The HI36183 is a glass body, refillable, single junction ORP electrode with a built-in temperature sensor and a quick connect DIN connector. This type of connector is proprietary to specific meters such as the HI98190. The HI36183 ORP electrode features a single ceramic junction in the outer reference cell and the ORP sensing pin is made of platinum. This design consideration is ideal for laboratory and general purpose redox measurements.
The HI36183 uses a platinum pin, glass body, single ceramic junction, refillable 3.5M KCl + AgCl.
Platinum Sensing Pin
The HI36183 ORP sensor is made of platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange, a property called high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. Platinum sensors are usually chosen because it is mechanically simple and safe to produce. Platinum can be welded to glass and has a similar thermal coefficient.
Glass Body
A glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a rapid transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster equilibrium is reached, the more stable the reference potential.
Single Ceramic Junction
The outer junction of an electrode, also known as a salt bridge, is a necessary component of the electrical circuit. The movement of ions must flow through the junction for a stable reading. The outer reference has a single ceramic frit. Ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL/hour. Other junction types have higher flow rates and are made of different materials.
Refillable
The HI36183 is a refillable probe. Since it is a single junction ORP electrode, the fill solution is HI7071 3.5M KCl + AgCl. If using a refillable ORP electrode, the fill cap should be removed prior to measurement. Removing the cap creates positive head pressure in the reference cell allowing for a higher flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.
Quick Connect DIN Connector
The HI36183 uses a quick connect DIN connector that makes installing and removing the probe simple and easy. This type of connector is proprietary to the meter. Please refer to the specifications table for compatible meters.
| Order No. | HI36183 |
| Name | Glass body ORP electrode with quick connect DIN connector - HI36183 |
| Quote Required | Yes |
| Measuring range | ORP |
| Reference cell type | Single, Ag/AgCl |
| Junction type/flow rate | Ceramic, single / 15-20 μL/h |
| Refill electrolyte | 3.5M KCl + AgCl |
| Body material | Glass |
| Tip/shape | Platinum pin |
| Max pressure | 0.1 bar |
| Operating temperature range | -5 to 70°C (23 to 158°F) |
| Temp. sensor | Yes |
| Cable | 5-pole; 1 m |
| Connector type | Quick connect DIN |
| Amplifier | Yes |
| Recommended use | General laboratory |
| ORP sensing type | Platinum |
Case Studies
Municipal Wastewater Treatment · Hanna — Stock Configuration Case
Project Overview
The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.
Technical Challenges
What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.
Configuration
Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.
Performance
After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.
Food & Beverage · Hanna — Stock Configuration Case
Site Conditions
This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.
The Problem
The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.
What We Did
We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.
Operating Outcome
In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.
Chemical & Pharmaceutical · Hanna — Stock Configuration Case
Application Context
reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.
Process Constraints
corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.
Delivery Approach
Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.
Field Results
Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.
Power & Energy · Hanna — Stock Configuration Case
Customer Profile
The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.
Key Difficulties
Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.
Implementation
The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.
Customer Benefit
In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.
Related Products
HANNA InstrumentsPortable multi-range conductivity meter
HANNA InstrumentsLow range ammonia nitrogen portable photometer
HANNA InstrumentsPortable multi-range turbidimeter
HANNA InstrumentsSaltwater aquarium salinity meter
HANNA InstrumentsPortable honey color analyzer
HANNA InstrumentsPortable free chlorine photometer
HANNA InstrumentsPortable free and total chlorine photometer
HANNA Instruments