Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

FC230B

FC230B

Food grade PVDF pH electrode

Dedicated PVDF combination pH electrode, measuring range: 0 to 12 pH, temperature range: 0 to 50°C, 32 to 122°F

Product Overview

FC230B Special PVDF composite pH electrode Measuring range: 0 to 12 pH   Temp. range: 0 to 50℃; 32 to 122 ℉

Basic description

For food applications, PVDF electrode

Junction type Single junction, Ag/AgCI
Junction type/Flow rate Open
Recommended electrolyte

viscolene

Max. pressure

0.1bar

Measuring range 0 to 12 pH

Recommended sample

Temp. range

0 to 50℃

32 to 122 ℉

Sensor type

Conical, 6x10mm

Temp. sensor NO
Built-in amplifier NO
Electrode material PVDF
Connector/Cable length BNC connector/1 m cable length
Protective sleeve/Protective solution

Special/HI80300

Application

Meat, semi-frozen products

  • Hanna Instruments offers a wide variety of pH electrodes for many different applications. The type of glass used to sense pH, bulb shape, body material, connection type, reference type, and electrolyte used are just some of the design considerations.

  • FC230B uses low temperature (LT) glass, a conical bulb, a food-grade PVDF body, and an open junction with viscolene gel electrolyte.

  • Low temperature glass

Figure 1 Details:

  • Low temperature glass formulation

  • Compared to general purpose (GP) glass with a resistance of approximately 100 megohms, the glass tip uses a special LT glass formulation with a resistance of approximately 50 megohms. This is beneficial because many foods are stored at low temperatures. As the temperature of the glass in the sample decreases, the resistance of LT glass will increase, approaching the resistance of GP glass at ambient temperature. If GP glass is used, the resistance will increase above the optimum resistance for the high impedance input of the pH meter. FC230B is suitable for samples from 0 to 50°C.

Figure 2 Details:

  • Conical glass tip

  • The conical tip design penetrates solids, semi-solids, and emulsions to directly measure pH in food.

Figure 3 Details:

  • Stainless steel blade

  • An optional stainless steel blade is attached to the probe to easily penetrate meat even in frozen samples. Cutting into the meat will allow the pH glass and reference junction to contact the sample, allowing direct pH measurement without extensive sample preparation. FC098 (20 mm; 0.75 in) and FC099 (35 mm; 1.38 in) are a set of two stainless steel piercing blades to be used with the FC230B

Figure 4 Details:

  • PVDF body

  • Polyvinylidene fluoride (PVDF) is a food-grade plastic that resists most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength, and resistance to UV and nuclear radiation. PVDF also resists fungal growth.

Figure 5 Details:

  • Open junction reference

  • Suspended solids and proteins found in food can clog traditional ceramic reference junctions. This clogging will impede the measurement circuit between the indicating electrode and the internal reference, resulting in slow response times, unstable readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and the internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it less prone to clogging, resulting in fast response and stable readings.

  • Figure 6 Details: BNC connector

  • FC230B uses a BNC connector. This type of connector is universal because it can be used with any pH meter that has a female BNC probe input. Other types of connectors include DIN, threaded, T-type, and 3.5mm, etc. These types of connectors tend to be proprietary connectors for specific types of meters and are not interchangeable.

SKU FC230B
Product Name Foodcare pH Electrode for Meat and Semi-Frozen Products with BNC Connector - FC230B
Quote Required Yes
Measurement Range pH
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate open
Type of Electrolyte viscolene
Body Material PVDF
Tip / Shape conic (6 x 10 mm)
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 50°C (32 to 122°F) - LT
Body Length/Overall Length 36 mm / 164 mm
Temperature Sensor no
Outer Diameter 6 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Amplifier no
Recommended Use meat, semi-frozen products
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.