Overview
Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to activate a solenoid that switches from one DI (deionised) tank to another or to open a valve that will allow lower TDS water to flow into a tank being monitored in order to lower its TDS.
The BL-983321 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation. *The BL-983321 uses a 0.5 conversion factor in which 1.00 μS/cm = 0.50 ppm. Adjustable Dry Contact Dosing Relay The BL-983321 features a dosing relay that is activated when the reading is above a user programmable set point.
Programmable Overdose Protection For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled. Relay Control Override With the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.
Multicolour LED Indicator Multicolour LED indicator allows an operator to quickly check the status of the controller. Green = Meter in measurement mode and reading is below the set point Orange/Yellow = Reading is above the set point and the relay is activated Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded Fuse Protected Dosing Contacts The relay dosing contact is rated for up to a 2A load and is fuse protected. Labelled Termination Connections Quick-connect terminal blocks are clearly labelled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.
1/2" NPT Male Threaded Amperometric Probe for Mounting In-line* The BL-983321 mini controller uses the HI-7634-00 conductivity probe that is available with different cable lengths. *HI-7634-00 is not included and must be ordered separately. Order Information: The BL 983321 is supplied with mounting brackets, transparent cover, and instructions.
Specifications
| Parameter | Value |
|---|---|
| SKU | BL-983321-0 |
| Range | 0 to 19.99 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±2% F.S. |
| TDS Conversion Factor | 0.5 |
| Probe | HI 7634-00 (not included) |
| Temperature Compensation | Automatic, 5 to 50°C (41 to 122°F) with ß = 2%/°C |
| Calibration | manual, with CAL trimmer |
| Dosing Relay | 1, max 2A (fuse protected), 250 Vac, 30 Vdc contact closed when reading exceeds setpoint value |
| Setpoint | adjustable from 0 to 19.99 ppm |
| Overtime | adjustable, typically from 5 to approx. 30 minutes |
| Power Supply | 12 VDC adaptor included |
| Dimensions | 83 x 53 x 99 mm (3.3 x 2.1 x 3.9") |
| Weight | 200g |
Manuals and documentation
Related Products
HANNA InstrumentsEPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA InstrumentsHardness, High Range Test Kit
HANNA InstrumentsAlkaline battery size AAA
Large pump head assembly
HANNA InstrumentsRugged Case for Waterproof Meters with Moulded Insert
HANNA InstrumentsAuger for Ground Penetration
HANNA InstrumentsChromium VI High Range Handheld Colorimeter - Checker HC
HANNA Instruments