HI12923 is a glass body, refillable, single junction pH electrode with a quick connect DIN connector. This electrode has a triple ceramic junction in the outer reference cell and the conical pH sensing is made of low temperature glass. There is an integrated amplifier and built-in temperature sensor for automatic temperature compensated pH readings.
-
The design considerations of HI12923 are ideal for pH measurement in soil and soil slurries. HI12923 is designed for use with HANNA's HI99121 portable pH meter.
-
HI12923 uses low temperature (LT) glass, conical bulb, glass body, triple ceramic junction, refillable 3.5M KCl + AgCl.
Low Temperature Glass Formulation
The glass uses a special LT glass formulation that has a lower resistance of approximately 50 megohms compared to general purpose (GP) with a resistance of approximately 100 megohms. When the sample is at low temperature, as the glass temperature decreases, the resistance of the LT glass will increase approaching that of GP glass at ambient temperature. If GP glass were used, the resistance would increase to a level above the resistance of the pH meter's high impedance input. HI1292D is suitable for a measurement range of -5 to 70oC.
Conical Bulb
The conical design allows penetration into solids, semi-solids, and emulsions. HI12923 is ideal for directly measuring pH in soil and soil slurries.
Glass Body
The glass of HI12923 resists many harsh chemicals and is easy to clean. The glass body also allows heat to be quickly transferred to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium, the more stable the reference potential.
| Order No. | HI12923 |
| Name | pH electrode for direct soil measurement - HI12923 |
| Quote required | Yes |
| Measuring range | pH |
| Measuring range | Single junction, Ag/AgCl |
| Junction type/flow rate | Ceramic, triple / 40-50 μL/h |
| Electrolyte type | 3.5M KCl + AgCl |
| Body material | Glass |
| Tip/shape | Conical (12 x 12 mm) |
| Matching pin | No |
| Max. pressure | 0.1 bar |
| Operating temperature range | -5 to 70°C (23 to 158°F) - LT |
| Body length/total length | 120 mm / 175.5 mm |
| Temp. sensor | Yes |
| Outer diameter | 12 mm |
| Cable | 7-pole; 1 m |
| Connector type | Quick connect DIN connector |
| Amplifier | Yes |
| Recommended use | Direct soil pH measurement, soil samples, soil solutions |
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments