Instrumentation · Engineering · Package · PLC
0755-82221901 sales@ainstru.com

HI802-02

HI802-02
HI-802 Iris Visible Spectrophotometer with Barcode Reader
HI-802 Iris Visible Spectrophotometer with Barcode Reader The Iris Spectrophotometer from Hanna Instruments is an exceptionally accurate, reliable and repeatable solution for measurements across all v

Overview

HI-802 Iris Visible Spectrophotometer with Barcode Reader The Iris Spectrophotometer from Hanna Instruments is an exceptionally accurate, reliable and repeatable solution for measurements across all visible wavelengths. This compact, versatile instrument is suitable for measurement on the benchtop of a laboratory, when testing on-site and for measurement in the field, with full portability and a lithium-ion battery with charge for approximately 3,000 measurements. In addition to versatility, the Iris is also easy-to-use, with barcode recognition on Hanna liquid vial reagents to immediately identify the vial, allowing you to apply methods to specific samples and save time on testing.

A pre-programmed favourites menu and the ability to create completely custom curves inclusive of averaging allow the Iris to be customised to your requirements for efficient operation. Book a demonstration of the Hanna Iris Spectrophotometer with our experts today.

Iris Spectrophotometer Features Automatic vial recognition with barcode reader The HI-802 Iris features automatic recognition of compatible Hanna vial reagents, using a barcode reader to immediately set up and test. This system reduces time in testing, with no need to navigate menus. Simply insert the vial into the spectrophotometer to begin the testing process, reducing errors and ensuring the correct method is used every time.

Electronic Zero functionality Electronic zero functionality saves time and effort when testing. Store the Zero a single time for measurement with DI water blank correction, ensuring stable readings. Using this option allows you to bypass the interface, for fast, convenient and accurate testing with a shared single-zero that delivers fast results.

Exceptional accuracy with the Average Function Achieve exceptional accuracy in measurement with the Average Function, with compatible 13 mm vials completing a rotation with 256 readings for high precision in testing. The averaging option is available for both pre-programmed and custom methods, providing complete flexibility while ensuring accurate results from measurements. Over 100 pre-programmed methods The HI-802 Iris is pre-programmed with 90 commonly-used methods, with over 100 factory methods available to further improve the versatility of this spectrophotometer.

Add methods directly to the favourites menu for easy access, or utilise the barcode system with compatible Hanna cuvette reagents to automatically detect methods directly. Customise the Iris with up to 100 custom methods In addition to the existing methods, the Iris can be fully customised with your own methods to suit niche or less common requirements. Our expert team at Hanna can support you in programming curves for specific purposes, making the Iris an ideal solution for a wide range of industries and specialist applications.

Coverage for all visible wavelengths The Iris Spectrophotometer from Hanna is capable of testing across the entire spectral range of visible light from 340 nm to 900 nm. This offers comprehensive coverage for common analytical methods, with excellent flexibility to adapt Iris methods to specific regulatory or industry requirements. Comprehensive vial compatibility Hanna’s portable spectrophotometer includes a cuvette holder and multiple adaptors to expand the range of cuvettes that can be measured with the Iris.

These include 22 mm round and 5 cm path length rectangular vials as standard, with included adapters for 13 mm, 16 mm, and 10 mm cuvettes. The 13 mm adaptor includes a barcode reader and allows for the use of the Iris average function. Capacitive touchpad for use even with gloves A capacitive touchpad with optional audio feedback ensures the Iris is suited to many environments, from laboratories with strict sterility requirements to use in the field.

This spectrophotometer features a simple LCD display with button navigation, allowing you to change settings, switch methods and access favourites with ease even with gloves on. Suitable for the lab or the field Whether you are working from a laboratory benchtop or out in the field, the HI-802 Iris is an ideal solution. This versatile spectrophotometer includes a rechargeable lithium-ion battery that provides charge for approximately 3,000 measurements before recharging is required, with a size and weight that makes portability easy.

Practical part replacement The HI-802 Spectrophotometer is designed with a tungsten-halogen light for greater energy efficiency, longer service life and improved light quality across our wide wavelength range. Replacement lamps are shipped directly to you, pre-aligned and ready to be installed, with no need to send your whole spectrophotometer to use for replacement. Easy, universal data transfer The Hanna Iris has the capacity for up to 9,999 data points, allowing a large amount of measurements to be stored within the spectrophotometer before transfer is required.

Directly connect to a Mac or PC or transfer data with a USB drive. All data is available in universal PDF and CSV file formats, with no requirement for specialist software. UPDATE for existing users: There is a new reagent addition and method for Total Phosphorus and Cationic surfactants available.

If you want to use this reagent addition method, download the firmware here and click on the Software icon. Scroll down to the update required for the HI-801 or HI-802 Iris. If you need any help with installation, please call our Lab team for more information.

The original testing method for these parameters is still available if you prefer to test that way. Book a demonstration of the Iris Spectrophotometer from Hanna Instruments today.

About Hanna Barcode Reagents Hanna’s barcode reagents are an ideal solution for easy testing in combination with the HI-802 Iris Spectrophotometer. From COD testing to surfactant measurement, our range of reagent vials is fully compatible with our spectrophotometer with instant method recognition following setup. Browse our range of reagents online here.

For reagent skus - please see Specification for each individual parameter. FAQs What industries is Iris suitable for? Hanna’s Iris Spectrophotometer is a versatile option suited to a wide range of industries with different regulatory requirements.

The comprehensive wavelength range and functionality of this portable meter make it an excellent choice for wastewater measurement in laboratories, industrial applications and environmental testing. Can the Iris be customised to my requirements?

Our in-house team preprograms each Iris Spectrophotometer before it is shipped to meet the unique requirements of our customers. This includes adding your most applicable methods to the favourites menu for effortless testing. Our experts can offer any training and support you need to make the most of the Iris.

Can I book training for spectrophotometers? Our team of specialists can provide complete training on the purchase of an Iris Spectrophotometer if required.

Is the Iris Spectrophotometer portable? The Iris has a compact footprint and is easy to carry thanks to these dimensions, allowing it to fit into a dedicated backpack for on-site testing.

This spectrophotometer also has a lithium-ion battery for complete portability, with no need for direct power connection to operate anywhere, from out in the field to in-lab testing. How big is the Iris Spectrophotometer? The Iris has dimensions of 155 x 205 x 322 mm.

This spectrophotometer weighs 3kg (6.6 lbs), allowing it to be carried to different places for testing. This includes the battery, providing a full testing solution that is portable and compact enough to fit anywhere on a benchtop. What reagents should you use with the Iris?

Hanna has a full range of vial reagents for use with the HI-802 Iris, in addition to powder reagents for specific tests. Barcode vials are available for convenient testing, with the Iris scanning the barcode to start the testing process with no additional navigation required. Our comprehensive range includes COD reagents, surfactant reagents and reagents for a wide range of common tests.

How do I book a demonstration of the HI-802 Iris? Contact our specialists directly to book a demonstration of the Iris.

We can offer online video demonstrations for our advanced spectrophotometer to suit your busy schedule. How do I contact Hanna Instruments UK?

Specifications

ParameterValue
SKUHI802-02
Wavelength Range340 to 900 nm
Wavelength Resolution1 nm
Wavelength Accuracy±1.5 nm
Photometric Range0.000 to 3.000 Abs
Photometric Accuracy5mAbs at 0.000 to 0.500 Abs. 1% at 0.500 to 3.000 Abs
Measurement ModesTransmittance (%), Absorbance (abs), Concentration
Sample Cell10 mm square, 50 mm rectangular, 16 mm round, 22 mm round, 13 mm vial
Wavelength Selectionautomatic, based on the selected method (editable for user methods only)
Light Sourcetungsten halogen lamp
Optical Systemsplit beam
Wavelength CalibrationInternal, automatic at power-on, visual feedback
Stray LightSmaller than % T at 340nm with NaNO 2
Spectral bandwidth5 nm
Number of methodsUp to 150 factory (100 pre-loaded); up to 100 user
Data Points StoredUp to 9999 measured values
Export Capability.csv file format, .pdf file format
Connectivity(1) USB - A (mass storage host); (1) USB - B (mass storage device)
Battery Type / Life3000 measurements or 8 hours
Power Supply15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Environment0 to 50 °C (32 to 122 °F); 0 to 95% RH
Dimensions155 x 205 x 322 mm
Weight3 kg (6.6 lbs)
Ordering InformationHI-802 is supplied with 22 mm sample cuvette and cap (4), cuvette adapters x 3, cloth for wiping cuvettes, scissors, USB cable, 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate, quick reference guide with QR code for manual download
AccessoriesHI-7408018 replacement 13 mm vial adapter with barcode reader HI-7408011 replacement 16mm vial adapter HI-7408012 replacement 10mm vial adapter HI-7408014 replacement Tungsten-Halogen lamp HI-7408015 replacement battery
ALKALINITY
Range0 to 500 mg/L (as CaCO 3 )
Resolution1 mg/L
Accuracy (@25°C)±5 mg/L ±5% of reading
Cuvette Type22mm diameter
MethodBromocresol Green
Wavelength610 nm
Reagent CodeHI-775-26
ALKALINITY, MARINE
ALUMINIUM
AMMONIA, LOW RANGE
AMMONIA, LOW RANGE 13mm Vial
AMMONIA, MEDIUM RANGE
AMMONIA, HIGH RANGE
BROMINE
CALCIUM
CALCIUM, MARINE
CHEMICAL OXYGEN DEMAND, LOW RANGE, EPA 13mm Vial
CHEMICAL OXYGEN DEMAND, LOW RANGE, Mercury Free 13mm Vial
CHEMICAL OXYGEN DEMAND, LOW RANGE, ISO 13mm Vial
CHEMICAL OXYGEN DEMAND, MEDIUM RANGE, EPA 13mm Vial
CHEMICAL OXYGEN DEMAND, MEDIUM RANGE, Mercury Free 13mm Vial
CHEMICAL OXYGEN DEMAND, MEDIUM RANGE, ISO 13mm Vial
CHEMICAL OXYGEN DEMAND, HIGH RANGE, EPA 13mm Vial
CHEMICAL OXYGEN DEMAND, ULTRA HIGH RANGE, 13mm Vial
CHLORIDE
CHLORINE DIOXIDE
CHLORINE DIOXIDE (Rapid)
CHLORINE, FREE ULTRA LOW RANGE
CHLORINE, FREE LOW RANGE (powder reagent)
CHLORINE, FREE LOW RANGE (liquid reagent)
CHLORINE, FREE HIGH RANGE
CHLORINE, TOTAL ULTRA LOW RANGE
CHLORINE, TOTAL LOW RANGE (Powder reagent)
CHLORINE, TOTAL LOW RANGE (Liquid reagent)
CHLORINE, TOTAL HIGH RANGE
CHLORINE, TOTAL ULTRA HIGH RANGE
CHROMIUM (VI), LOW RANGE
CHROMIUM (VI), HIGH RANGE
CHROMIUM (VI)/TOTAL (13mm Vial)
COLOUR ADMI LOW RANGE
COLOUR ADMI HIGH RANGE
COLOUR OF WATER
COPPER, LOW RANGE
COPPER, HIGH RANGE
CYANIDE
CYANURIC ACID
FLUORIDE, LOW RANGE
FLUORIDE, HIGH RANGE
HARDNESS, CALCIUM
HARDNESS, MAGNESIUM
HARDNESS, TOTAL LOW RANGE
HARDNESS, TOTAL MEDIUM RANGE
HARDNESS, TOTAL HIGH RANGE
HYDRAZINE
IODINE
IRON, LOW RANGE
IRON, HIGH RANGE
IRON (II) (Ferrous)
IRON (13 mm vial)
IRON TOTAL (13mm vial)
MAGNESIUM
MANGANESE, LOW RANGE
MANGANESE, HIGH RANGE
MAPLE SYRUP
MOLYBDENUM
NICKEL, LOW RANGE
NICKEL, HIGH RANGE
NITRATE
NITRATE, CHROMOTROPIC ACID (13mm vial)
NITRITE, MARINE ULTRA LOW RANGE
NITRITE, MARINE (13mm Vial)
NITRITE, LOW RANGE
NITRITE, LOW RANGE (13mm Vial)
NITRITE, MEDIUM RANGE (13mm Vial)
NITRITE, HIGH RANGE
NITROGEN, TOTAL LOW RANGE (13mm vial)
NITROGEN, TOTAL HIGH RANGE (13mm vial)
OXYGEN, DISSOLVED
OXYGEN SCAVENGERS (CARBOHYDRAZIDE)
OXYGEN SCAVENGERS (DIETHYLHYDROXYLAMINE)(DEHA)
OXYGEN SCAVENGERS (HYDROQUINONE)
OXYGEN SCAVENGERS (ISO-ASCORBIC ACID)
OZONE
pH
PHENOLS
PHOSPHATE, LOW RANGE
PHOSPHATE, HIGH RANGE
PHOSPHORUS, ACID HYDROLYZABLE (13mm vial)
PHOSPHORUS, REACTIVE LOW RANGE (13mm vial)
PHOSPHORUS, REACTIVE HIGH RANGE (13mm vial)
PHOSPHORUS, TOTAL LOW RANGE (13mm vial)
PHOSPHORUS, TOTAL HIGH RANGE (13mm vial)
PHOSPHORUS, MARINE ULTRA LOW RANGE
POTASSIUM, LOW RANGE
POTASSIUM, MEDIUM RANGE
POTASSIUM, HIGH RANGE
SILICA, LOW RANGE
SILICA, HIGH RANGE
SILVER
SULPHATE
SURFACTANTS, ANIONIC
SURFACTANTS, ANIONIC 13mm vial
SURFACTANTS, CATIONIC (13mm vial)
SURFACTANTS, NONIONIC (13mm vial)
ZINC

Accessories

  • HI-7408020: HI-7408020 Protective Dust Cover for the HI-80X series of Spectrophotometers
  • HI-7408014: HI-7408014 Replacement Tungsten Halogen Lamp for Iris Spectrophotometers