ORP Mini Controller (4-20 mA Analog Output)
HANNA Instruments BL-932700-1
BL-932700 is an ORP mini controller that has been designed for easy, affordable installation in tight spaces, ideal for simple yet effective process control. As a result of its compact size, BL-932700

Overview

BL-932700 is an ORP mini controller that has been designed for easy, affordable installation in tight spaces, ideal for simple yet effective process control. As a result of its compact size, BL-932700 can be installed right next to tanks or vats. An included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.

Large Clear LCD Fire Retardant Casing BNC Connection Adjustable Dosing Relay The BL-932700 features a dosing relay which may be configured to dose above or below a user programmable mV setpoint. Selectable Overdose Protection The mini controller may be programmed to deactivate a valve, pump, or connected device if its activation continues over a selected time; adjustable from 5 to 30 minutes. Selectable Control Override With the flick of a switch, normal “Auto” operation may be overridden turning your connected device “Off” from operation or always “On.” Analogue Output Communication The BL-932700 features a 4 - 20 mA analogue output for connection to a data logger, chart recorder, or other device.

External Disabling Feature A normally open contact may connect to a level controller or flow monitor. This safety feature may be used to prevent continuous dosing in the event of specific or undesired system conditions. Matching Pin Connection An included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.

Specifications

ParameterValue
SKUBL-932700-1
Range±1000 mV
Resolution1 mV
Accuracy±5 mV
Calibrationmanual, with CAL trimmer
Dosing Relay1, max 2A (fuse protected), 250 Vac, 30 Vdc
Dosing Selectionreducing or oxidizing contact open = reducing dosage, activated when reading exceeds setpoint value contact closed = oxidizing dosage; activated when reading falls below setpoint value
Setpointadjustable from -1000 to 1000 mV
Overtimeadjustable, typically from 5 to approx. 30 minutes
Recorder Output4-20 mA, accuracy ±0.20 mA, 500 Ohm max load
Input Impedance10 2 Ohm
Power Supply115/230VAC; 50/60Hz
Dimensions83 x 53 x 99 mm (3.3 x 2.1 x 3.9")
Weight300g