Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI729

HI729
Fluoride Low Range Handheld Colorimeter, Checker HC
Fluoride is one of the few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking wate

Overview

Fluoride is one of the few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects. The HI-729 pocket checker is a simple and accurate way to measure low ranges of fluoride.

Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva which reduces the rate at which tooth enamel de-mineralises and increases the rate at which it re-mineralises in the early stages of cavities. A 1994 World Health Organisation expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate.

Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride. Key features Accurate and easy to use Adaptation of SPADNS method ±0.05 ppm ±5% of reading 0.01 ppm resolution Designed to work with Hanna reagents Large easy to read digits Auto shut-off Ideal for Water testing Quick on the spot analysis Supplied with 2 sample cuvettes with caps Reagents for 6 tests (re-ordering information HI-729-26 x 20 tests Syringe with tip 1 x 1.5V AAA battery Instructions Four steps. One click.

Instant Readout. 1. ‘Zero’ the Checker®HC with your vial inside 2.

Place a 10ml water sample into the vial and add your reagent 3. Place your vial into your Checker®HC 4. Press the button and read the results Use Calibration Check Set HI-729-11 with the Hi-729 Fluoride Low Range Handheld Colorimeter, Checker®HC.

Use reagent HI-729-26 with the Hi-729 Fluoride Low Range Handheld Colorimeter, Checker®HC, x 20 tests. Safety Data Sheets When using any form of chemical, such as Hanna reagents, it is important you download the relevant safety data sheet and make yourself aware of any precautions you should take when handling the chemical. You can access our library of safety data sheets and download a copy by following the link below.

Please note that the '-' in HI- products should be removed from all searches to find the correct information. CLICK HERE

Specifications

ParameterValue
SKUHI729
Range0.00 to 2.00 ppm
Resolution0.01 ppm
Accuracy @ 20°C±0.05 ppm ±5% of reading
Light SourceLED @ 575 nm
Light Detectorsilicon photocell
Environment0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type(1) 1.5V AAA
Auto-offafter two minutes of non-use and ten seconds after reading
Dimensions81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight64 g (2.25 oz.)
Methodadaptation of SPADNS method

Accessories

  • HI-729-11: HI-729-11 Fluoride Low Range Checker HC Calibration check set
  • HI-729-26: HI-729-26 Reagents for HI-729 Fluoride Low Range Checker HC
  • HI-731225: HI-731225 Cuvette Caps for Checker (Pack of 4)
  • HI-731318: HI-731318 Cuvette Cleaning Cloths x 4
  • HI-731321: HI-731321 Glass Cuvettes for Checkers & HI-832 HI-833 Series
  • HI-93703-50: HI-93703-50 Cuvette Cleaning Solution, 230ml

Manuals and documentation