Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

BL101-00

BL101-00
ORP/Temperature Process Controller
The BL101-00 is a wall-mounted, built-in pump ORP/temperature process controller that uses the HI20083 platinum tip ORP/temperature probe connected via a single waterproof Quick Connect DIN connector.…

Overview

The BL101-00 is a wall-mounted, built-in pump ORP/temperature process controller that uses the HI20083 platinum tip ORP/temperature probe connected via a single waterproof Quick Connect DIN connector. It supports on/off and proportional dosing control with adjustable set point, hysteresis/proportional band, startup delay timer, and overtime overfeed protection. The alarm system uses red, light green, and green color-coded backlight and includes an SPDT alarm relay output.

Specifications

ParameterValue
SKUBL101-00
Calibrationprocess calibration: single point, adjustable (± 50 mV around measured ORP value)
Process Instrumentation Range-5.0 to 105°C (23.0 to 221.0°F)
Temperature Resolution0.1°C (0.1°F)
Accuracy (@25°C/77°F)±0.5°C (±0.9°F)
Dosing Control TypeOn/Off control using adjustable set point (200 to 900 mV) with adjustable hysteresis (10 to 100 mV); proportional control using adjustable set point (200 to 900 mV) with adjustable proportional band (10 to 200 mV); high or low mode operation
Dosing Control Activationhigh set point dosing is activated when reading is higher than set point; low set point dosing is activated when reading is lower than set point (dose oxidizer)
Delay Start for Dosingstartup delay timer at power-on (0 to 600 sec.)
Maximum Dosing Timeoverfeed protection using overtime safety timer (1 to 180 min. or Off)
Pump Flow Controlselectable flow rate (0.5 to 3.5 L / hour; 0.13 to 0.92 G/hour); manual control for pump priming
Alarm Relay Output (1)SPDT 2.5A / 230 VAC
External Event Inputinput for level controller or flow switch to disable dosing pump in the event of no chemical when using a level controller or no flow when using a flow switch - galvanically isolated
Probe Input (1)HI20083 Platinum tip ORP/Temperature probe with quick connect DIN connector - galvanically isolated
Power Supply100-240 VAC, 50/60 Hz
Power Consumption15 VA
Environment0-50°C (32-122°F), max. 95% RH non-condensing
Dimensions90 x 142 x 80 mm (3.5 x 5.6 x 1.8")
Weight910 g (32 oz.)
Casingwall mounted, built-in pump, IP65 rated