Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI4107

HI4107

Chloride ion solid-state membrane selective electrode

Chloride combination ion-selective electrode (ISE)

Product Overview

HI4107 is a solid-state combination ion-selective electrode (ISE) for the determination of chloride (Cl-) in solutions. The silver chloride sensing pellet generates a potential change due to the chloride ion exchange between the inorganic pellet membrane and the sample. The internal sensing element is housed within a durable polyetherimide (PEI) body.

  • HI4107 is ideal for a variety of applications in food and beverage, agriculture, and water treatment.

  • Solid-state sensor

  • Tapered cone geometry

  • Detection from 1.8 to 35500 mg/L Cl-

  • The HI4107 chloride ion-selective electrode is a complete potentiometric cell that contains a silver/silver chloride (Ag/AgCl) reference located within a PEI plastic body with potassium nitrate electrolyte. The internal element is isolated from the sample by a compressed silver chloride sensing membrane.

  • Hanna's solid-state combination ISE features a conical connection design. The sensor's skirt cone geometry forms a liquid junction with the test solution at the tip of the connection cone, producing a highly stable reference potential and a consistent flow rate of electrolyte into the solution. A simple press on the top of the ISE makes it easy to empty the electrolyte fill solution and replace it when necessary.

  • For the HI4107 to accurately measure chloride, it is important to adjust the ionic strength of both standards and samples to a high and constant value using a halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant, so the concentration of free chloride ions can be measured. Measuring all solutions at a constant ionic strength reduces errors between measurements. The HI4107 chloride solid-state ISE has a measuring range of 50µM (1.8 mg/L) to 1M (35500 mg/L).

  • Conversion table for Cl-

  • Multiply

  • moles/L (M) to ppm (mg/L)

  • 3.500 x 104

  • ppm (mg/L) to M (moles/L)

  • 2.857 x 10-5

  • Features at a glance

  • Fixed sensing module - The combination solid-state ISE is an electrode for detecting free ions in solution. The highly insoluble compressed sensing pellet is attached to the electrode via a fixed sensing module for ease of use.

  • Durable PEI body - The probe body is made of durable polyetherimide (PEI) plastic.

  • BNC connection - The HI4107 has a universal BNC connector that easily connects to any benchtop meter with a female BNC probe input.

  • Theory of operation

  • Solid-state sensor electrodes generate a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. Equilibrium occurs because the membrane material has very limited solubility in the sample. When the ionic strength of the solution is fixed by adding ISA, the voltage is proportional to the concentration of free ions in the solution.

SKU HI4107
Product Name Chloride Combination Ion-Selective Electrode (ISE) - HI4107
Quote Required Yes
Description combination
Measurement Range chloride (Cl-) 1.0M to 5 x 10-5M, 35,500 to 1.8 mg/L (ppm)
Temperature Range 0 to 80 °C
Body Material PEI
Optimum pH Range pH 2 to 11
Body Length/Overall Length 120 mm
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Notes Approximate Slope -56 mV
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit