Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI1414D/50

HI1414D/50

Flat-tip glass combination pH electrode

HANNA Instruments HI1414D/50
Flat-tip pH electrode for skin and scalp with DIN connector

Product Overview

  • HI1414D/50 is a glass body, single reference junction pH electrode made with low temperature glass and a DIN connector. This preamplified electrode features a built-in temperature sensor for temperature compensated measurements in a single probe design.

  • The electrode has a unique open junction design in which there is a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell. The open junction design resists clogging and the probe’s flat tip makes it ideal for pH measurements on surfaces such as skin, leather, and paper. The HI1414D/50 is recommended for use with Hanna’s HI99181 pH meter.

  • Open junction

  • Flat tip

  • Built-in temperature sensor

  • Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH, bulb shape, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

  • The HI1414D/50 uses low temperature (LT) glass, flat tip bulb, glass body, and open junction with viscolene gel electrolyte.

Image 1 Details:

  • Low Temperature Glass Formulation

  • The glass tip uses a special LT glass formulation with a resistance of about 50 megohms compared to general purpose (GP) with a resistance of about 100 megohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass in the sample decreases, the resistance of the LT glass will increase approaching that of GP glass at ambient temperature. If GP glass were used, the resistance would increase to above the optimum resistance for the high impedance input of a pH meter. The HI1414D/50 is suitable to use with samples that measure from 0 to 50°C.

,

Image 2 Details:

  • Flat Glass Tip

  • A flat tip is recommended to optimize surface contact with skin, leather, paper, and samples that are not easily penetrated.

Image 3 Details:

  • Glass Body

  • The glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium, the more stable the reference potential.

Image 4 Details:

  • Open Junction Reference

  • Suspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time, erratic readings, and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impervious to clogging, thus providing fast response and stable readings.

Image 5 Details:

  • DIN Connector

  • The HI1414D/50 uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The HI1414D/50 is recommended for use with Hanna’s HI99181 pH meter. Other types of connectors include BNC, screw-type, T-type, and 3.5mm to name a few.

SKU HI1414D/50
Product Name Flat Tip pH Electrode for Skin and Scalp with DIN Connector - HI1414D/50
Quote Required Yes
Measurement Range pH
Reference Cell Type single, Ag/AgCl
Junction Type/Flow Rate open
Type of Electrolyte viscolene
Body Material glass
Tip / Shape flat
Matching Pin no
Max. Pressure 0.1 bar
Temperature Operating Range 0 to 50°C (32 to 122°F)
Body Length/Overall Length 50 mm / 93.5 mm
Temperature Sensor yes
Outer Diameter 12 mm
Cable 7-pole; 1 m (3.3')
Connector Type DIN
Amplifier yes
Recommended Use scalp, skin
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.