Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI4105

HI4105
Carbon Dioxide Combination ISE Electrode
The HI-4105 is a gas sensing, combination ion selective electrode (ISE) for the determination of carbon dioxide (CO 2 ) in solution. Its PTFE membrane allows for carbon dioxide gas diffusion into a th

Overview

The HI-4105 is a gas sensing, combination ion selective electrode (ISE) for the determination of carbon dioxide (CO 2 ) in solution. Its PTFE membrane allows for carbon dioxide gas diffusion into a thin layer of internal electrolyte. The internal sensing elements are within a durable Delrin® body.

The HI-4105 Carbon Dioxide Ion Selective Electrode is a complete potentiometric cell that contains both a silver/silver chloride (Ag/AgCl) reference and a pH measurement element. These elements are housed within a plastic body with a Chloride ion-containing electrolyte, isolated from the sample by a gas permeable membrane made of polytetrafluoroethylene (PTFE). For the HI-4105 to measure carbon dioxide accurately, it is important that the pH of the calibration standards and sample be lowered with the carbon dioxide ionic strength adjuster (ISA) solution.

The carbon dioxide ISA ensures the pH of solutions is kept between pH 4.2 and 5.2. In this pH range, the carbonate and bicarbonate in solution are converted to carbon dioxide for an accurate measurement. The HI-4105 carbon dioxide gas sensing ISE can measure from 400µM (17.6 mg/L) to 0.02M (880 mg/L).

Key features: Replaceable PTFE Membranes - Gas sensing ISEs are combination electrodes that detect dissolved gases in a solution. The sensing element is separated from the sample solution by a gas permeable, PTFE membrane that is easy to replace. Durable Delrin® Body - The probe body is composed of durable Delrin plastic.

BNC Connection - The HI-4105 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.

Specifications

ParameterValue
SKUHI4105
ParameterCarbon Dioxide
TypeGas Sensing; Combination
Measurement Range1X 10 -2 M to 1X 10 -4 M 440 to 4.4 ppm
Optimum pH Range4.2 to 5.2
Temperature Range0 to 40°C
Approximate Slope+54
Body O.D.12 mm
Insertion Length120 mm
Body MaterialDelrin
Cable1m coaxial
ConnectorBNC
Possible ApplicationsDetermination of carbonates as CO 2 in water, soft drinks and wine samples

Accessories

  • HI-4005-00: HI-4005-00 Carbon Dioxide ISA
  • HI-4005-40: HI-4005-40 Carbon Dioxide Filling Solution
  • HI-4005-45: HI-4005-45 Conditioning and Storage Solution for Carbon Dioxide ISE
  • HI-4005-53: HI-4005-53 Carbon Dioxide Membrane Kit (3 caps)