Overview
About the IRIS iris features precise wavelength selection between 340 nm to 900 nm for complete method compliance and accuracy that is necessary in industries like professional laboratories, water treatment facilities, wineries, and more. Results are consistent and accurate with the high quality and uniquely designed optics system. Customisation options include multiple cuvette shapes and sizes, custom calibration curves, and methods.
Portable Replaceable tungsten-halogen lamp Can also measure Total suspended solids Vial reagents, no powder USB Flash Drive exports Built-in rechargeable Lithium Ion Battery Wide Wavelength Selection Auto Cuvette recognition Universal Cuvette Holder Favourite Methods option Superior design for superior results iris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm. With the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.
No need for measurement conversions Whether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need. Pre-programmed methods with the option to expand iris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started.
Simply update these methods by connecting to a computer or flash drive. Customise your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step.
For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers. Easily access your favourite methods directly from the home screen to save time. Built in timers make measuring seamless.
The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps. Worry free replacements iris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths.
Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing. Designed for dynamic environments iris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3,000 measurements, or 8 hours – well over a full day of use out in the field.
Quality data without the hassle Export your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software. Sort and share your data Save data as a .pdf or .csv for maximum data integrity or flexibility.
Have the freedom to choose the file format that is best for you. Menu navigation that makes sense Quickly navigate between screens with custom keys, and access your favourite methods directly from the home screen with our “favourite methods” feature. All of your important information is easily visible With a 6” display, the screen is large and easy to read.
The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements. Zero resistance with a capacitive touch pad Menu buttons are part of the display.
Built to be fully sealed and easy to clean, the meter recognises key touches even through gloves. Change sample size easily With its universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.
UPDATE for existing users: There is a new reagent addition and method for Total Phosphorus and Cationic surfactants available. If you want to use this reagent addition method, download the firmware here and click on the Software icon. Scroll down to the update required for the HI-801 or HI-802 Iris.
If you need any help with installation, please call our Lab team for more information. The original testing method for these parameters is still available if you prefer to test that way.
Specifications
| Parameter | Value |
|---|---|
| SKU | HI801-02 |
| Wavelength Range | 340 to 900 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1.5 nm |
| Measurement Modes | Transmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg/L, ppt, °f, °e, ppb, meq/L, μg/L, PCU, Pfund, pH, dKH, °dH, meq/kg or no measurement unit) |
| Wavelength Selection | automatic, based on the selected method (editable for user methods only) |
| Light Source | tungsten halogen lamp |
| Optical System | split beam sample and reference light detectors |
| Wavelength Calibration | Internal, automatic at power-on, visual feedback |
| Stray Light | smaller than 0.1% T at 340 nm with NaNO₂ |
| Spectral bandwidth | 5 nm (full width at half maximum) |
| Sample Cell | 16 mm round, 22 mm round, 13 mm vial, 10 mm square, 50 mm rectangular (with automatic detection) |
| Programs (Factory/User) | Up to 150 factory (85 pre-loaded); up to 100 user developed |
| Data Points Stored | Up to 9999 measured values |
| Export Capability | .csv file format, .pdf file format |
| Connectivity | (1) USB - A (mass storage host); (1) USB - B (mass storage device) |
| Battery Type / Life | 3000 measurements or 8 hours |
| Power Supply | 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery |
| Environment | 0 to 50 °C (32 to 122 °F); 0 to 95% RH |
| Dimensions | 155 x 205 x 322 mm |
| Weight | 3 kg (6.6 lbs) |
| Ordering Information | HI-801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate. |
| ABSORBANCE | |
| Range | 0.000 to 3.000 Abs |
| Resolution | 0.001 Abs |
| Accuracy (@25°C) | 5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs |
| Method | |
| Wavelength | |
| Reagent Code | |
| ALKALINITY | |
| ALKALINITY, MARINE | |
| ALUMINIUM | |
| AMMONIA, LOW RANGE | |
| AMMONIA, LOW RANGE – 13mm Vial | |
| Accuracy | ±0.10 mg/L or ±5% of reading at 25˚C, whichever is greater |
| cuvette type | 13mm diameter |
| AMMONIA, MEDIUM RANGE | |
| AMMONIA, HIGH RANGE | |
| AMMONIA, HIGH RANGE – 13mm Vial | |
| BROMINE | |
| CALCIUM | |
| CALCIUM, MARINE | |
| CHEMICAL OXYGEN DEMAND, LOW RANGE | |
| CHEMICAL OXYGEN DEMAND, MEDIUM RANGE | |
| CHEMICAL OXYGEN DEMAND, HIGH RANGE | |
| CHLORIDE | |
| CHLORINE DIOXIDE | |
| CHLORINE, FREE ULTRA LOW RANGE | |
| CHLORINE, FREE LOW RANGE | |
| CHLORINE, FREE HIGH RANGE | |
| CHLORINE, TOTAL ULTRA LOW RANGE | |
| CHLORINE, TOTAL LOW RANGE | |
| CHLORINE, TOTAL HIGH RANGE | |
| CHLORINE, TOTAL ULTRA HIGH RANGE | |
| CHROMIUM (VI), LOW RANGE | |
| CHROMIUM (VI), HIGH RANGE | |
| COLOUR OF WATER | |
| COPPER, LOW RANGE | |
| COPPER, HIGH RANGE | |
| CYANIDE | |
| CYANURIC ACID | |
| FLUORIDE, LOW RANGE | |
| FLUORIDE, HIGH RANGE | |
| HARDNESS, CALCIUM | |
| HARDNESS, MAGNESIUM | |
| HARDNESS, TOTAL LOW RANGE | |
| HARDNESS, TOTAL MEDIUM RANGE | |
| HARDNESS, TOTAL HIGH RANGE | |
| HYDRAZINE | |
| IODINE | |
| IRON, LOW RANGE | |
| IRON, HIGH RANGE | |
| MAGNESIUM | |
| MANGANESE, LOW RANGE | |
| MANGANESE, HIGH RANGE | |
| MAPLE SYRUP | |
| MOLYBDENUM | |
| NICKEL, LOW RANGE | |
| NICKEL, HIGH RANGE | |
| NITRATE | |
| NITRATE, CHROMOTROPIC ACID | |
| NITRITE, MARINE ULTRA LOW RANGE | |
| NITRITE, LOW RANGE | |
| NITRITE, HIGH RANGE | |
| NITROGEN, TOTAL LOW RANGE | |
| NITROGEN, TOTAL HIGH RANGE | |
| OXYGEN, DISSOLVED | |
| OXYGEN SCAVENGERS (CARBOHYDRAZIDE) | |
| OXYGEN SCAVENGERS (DIETHYLHYDROXYLAMINE)(DEHA) | |
| OXYGEN SCAVENGERS (HYDROQUINONE) | |
| OXYGEN SCAVENGERS (ISO-ASCORBIC ACID) | |
| OZONE | |
| pH | |
| PHOSPHORUS, MARINE ULTRA LOW RANGE | |
| PHOSPHATE, LOW RANGE | |
| PHOSPHATE, HIGH RANGE | |
| PHOSPHORUS, REACTIVE LOW RANGE | |
| PHOSPHORUS, REACTIVE HIGH RANGE | |
| PHOSPHORUS, ACID HYDROLYZABLE | |
| PHOSPHORUS, TOTAL LOW RANGE | |
| PHOSPHORUS, TOTAL HIGH RANGE | |
| POTASSIUM, LOW RANGE | |
| POTASSIUM, MEDIUM RANGE | |
| POTASSIUM, HIGH RANGE | |
| SILICA, LOW RANGE | |
| SILICA, HIGH RANGE | |
| SILVER | |
| SULPHATE | |
| SURFACTANTS, ANIONIC | |
| SURFACTANTS, CATIONIC | |
| SURFACTANTS, NONIONIC | |
| ZINC |
Accessories
- HI-7408020: HI-7408020 Protective Dust Cover for the HI-80X series of Spectrophotometers
- HI-7408014: HI-7408014 Replacement Tungsten Halogen Lamp for Iris Spectrophotometers
Related Products
HANNA InstrumentsEPA Compliant Turbidity and Free & Total Chlorine Meter
HANNA InstrumentsHardness, High Range Test Kit
HANNA InstrumentsAlkaline battery size AAA
HANNA InstrumentsFilter holder with Luer lock
HANNA InstrumentsSyringe 10mL with Luer Lock
Large pump head assembly
HANNA InstrumentsRugged Case for Waterproof Meters with Moulded Insert
HANNA Instruments