HI4003

HI4003
Cadmium Half-Cell ISE
The mixed cadmium sulphide/silver sulphide sensing pellet produces a potential change due to the cadmium ion exchange between the inorganic pellet membrane and the sample. The internal sensing element

Overview

The mixed cadmium sulphide/silver sulphide sensing pellet produces a potential change due to the cadmium ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable epoxy body. The HI-4003 is ideal for a variety of applications in electroplating, battery construction, and in the laboratory.

Solid state sensor Detection from 0.01 to 11,200 mg/L Cd2+ For use with HI-5315 reference half-cell The HI-4003 cadmium ion selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed cadmium sulphide/silver sulphide sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.

Hanna’s solid state half-cell ISEs are designed for use with the HI-5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution.

A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary. For the HI-4003 to measure cadmium accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the HI-4000-00 ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free cadmium ions can be measured.

Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI-4003 cadmium solid state ISE can measure from 0.1µM (0.01 mg/L) to 0.1M (11,200 mg/L).

Specifications

ParameterValue
SKUHI4003
ParameterCadmium
TypeSolid-state; Half-cell
Measurement Range1M to 1X 10 -7 M 11200 to 0.01 ppm
Optimum pH Range2 to 12.5
Temperature Range0 to 80°C
Approximate Slope+28
Body O.D.12 mm
Insertion Length120 mm
Body MaterialEpoxy
Cable1m coaxial
ConnectorBNC
Possible ApplicationsUsed as an indicator for titrations using chelates

Accessories

  • HI-4003-01: HI-4003-01 0.1 M Cadmium Standard, 500 mL