5410002

5410002
Product family: SP510 Hardness Monitor
SP510 Hardness Analyzer (2 mg/L trip point)
HACH 5410002
Maximize your softener cycle time and minimize your regeneration cost.

产品概述

Maximize your softener cycle time and minimize your regeneration cost.

Immediately signal hardness breakthrough to activate regeneration. Makes your water softening system more efficient and less costly. Reliable, simple and accurate- with automated calibration. Continuous monitoring in "real time".

主要特点

  • Continuous Hardness Detection:The Hach SP 510 Hardness Monitor continuously monitors water systems to provide an alarm when total hardness exceeds a pre-set limit (eight alarms are available). By performing an analysis every two minutes, the SP 510 monitor can establish an automatic or semi-automatic system for water softener regeneration in a variety of commercial or industrial applications.
  • Simple to Read and Use:The SP 510 monitor detects hardness breakthrough when the capacity of a water softener is exhausted, immediately signaling the need for regeneration. Alarm points are 0.3, 1, 2, 5, 10, 20, 50, and 100 ppm (expressed as mg/L of CaCO3) and are selected by using the appropriate model. LED indicators show a simple HARD or SOFT sample status. Use the monitor's built-in alarm relay to actuate an external annunciator.
  • Rugged, lightweight, and self-contained:The case of the SP 510 monitor is made of ABS plastic which is lightweight, corrosion-resistant, and shatterproof. This sealed case is IP62-rated and has a hinged door that for easy access to internal components. All electronic circuits are isolated from the hydraulics compartment. A large window allows inspection of both LED indicators and reagent supplies at a glance. Wall-mounting is easy with built-in brackets. The instrument is rated for 115/220 Vac, 50/60 Hz operation, with a switch for voltage selection.
  • Making Water Softening Systems Cost-efficient:The traditional method of determining softener regeneration cycles is based on calculation of the water volume that can pass through a softener before its capacity is exhausted. Many variables (temperature, flow rate, and condition of the exchange resin) can affect the accuracy of these calculations. A substantial safety margin is also generally included, which can result in waste of time and brine used for regeneration. The Hach SP 510 monitor can eliminate this guesswork. The softener is regenerated only when needed, based on accurate chemical analysis rather than estimated volume.
  • Low Maintenance Requirements:The SP 510 monitor is designed for continuous, unattended use. It is virtually maintenance-free, requiring only about 15 minutes every two months to replenish and standardize the reagents. Tubing in the pump system should be replaced at six-month intervals. Spare pump tubing is supplied with the monitor.
  • Reliable, simple, and accurate-with automated calibration:

技术参数

参数名称说明
Accuracy±25% of set point value
Alarm2 consectutive cycles above set point activate alarm. 1 cycle below set point cancels alarm.
Alarm points2 mg/L of CaCO₃ trip point
CertificationsNRTL certified to UL and CSA standards, and CE approved
Cycle Time2 average
DetectorSilicon photo detector
Dimensions (H x W x D)178 mm mm x 419 mm mm x 318 mm
Drain½ in. ID flexible hose
Enclosure RatingIP62
Fitting TypeInlet: ¼-in. OD tube quick-disconnect fitting Outlet: ½-in. ID flexible hose
Maintenance IntervalStandardise and replenish reagents every 2 months using EDTA or high-level sample Replace pump tubes every 6 months
Material EnclosuresABS plastic, large plastic windows to view alarm and reagents level
Measurement MethodColorimetric, LED with peak wavelength of 610 nm
MountingWall, Table or Panel Mount
Operating Humidity5 - 95%, non-condensing
Operating Temperature Range5 - 40 °C
Optical Path Length8.89 mm
Outputs1 SPDT relay
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)115/230 VAC, 70 VA, 50/60 Hz, 1.25 A Fuse
RangeHardness levels: 0.3, 1, 2, 5, 10, 20, 50, 100 ppm (expressed as mg/L CaCO3)
Reagent Consumption500 mL each indicator and buffer every two months
Reagent Requirementseach of indicator and buffer. Replenish every two months for continuous operation.
Repeatability± 10 % of set point value in 0.3 - 2 mg/L ranges ± 4 % of set point value in 5 - 100 mg/L ranges
Sample Flow Rate50 - 500 mL/min
Sample Inlet Connection¼ in. OD tube quick-disconnect fitting
Sample Pressure0.07 - 0.34 bar (0.10 bar is optimum) Sample conditioning: 0.10 - 5.17 bar
Storage Conditions-40 - 60 °C (-40 - 140 °F)
Warranty12 months
Weight11.3 kg (25 lbs)
What's included?SP510 Hardness Monitor, two month's supply of reagents, an installation kit, a maintenance kit, Hach user manual.

同系列其他配置

型号
5410003SP510 Hardness Analyzer with Reagents (0.3 mg/L trip point)
5410005SP510 Hardness Analyzer (5 mg/L trip point)
5410010SP510 Hardness Analyzer (10 mg/L trip point)
5410020SP510 Hardness Analyzer (20 mg/L trip point)
5410099SP510 Hardness Analyzer (100 mg/L trip point)
5410050SP510 Hardness Analyzer (50 mg/L trip point)
5410001SP510 Hardness Analyzer (1 mg/L trip point)