Glass body half-cell reference electrode

Glass-body calomel reference electrode

HI5412 is a glass body, refillable, double junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in an external reference cell and a calomel reference cell.

Glass Body

The glass body is ideal for laboratory use. The glass resists many harsh chemicals and is easy to clean. The glass body also allows heat to be transferred quickly to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium, the more stable the reference potential.

Single Ceramic Junction

The outer junction of the electrode, also known as the salt bridge, is a necessary component of the circuit. The movement of ions must flow through the junction to obtain a stable reading. The external reference has a single ceramic frit. Ceramic is a porous material that easily fuses with the glass body and has a similar coefficient of expansion. The flow rate of the single ceramic junction is 15-20 μL/hour. Other junction types have higher flow rates and are made of different materials.

Refillable

HI5412 is a refillable reference electrode. Since it is a double junction electrode, the filling solution is HI7082 3.5M KCl. This solution does not contain any silver, unlike single junction electrodes. The absence of silver will prevent any silver precipitate from forming at the junction and clogging it. A clogged junction will cause reading drift and instability. 

4 mm Connector

HI5412 uses a 4 mm banana connector. This type of connector easily plugs into the reference input of a suitable meter. Other types of connectors include BNC, DIN, screw type, T-type, and 3.5mm, etc. These types of connectors tend to be proprietary to a specific type of meter and are not interchangeable.

Order No. HI5412
Product Name Glass Body Calomel Reference Electrode - HI5412
Quote Required Yes
Reference Cell Type Single, Hg/Hg
Junction Type/Flow Rate Ceramic, single / 15-20 μL/h
Refill Electrolyte 3.5M KCl
Body Material Glass
Max. Pressure 0.1 bar
Operating Temp. Range -5 to 60°C (23 to 140°F)
Body Length/Total Length 120 mm / 175.5 mm
Outer Diameter 12 mm
Cable 1 m
Connector Type 4 mm banana
Recommended Use General purpose, titration
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.