Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

BL100-20

BL100-20
Pool Controller with Flow Cell Mounting Kit
The BL100-20 is a pool controller with a flow cell mounting kit, supplied with the BL100 controller and HI10053 amplified pH/temperature probe.

Overview

The BL100-20 is a pool controller with a flow cell mounting kit, supplied with the BL100 controller and HI10053 amplified pH/temperature probe. The probe incorporates both pH and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector; the built-in amplifier helps reduce electrical noise from recirculation pumps. The pH sensor is designed to have a 0 mV value at pH 4, so a cracked glass short will produce an alarm state and disable the pump from dosing.

Specifications

ParameterValue
SKUBL100-20
Calibrationuser calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH); Process calibration: single point, adjustable (± 0.50 pH around measured pH)
Process Instrumentation Range-5.0 to 105°C (23.0 to 221.0°F)
Temperature Resolution0.1°C (0.1°F)
Accuracy (@25°C/77°F)±0.5°C (±0.9°F)
Temperature Compensationautomatic
Dosing Control TypeOn/Off control using adjustable set point (6.00 to 8.00 pH) with adjustable hysteresis (0.10 to 1.00 pH); Proportional control using adjustable set point (6.00 - 8.00 pH) with adjustable proportional band (0.10 to 2.00 pH); high or low mode operation
Dosing Control Activationhigh set point dosing is activated when reading is higher than set point (dose acid); low set point dosing is activated when reading is lower than set point (dose base)
Delay Start for Dosingstartup delay timer at power-on (0 to 600 sec.)
Maximum Dosing Timeoverfeed protection using overtime safety timer (1 to 180 min. or Off)
Pump Flow Controlselectable flow rate (0.5 to 3.5 L / hour; 0.13 to 0.92 G/hour); manual control for pump priming
Additional Alarmshigh and low with enable / disable option; triggered after 5 sec. if controller records a set of consecutive readings over / under threshold values; level with enable / disable option; overtime protection (1 to 180 min. or off); intuitive alarm system using red, light green, and green color-coded backlight
Alarm Relay Output (1)SPDT 2.5A / 230 VAC
External Event Inputinput for level controller or flow switch to disable dosing pump in the event of no chemical when using a level controller or no flow when using a flow switch - galvanically isolated
Probe Input (1)HI10053 digital pH/temperature probe with quick connect DIN connector - galvanically isolated
Power Supply100-240 VAC, 50/60 Hz
Power Consumption15 VA
Environment0-50°C (32-122°F), max. 95% RH non-condensing
Dimensions90 x 142 x 80 mm (3.5 x 5.6 x 1.8")
Weight910 g (32 oz.)
Casingwall-mounted, built-in pump, IP65 protection