Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI73127

HI73127

Direct insertion combination pH electrode

Single-junction polypropylene glass combination pH electrode, measuring range: 0 to 124 pH, sample temperature range: -5 to 50 °C (23 to 122 °F), sample pressure ≤ 0.1 bar;

Product Overview

  • HI73127 single-junction polypropylene glass composite pH electrode Measuring range: 0 to 124 pH, Sample temperature range: -5 to 50 °C (23 to 122 °F), Sample pressure ≤ 0.1 bar;

  • Suitable for HI98121, HI98127, HI98128, HI98129, HI98130, HI98131 and other Hanna brand dedicated meter series

  • Unique and durable single-junction plug-in composite pH electrode, HI73127 plug-in stainless steel connector composite pH electrode, easy to use, with the HI73128 dedicated removal tool, electrode replacement is quick and convenient.

  • When the junction ages, pull it out 1-2 mm (1/8") to renew the junction. The unique and durable junction extends the electrode service life, prolongs electrode service life, and reduces costs.

  • Note: Do not use distilled water or deionized water to store or soak the electrode, as this will cause the electrode sensor to fail

Order No. HI73127
Product Name Spare pH electrode for meters - HI73127
Quote Required Yes
Measuring range pH
Reference cell type Single, Ag/AgCl
Junction type/flow rate Cloth
Electrolyte type Gel
Body material Polypropylene
Tip/shape Spherical (diameter)
Max. pressure 0.1 bar
Operating temperature range -5 to 50°C (23 to 122°F)
Temp. sensor No
Connector type Pin
Amplifier No
Recommended use Field applications, general purpose
Municipal Wastewater Treatment

Municipal Wastewater Treatment · Hanna — Stock Configuration Case

Project Overview

The site is the inlet, biological and outlet stages of a municipal plant. The customer wanted Hanna properly configured on the existing plant, with the aim of covering portable and laboratory water testing with Hanna instruments.

Technical Challenges

What actually causes trouble is high solids and corrosive fractions, with large diurnal flow swings, and effluent parameters drift and probes foul with sludge and biofilm. All of this means the Hanna configuration has to involve selected by parameter set, accuracy and field portability.

Configuration

Supply and installation were organised through the stock channel: configuring from stock and delivered quickly. On site this meant selected by parameter set, accuracy and field portability, checked line by line against: stable compliance with Grade 1A discharge limits and online data reporting.

Performance

After commissioning the outcome is results available on site, reducing lab re-checks, and the readings are now used for process tuning.

Food & Beverage

Food & Beverage · Hanna — Stock Configuration Case

Site Conditions

This is a Food & Beverage customer whose plant is at dosing, pasteurising, filling and CIP stages. The main task was covering portable and laboratory water testing with Hanna instruments.

The Problem

The difficulty lies in syrups, dairy and beverages that scale easily, under strict hygienic requirements; at the same time frequent cleaning demands instruments that withstand hot CIP/SIP caustic cycles. Specification therefore means selected by parameter set, accuracy and field portability.

What We Did

We took a stock channel approach — configuring from stock and delivered quickly. Delivery was built around selected by parameter set, accuracy and field portability, with point-by-point checks on: food-safety and hygienic design per 3-A / EHEDG.

Operating Outcome

In service the system performs as intended — results available on site, reducing lab re-checks, with routine maintenance falling noticeably.

Chemical & Pharmaceutical

Chemical & Pharmaceutical · Hanna — Stock Configuration Case

Application Context

reactors, metering vessels and finished-product tanks is a typical Chemical & Pharmaceutical duty. The project started from Hanna, focusing on covering portable and laboratory water testing with Hanna instruments.

Process Constraints

corrosion plus Ex protection shortens instrument life and makes downtime costly, and highly corrosive media with solvents and crystallisation, partly in explosive atmospheres only amplify it. The Hanna specification must therefore cover selected by parameter set, accuracy and field portability.

Delivery Approach

Delivery was handled as the stock channel — configuring from stock and delivered quickly. Execution centred on selected by parameter set, accuracy and field portability, together with Ex certification and GMP traceability of records.

Field Results

Operation shows the benefit clearly — results available on site, reducing lab re-checks, with confidence in this measuring point improving markedly.

Power & Energy

Power & Energy · Hanna — Stock Configuration Case

Customer Profile

The typical setting in Power & Energy is boiler feedwater, turbine condensate and FGD/DeNOx systems. The measuring point is Hanna; the focus is covering portable and laboratory water testing with Hanna instruments.

Key Difficulties

Conditions are high temperature and pressure with both steam and saline water and, on top of that, drift under high temperature and pressure, with very costly unplanned outages, which a standard configuration cannot handle for long. The design therefore starts with selected by parameter set, accuracy and field portability.

Implementation

The scope ran through the stock channel: configuring from stock and delivered quickly. Technically it hinges on selected by parameter set, accuracy and field portability, and on these requirements: compliance with power-industry codes and unit availability targets.

Customer Benefit

In practice this means results available on site, reducing lab re-checks, which cut the workload on the site maintenance team.