Ozone concentration test kit

Ozone test kit

Product Overview

  • HI38054 is a chemical test kit for determining ozone concentration in samples within the range of 0.0 to 2.3 mg/L. HI38054 is supplied with all reagents and equipment required to perform two types of analysis, including the Checker® disc for accurate determination. The reagents included in the test kit are sufficient for approximately 100 tests.

  • Features at a Glance

  • Complete Setup

  • All required materials are included in the test kit, such as glass vials, plastic pipettes, reagent packets, and Checker® disc.

  • High Resolution

  • Readings from 0.0 to 2.3 mg/L are determined with a resolution of 0.1 mg/L.

  • Replaceable Reagents

  • There is no need to purchase a new kit once the reagents are used up. HI38054-100 can be ordered to replace the reagents supplied with the kit.

  • Significance of Use

  • Ozone is an oxidizing agent used in many industrial and consumer applications. Industrial applications include disinfection of drinking water, wastewater, and food processing rinse water. Ozone is a mild bleaching agent used in the textile industry. Ozone can also be used in oxidation reactions, including precipitation of manganese from drinking water and oxidation of cyanide in electroplating wastewater. Ozone is a versatile oxidizing agent, whether as a disinfectant, deodorizer, or bleaching agent.

SKU HI38054
Product Name HI38054 Ozone Test Kit
Quote Required Yes
Ozone Measurement Type Checker Disc
Ozone Range 0.0 to 2.3 mg/L
Ozone Resolution 0.1 mg/L
Ozone Method DPD
Ozone Number of Tests 100
Weight 966 g (34.1 oz)
Dimensions 235x175x115 mm (9.2x6.9x4.5")
Ordering Information HI38054 test kit supplied with 100 packets of ozone reagent, 500 mL deionized water, checker disc, glass vials with caps (2), and 3 mL plastic pipette.
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.