Product family:
SP510 Hardness Monitor
SP510 Hardness Analyzer (1 mg/L trip point)
Maximize your softener cycle time and minimize your regeneration cost.
产品概述
Maximize your softener cycle time and minimize your regeneration cost.
Immediately signal hardness breakthrough to activate regeneration. Makes your water softening system more efficient and less costly. Reliable, simple and accurate- with automated calibration. Continuous monitoring in "real time".
主要特点
- Continuous hardness detection:The SP510 monitor detects hardness breakthrough when the capacity of a water softener is exhausted, immediately signaling the need for regeneration. Alarm points are 0.3, 1, 2, 5, 10, 20, 50, and 100 ppm (expressed as mg/L of CaCO3) and are selected by choosing the appropriate model. Easy to read LED indicators show a simple “HARD” or “SOFT” sample status. You can also use SP510’s built-in alarm relay to actuate an external annunciator.
- Low maintenance requirements:The SP510 samples water every two minutes, operating automatically for up to 60 days. It is virtually maintenancefree, requiring only about 15 minutes every two months to replenish and standardise the reagents. Replace tubing in the pump system every six months.
- Convenient, trouble-free operation:The SP510 monitor makes your water softening system more eBcient and less costly. It eliminates the guesswork so your softener is regenerated only when needed. Regeneration based on calculation or set times can be replaced with continuous monitoring and automatic control, lowering reagent consumption.
- Rugged, lightweight, and self-contained:The SP510 case is made of ABS plastic which is lightweight, corrosion-resistant, and shatterproof. This sealed case is IP62-rated and has a hinged door for easy access to internal components.
技术参数
| 参数名称 | 说明 |
|---|---|
| Accuracy | ±25% of set point value |
| Alarm | 2 consecutive cycles above set point activate alarm. 1 cycle below set point cancels alarm. Alarm type: LED indicators, Hard or Soft |
| Alarm points | 1 mg/L of CaCO₃ trip point |
| Certifications | NRTL certified to UL and CSA standards, and CE approved |
| Cycle Time | 2 average |
| Detector | Silicon photo detector |
| Dimensions (H x W x D) | 178 mm mm x 419 mm mm x 318 mm |
| Drain | ½ in. ID flexible hose |
| Enclosure Rating | IP62 |
| Fitting Type | Inlet: ¼-in. OD tube quick-disconnect fitting Outlet: ½-in. ID flexible hose |
| Light Source | LED with peak wavelength of 610 nm |
| Maintenance Interval | Standardize and replenish reagents every 2 months using EDTA or high-level sample Replace pump tubes every 6 months |
| Material Enclosures | ABS plastic, large plastic windows to view alarm and reagents level |
| Measurement Method | Colorimetric, LED with peak wavelength of 610 nm |
| Mounting | Wall, Table or Panel Mount |
| Operating Humidity | 5 - 95%, non-condensing |
| Operating Temperature Range | 5 - 40 °C |
| Optical Path Length | 8.89 mm |
| Outputs | 1 SPDT relay |
| Power Requirements (Hz) | 50/60 Hz |
| Power Requirements (Voltage) | 115/230 VAC, 70 VA, 50/60 Hz, 1.25 A Fuse |
| Range | Hardness levels: 0.3, 1, 2, 5, 10, 20, 50, 100 ppm (expressed as mg/L CaCO3) |
| Reagent Consumption | 500 mL each indicator and buffer every two months |
| Repeatability | ±10% of set point value in 0.3 - 2 mg/L ranges; ± 4% of set point value in 5 - 100 mg/L ranges |
| Sample Flow Rate | 50 - 500 mL/min |
| Sample Inlet Connection | ¼ in. OD tube quick-disconnect fitting |
| Sample Pressure | 0.07 - 0.34 bar (0.10 bar is optimum) Sample conditioning: 0.10 - 5.17 bar |
| Storage Conditions | -40 - 60 °C (-40 - 140 °F) |
| Warranty | 12 months |
| Weight | 11.3 kg (25 lbs) |
| What's included? | SP510 Hardness Monitor, two month's supply of reagents, an installation kit, a maintenance kit, Hach user manual. |
同系列其他配置
| 型号 | |
|---|---|
| 5410003 | SP510 Hardness Analyzer with Reagents (0.3 mg/L trip point) |
| 5410002 | SP510 Hardness Analyzer (2 mg/L trip point) |
| 5410005 | SP510 Hardness Analyzer (5 mg/L trip point) |
| 5410010 | SP510 Hardness Analyzer (10 mg/L trip point) |
| 5410020 | SP510 Hardness Analyzer (20 mg/L trip point) |
| 5410099 | SP510 Hardness Analyzer (100 mg/L trip point) |
| 5410050 | SP510 Hardness Analyzer (50 mg/L trip point) |
资料下载
- Complete Water Analysis for the UPSTREAM OIL & GAS INDUSTRY
- Introduction to Hach Services
- Care Advantage Flyer : Complete service solution for all your instruments
- Care Advantage Brochure : Complete service solution for all your instruments
- Complete Water Analysis Solutions for Power and Steam Generation
- Complete Water Analysis Solutions for Power and Steam Generation
- Soluciones completas de análisis de agua para Generación de energía y vapor
- Solutions complètes d’analyse de l’eau pour La production de vapeur et d’électricité
Related Products
HACHSC1000 relay module for DIN-rail mounting, 4 Relays, max. 240V
View →
HACHNP6000sc Phosphate Analyzers
View →
A
HACHStainless Steel Chain Mount Kit
View →
A
HACHMercury Thermometer, Celsius, -10 to 200°C
View →
A
HACHMercury Thermometer, Fahrenheit, -30 to 120°F
View →
A
HACHAccu4 Spare Chamber with Plumbing, High Pressure
View →
HACHDETECTR,HI GN,10' CABLE
View →
A
HACHCOVER-SERVICE REPLACEMENT
View →