 200 kPa Membrane 29015A: 0 ppb - 32 ppm or 0 - 2000 kPa
Sample Pressure0 - 100 bar
Temperature RangeAccurate from -5 - 50 °C (23 - 122 °F) Resistant - temperature from -5 - 100 °C (23 - 212 °F)
Warranty6 months
Weight140 - 700 g, depending on the construction material
What's included?Sensor only. Controller, sensor cable, flow-chamber or process connection must be ordered separately.

同系列其他配置

型号
31292HPOrbisphere Hydrogen (H₂) TC Sensor with carbon dioxide purge, protecti
31292TCOrbisphere Hydrogen (H₂) TC Sensor with carbon dioxide purge, protecti
31290TCOrbisphere Hydrogen (H₂) TC Sensor with nitrogen purge, protection cap
31290HPOrbisphere High Pressure Hydrogen (H₂) TC sensor with nitrogen purge,

资料下载

5 models · click to collapse