Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI2631-02

HI2631-02
HI-2631 Conductivity Benchtop meter with Data Logging
HANNA Instruments HI2631-02
HI-2631 Conductivity Benchtop meter with Data Logging HI-2631 benchtop meter enables fast, accurate measurements utilising the Hanna Instruments digital electrode for conductivity (HI-763100) which in

Overview

HI-2631 Conductivity Benchtop meter with Data Logging HI-2631 benchtop meter enables fast, accurate measurements utilising the Hanna Instruments digital electrode for conductivity (HI-763100) which includes an integral temperature sensor. Each digital electrode has a unique serial number and the parameter that it measures is automatically identified by the meter. The 2631 measures conductivity and TDS while adding salinity measurement and calibration along with data logging capabilities.

The intuitive design simplifies configuration, calibration, measurement, data logging and transfer of data to a USB thumb drive or computer. The benchtop meter offers a Basic Mode that streamlines measurement configuration and is useful for routine applications. Additionally, the HI-2631 can be used in Standard Operating Mode, where all features and capabilities are enabled.

The meter has a large display with capacitive keys which features a 5.5” (14 cm) LCD. The large display provides a 130 ° wide viewing angle. Main feature points Automatic parameter recognition EC choice of measurement unit: Conductivity: µS/cm, mS/cm TDS - ppm (mg/L), g/L Salinity - NaCl, PSU, g/L Adjustable resolution for EC measurements Basic mode for simplified operation Dedicated GLP key GLP data included with logged data Simplified data transfer to a PC Internal clock and date Key Features Digital probe input - simply connect each probe via the 3.5 mm jack, Digital Smart Electrodes are automatically recognised.

Clear, full text readout - The HI-2631 presents clear, detailed text prompts at the bottom section of the screen. Two operating modes - HI-2631 can be used in Standard or Basic Operating Modes. Standard Mode enables all features while Basic Mode displays a simplified screen and features which is ideal for routine measurements.

Data logging - The HI-2631 provides ample data storage capacity, allowing you to save up to 1000 log records. Each data set comprehensively includes readings, GLP information, as well as date and time stamps. GLP - The sensor retains data from the most recent calibration, including date, time, and buffers utilised.

When connected to the HI-2631, this GLP information is automatically transferred. Capacitive touch keypad - HI-2631 features sensitive capacitive touch buttons for accurate keystrokes for navigating menus and screens. Since they are part of the screen, the buttons can never get clogged with sample residue.

Easy to read LCD - HI-2631 features a 5.5” (14 cm) LCD display that you can clearly view from over 5 m (16.4’). The large display, with its wide 130° viewing angle, provides one of the easiest to read LCDs in the industry. USB-C port for charging and data transfer - The HI-2631 features a streamlined USB-C port that facilitates charging the integrated rechargeable battery, transferring data to your computer, and exporting files directly to a flash drive.

What's included: HI-763100 digital conductivity electrode HI-764026 Electrode holder with the following accessories: base plate with integrated pivot pin; cable holder clip, attached 12880 µS/cm calibration solution, x 2 sachets 1413 µS/cm calibration solution, x 4 sachets 5000 µS/cm calibration solution, x 2 sachets Electrode rinse solution x 2 sachets HI-920018 - 1.5m USB-C to USB-C cable USB-C power adapter Instrument quality certificate Probe / electrode quality certificate Battery safety insert Quick reference guide with QR code for instruction manual download Warranty - Meter has 2 years. 6 months from date of purchase for electrodes and probes More accessories to buy separately Electrodes HI-763100 Digital EC / temperature probe More solutions to buy separately Conductivity solutions HI-7030L 12880 µS/cm calibration solution, 500 mL HI-7030M 12880 µS/cm calibration solution, 230 mL HI-7031L 1413 µS/cm calibration solution, 500 mL HI-7031M 1413 µS/cm calibration solution, 230 mL HI-7033L 84 µS/cm calibration solution, 500 mL HI-7033M 84 µS/cm calibration solution, 230 mL HI-7034L 80000 µS/cm calibration solution, 500 mL HI-7034M 80000 µS/cm calibration solution, 230 mL HI-7035L 111800 µS/cm calibration solution, 500 mL HI-7035M 111800 µS/cm calibration solution, 230 mL HI-7039L 5000 µS/cm calibration solution, 500 mL HI-7039M 5000 µS/cm calibration solution, 230 mL HI-7037L 100% NaCl sea water standard solution, 500 mL Other useful accessories HI-764026 Electrode holder for HI-2600 family Models in the series HI-2600 pH, EC, DO Benchtop Meter with Data Logging HI-2620 pH and ORP Benchtop Meter HI-2621 pH and ORP Benchtop Meter with Data Logging HI-2630 EC & TDS Benchtop Meter HI-2631 EC, TDS and Salinity Benchtop Meter with Data Logging HI-2640 Dissolved Oxygen Benchtop Meter HI-2641 Dissolved Oxygen Benchtop Meter with Data Logging

Specifications

ParameterValue
SKUHI2631-02
EC - using HI-763100 four-ring conductivity probe
EC Range0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm, and absolute conductivity (TDS) is the conductivity value without temperature compensation
Resolution0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy (@25°C)±1% of reading (±0.5 µS/cm or 1 digit, whichever is greater)
CalibrationCell factor calibration; six standards available: 84µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 118.8 mS/cm, one point offset: 0.00 µS/cm
Temperature CompensationAutomatic, -5 to 100.0°C; NoTC, can be selected to measure absolute conductivity
Temperature Coefficient0.00 to 6.00%/°C (for EC and TDS only), default value is 1.90%/°C
TDS - using HI-763100 four-ring conductivity probe
TDS Range0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L; 15.0 to 100.0 g/L; up to 400.0 g/L absolute TDS using 0.80 conversion factor
TDS Factor in Standard Mode0.40 to 0.80 (default value is 0.50)
Salinity - using HI-763100 four-ring conductivity probe
Salinity Range0.0 to 400.0 % NaCl; 2.00 to 42.00 PSU; 0.00 to 80.00 g/L
Calibration % NaCl onlyone point with HI-7037 standard
Temperature
Temperature Range-20.0 to 120.0 °C
Accuracy±0.5°C
Additional Specifications
LoggingUp to 1000 (standard mode) (400) records organised in: • Manual log-on demand, maximum 200 logs • Manual log-on-stability, maximum 200 logs • Interval logging in Standard Mode, maximum 600 logs (100 lots)
PC InterfaceUSB-C
Storage InterfaceUSB-C
Power supplyUSB Type C (5 VDC; 500mA)
Environment0 to 50˚C; Maximum 95% RH non-condensing
Dimensions205 x 160 x 77 mm
WeightApproximately 0.85 kg

Accessories

  • HI-7034L: HI-7034L 500ml 80 000uS bottle of Conductivity solution
  • HI-7035L: HI-7035L 111 800 uS/cm Conductivity Solution, 500 mL bottle
  • HI-7039L: HI-7039L 5000 uS/cm Conductivity Solution, 500mL bottle
  • HI-7033L: HI-7033L 84uS/cm Conductivity Calibration Solution, 500mL
  • HI-7031L: HI-7031L 1413uS/cm Conductivity Calibration Solution, 500mL
  • HI-7030L: HI-7030L Conductivity Calibration Solution 12880uS/cm, 500mL