Product Overview
edge's breakthrough design is the culmination of Hanna's vision, design capabilities, integrated production and advanced R&D. The edge meter is only 0.5" thick yet rich in features to meet the demands of a vast array of customers. For those that prefer very simple operation, there is a basic mode operation with simplified menu and options while for those who need advanced functionality there is a full featured standard operating mode. The edge HI2030 EC/TDS/Salinity kit can be upgraded at any time with additional probes to measure pH or Dissolved Oxygen.

edge uses advanced digital electrodes with built-in microchips that store calibration information and automatically transfer it to the meter when connected.

-
Digital Electrodes
-
edge electrodes are highly advanced featuring a built-in microchip that stores calibration information that edge automatically retrieves once the electrode is plugged in. These digital electrodes also feature an easy-to-plug 3.5 mm connector so you never have to worry about right angles or aligning pins.

-
Four Ring Probe
-
The HI2030 edge EC/TDS/Salinity meter is supplied with the HI763100 four ring platinum conductivity probe that features a built-in temperature sensor for automatic temperature compensated measurements. Compared to amperometric bipolar probes that have a limited range and can be affected by polarization effects, four ring technology allows for a wide range of measurement using a single probe. The HI763100 probe features a glass and PVDF body with a PEI (Polyetherimide) sleeve. Both materials offer excellent resistance to many aggressive chemicals.

-
3.5 mm Probe Input
-
Plugging an electrode in has never been simpler, no alignment, no broken pins, just connect the 3.5 mm plug and get started.

edge® is incredibly versatile. It can be used in a variety of environments in numerous ways without taking up the space of a traditional benchtop meter.

-
Wall Mount
-
Using the wall mount bracket (included), edge can be placed on a wall leaving zero footprint on the countertop space. The bracket has a built-in connector to power edge and charge the battery. edge's zero footprint is designed to save you valuable benchtop space.

-
Holder and Electrode Holder
-
edge is supplied with a benchtop holder with an adjustable swivel electrode holder to charge and secure edge in place at an optimal viewing angle.

edge® is incredibly thin, weighs only 8.8 ounces, has an 8 hour battery life and features dual USB inputs.

-
Two USB Ports
-
edge includes a standard USB for exporting data with a flash drive and a second micro USB port for connecting to a computer for file export and charging edge when the holder is not available.

-
Data Logging
-
edge allows you to store up to 1000 log records of data. Data can be logged on demand (200 records), on stability (200 records) or at a predefined interval (600 records). Stored information includes the current reading, date, time and GLP data.

-
Basic Mode
-
edge offers a basic mode and a standard mode. In basic mode, edge functions as an EC meter with reduced functionality to simplify operation. In basic mode, the meter only allows automatic temperature compensation during calibration, automatic range adjustment of readings and automatic cell factor correction. The temperature correction coefficient is fixed at 1.9%/°C and interval logging cannot be performed. In standard mode, the user has the option to change these functions.
Video

| SKU | HI2030-02 |
|---|---|
| Product Name | edge® Multiparameter EC/TDS/Salinity Meter - HI2030 |
| Quote Required | Yes |
| pH Range | -2.00 to 16.00 pH, -2.000 to 16.000 pH* |
| pH Resolution | 0.01 pH, 0.001 pH* |
| pH Accuracy | ±0.01pH, ±0.002 pH* |
| pH Calibration | Automatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers* |
| pH Temperature Compensation | Automatic -5 to 100º C (23 to 212º F) (using integral temperature sensor) |
| EC Range | 0.00 to 29.99 μS/cm, 3.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm, absolute conductivity ‡ |
| EC Resolution | 0.01 μS/cm, 00.1 μS/cm, 0.01 μS/cm, 0.01 mS/cm, 00.1 mS/cm |
| EC Accuracy | ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater) |
| EC Calibration | 1 Cell Factor calibration; 6 standards available |
| TDS Range | 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150. to 1499. ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L absolute TDS ‡ (with 0.80 factor) |
| TDS Resolution | 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L |
| TDS Accuracy | ±1% of reading (±0.03 ppm or 1 digit, whichever is greater) |
| TDS Calibration | through EC calibration |
| EC/TDS Temperature Compensation | Automatic -5 to 100 ºC (23 to 212 ºF); NoTC - can be selected to measure absolute conductivity. |
| Temperature Correction Coefficient | 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC |
| EC to TDS Conversion Factor | 0.40 to 0.80 (default value is 0.50) |
| Salinity (% NaCl) Range | 0.0 to 400.0% NaCl * |
| Salinity (% NaCl) Resolution | 0.1% NaCl |
| Salinity (% NaCl) Accuracy | ±1% of reading |
| Salinity (% NaCl) Calibration | Single point with HI 7037L Standard |
| Salinity (PSU) Range | 2.00 to 42.00 PSU * |
| Salinity (PSU) Resolution | 0.01 PSU, |
| Salinity (PSU) Accuracy | ±1% of reading |
| Salinity Range | 0.0 to 80.0 g/L * |
| Salinity Resolution (ppt) | 0.01 g/L |
| Salinity Accuracy (ppt) | ±1% of reading |
| Dissolved Oxygen Measurement Type | polarographic |
| Dissolved Oxygen Range | 0.00 to 45.00 ppm (mg/L), 0.0 to 300.0% |
| Dissolved Oxygen Resolution | 0.01 ppm (mg/L), 0.1% |
| Dissolved Oxygen Accuracy | ±1.5% of reading |
| Dissolved Oxygen Calibration | One or two points at 0% (HI 7040) and 100% (water saturated air) |
| Dissolved Oxygen Temperature Compensation | 0.0 to 50.0 ºC (32.0 to 122 ºF) |
| Salinity Compensation | 0 to 40 g/L 1 g/L |
| Altitude Compensation | -500 to 4,000 m (-1640 to 13120’) 100 m (328’) |
| Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F |
| Temperature Resolution | 0.1 °C, 0.1 °F |
| Temperature Accuracy | ±0.5 °C, ±1.0 °F |
| EC/TDS Probe | HI 763100 EC/temperature probe |
| Logging Type | Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot |
| Logging Memory | Up to 1000 records |
| Connectivity | 1 micro USB port for charging and PC connectivity, 1 USB port for storage |
| GLP | yes |
| Battery Type/Life | Built-in rechargeable battery with up to 8 hours of continuous use |
| Power Supply | 5 VDC adapter (included) |
| Environment | 0 to 50°C (32 to 122°F), RH max 95% non-condensing |
| Dimensions | 202 x 140 x 12.7mm (8” x 5.5” x 0.5”) |
| Weight | 250 g (8.82 oz) |
| Ordering Information | HI2030 EC kit includes |
| Notes | * temperature limits will be reduced to actual probe/sensor limits |
Manuals and documentation
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsBluetooth smart pH meter
HANNA Instruments