Product Overview
HI2020-02
-
dge@Multiparameter pH Meter
-
The Edge@tablet-style meter is a breakthrough design and the pinnacle of Hanna's vision, design capability, integrated production, and world-class R&D. The Edge meter is only 0.5 thick yet feature-rich, capable of meeting the needs of a large number of customers. For those who prefer very simple operation, there is a basic mode of operation with a simple menu and options. For those who need advanced features, there is a fully featured standard mode of operation. The Edge HI2020 pH kit can be upgraded at any time by adding additional probes to measure conductivity or dissolved oxygen
| SKU | HI2020-02 |
|---|---|
| Product Name | edge® Multiparameter pH Meter - HI2020 |
| Quote Required | Yes |
| pH Range | -2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV |
| pH Resolution | 0.001 pH, 0.01 pH, 0.1 mV |
| pH Accuracy | ±0.002 pH, ±0.01 pH, ±0.2 mV |
| pH Calibration | 5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01 |
| pH Temperature Compensation | ATC |
| pH CAL Check (electrode diagnostics) | Probe condition, response time, glass and reference junction diagnostics ( HI 11311 & HI 12301 only) |
| EC Range | 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)** |
| EC Resolution | 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm |
| EC Accuracy | ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater) |
| EC Calibration | 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm |
| TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**, with 0.80 conversion factor |
| TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
| TDS Accuracy | ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) |
| TDS Calibration | through EC calibration |
| EC/TDS Temperature Compensation | ATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC |
| Temperature Correction Coefficient | 0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C |
| EC to TDS Conversion Factor | 0.40 to 0.80 |
| Salinity (% NaCl) Range | 0.0 to 400.0% NaCl*** |
| Salinity (% NaCl) Resolution | 0.1% NaCl |
| Salinity (% NaCl) Accuracy | ±1% of reading (@25ºC/77ºF) |
| Salinity (% NaCl) Calibration | 1 point with HI 7037L 100% NaCl sea water standard |
| Salinity (PSU) Range | 2.00 to 42.00 PSU*** |
| Salinity (PSU) Resolution | 0.01 PSU |
| Salinity (PSU) Accuracy | ±1% of reading (@25ºC/77ºF) |
| Salinity (PSU) Calibration | through EC calibration |
| Salinity Range | 0.0 to 80.0 g/L*** |
| Salinity Resolution (ppt) | 0.01 g/L |
| Salinity Accuracy (ppt) | ±1% of reading (@25ºC/77ºF) |
| Salinity Calibration (ppt) | through EC calibration |
| Dissolved Oxygen Range | 0.00 to 45.00 ppm (mg/L), 0.0 up to 300.0% saturation |
| Dissolved Oxygen Resolution | 0.01 ppm, 0.1% saturation |
| Dissolved Oxygen Accuracy | ±1 digit, ±1.5% of reading |
| Dissolved Oxygen Calibration | one or two points at 0% (HI 7040 solution) and 100% (in air) |
| Dissolved Oxygen Temperature Compensation | ATC |
| Salinity Compensation | 0 to 40 g/L (with 1 g/L resolution) |
| Altitude Compensation | -500 to 4000 m (with 100 m resolution) |
| Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F |
| Temperature Resolution | 0.1 °C, 0.1 °F |
| Temperature Accuracy | ±0.5 °C, ±0.9 °F |
| pH Electrode | HI11310 pH electrode (included) |
| Logging Type | Manual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots) |
| Logging Memory | up to 1000*** records |
| Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
| Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
| Power Supply | 230VAC to 5 VDC adapter (included) |
| Environment | 0 to 50°C (32 to 122°F), RH max 95% non-condensing |
| Dimensions | 202 x 140 x 12.7mm (8” x 5.5” x 0.5”) |
| Weight | 250 g (8.82 oz) |
| Ordering Information | HI2020 pH kit includes |
| Notes | * temperature limits will be reduced to actual probe/sensor limits |
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments